JBL ES 150PW (serv.man5) EMC - CB Certificate ▷ View online
Page 14 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………..:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………..:
Primary – secondary:
TT0900901830-E: >10mm
TT0900901830-E: >10mm
Primary – secondary:
TD-230-0300A+C/TD-230-
0300A+A: >10mm
TD-230-0300A+C/TD-230-
0300A+A: >10mm
TR1: >10mm
P
Coil formers and partition walls > 0,4 mm
Main transformer: Thin sheet
insulation
TR1: Sec winding is TIW
insulation
TR1: Sec winding is TIW
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Iron core is floating (main transf
and TR1)
and TR1)
N/A
Coil formers and partition walls > 0,4 mm
N/A
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
(see appended table)
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
P
Protective devices used within their ratings
P
Page 15 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ...:
T2.0AL/250V (ES150P/230)
T2.0AL/250V (ES150PW/230)
T2.0AL/250V (ES150PW/230)
On standby PCB:
FUSE T250mA L/250V
FUSE T250mA L/250V
P
14.5.2.3
Not possible to connect fuses in parallel ................:
No
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
Tools are required
P
14.5.3
PTC thermistors comply with IEC 60730-1
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
P
14.6
Switches
(see appended table)
P
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Mains switch: 48..4A (measured
peak surge current)
peak surge current)
Mains relay K1: 40.6 A
(measured peak surge current)
(measured peak surge current)
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
1 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
Page 16 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices and the like
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
P
Optocouplers comply with Cl. 8
OP1 (on standby PCB)
P
P
14.12
Surge suppression varistors
RV1 (after fuse)
N/A
Page 17 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Comply with IEC 61051-2
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Mains plug, appliance inlet
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
data
P
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video - outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
with separate protective earth terminal near mains
input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ...................: N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords
N/A
Not soldered to conductors of a printed circuit board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A