DOWNLOAD JBL ES 150PW (serv.man5) Service Manual ↓ Size: 6.22 MB | Pages: 84 in PDF or view online for FREE

Model
ES 150PW (serv.man5)
Pages
84
Size
6.22 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
es-150pw-sm5.pdf
Date

JBL ES 150PW (serv.man5) EMC - CB Certificate ▷ View online

 
Page 10 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 P 
9.1.1.1 
a) Open circuit voltages  
 
 
b) Touch current measured from terminal devices 
using the network in 
annex D …………………………: 
Voltage U1: 0.056V pk 
Voltage U2: 0.056V pk 
Alternatively – Measured 
Current 
 
c) Discharge not exceeding 45 μC  
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
 N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s ………………:
0V<2s P 
 
If C is not greater than 0,1 μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
250N 
9.2 
No hazard after removing a cover by hand  
 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation .................................................................: 
 N/A 
10.2 
Humidity treatment 48 h or 120 h ...........................: 
48 h and 120 h 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 
 
Page 11 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
 P 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 P 
 
11 Fault 
conditions 
 
11.1 
No shock hazard under fault condition  
 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
 
 
No hazard from softening solder  
 
 
Soldered terminations not used  as protective 
mechanism  
 P 
11.2.1 
Measurement of temperature rises  
(see appended table) 
11.2.2 
Temperature rise of accessible parts  
(see appended table) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation  
(see appended table) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min  
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² 
………: 
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min  
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 N/A 
 
Class I protective earthing maintained  
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
 P 
11.2.5 
Temperature rise of windings  
(see appended table) 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5  
(see appended table) 
 
12 Mechanical 
strength 
 
12.1.1 
Bump test where mass >7 kg  
15.5kg 
12.1.2 
Vibration test  
No connection or part that might 
impair safety can become loose 
12.1.3 
Impact hammer test  
 
 
Page 12 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Steel ball test  
 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg    
N/A 
12.1.5 
Thermoplastic enclosures stress relief test  
 
12.2 
Fixing of knobs, push buttons, keys and levers  
 
12.3 
Remote controls with hazardous live parts  
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
 
N/A 
12.6 
Telescoping or rod antennas construction  
ES150PW/230:  
Antenna ball end Ø=7.5mm 
12.6.1 
Telescoping or rod antennas securement  
20N 
 
13 
Clearances and creepage distances 
 
13.1 
Clearances in accordance with 13.3  
 
 
Creepage distances in accordance with 13.4  
 
13.2 
Determination of operating voltage  
 
13.3 Clearances 
 
 
13.3.1 General 
 
 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9  ............: 
 P 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
Circuits not conductively 
connected to the mains cannot 
cause any shock hazard 
N/A 
13.3.4 
Measurement of transient voltages  
 
N/A 
13.4 
Creepage distances  
 
 
Creepage distances greater than table 11 minimum 
values  
 P 
13.5 
Printed boards  
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 13.3 
and 13.4  
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
Page 13 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
13.7 
Enclosed, enveloped or hermetically sealed parts not 
conductively connected to the mains, clearances and 
creepage distances as in table 12  
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 N/A 
 
14 Components 
 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
 N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
 N/A 
 
Resistors separately approved ……………………….:  
N/A 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved ……………………:  Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition ...: 
Y1: C03 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ...: 
X2: C19, C06 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ......................: 
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better  ..................: 
 N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better  ................................................: 
 N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ........................................................................: 
 N/A 
14.3 
Inductors and windings  
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
Transtec 
TT0900901830-E 
Huizhou GP Wiring Technology
 
TD-230-0300A+C 
TD-230-0300A+A 
Standby transformer TR1: 
 DW KB1157-11486 
 
Transformers and inductors separately approved .: 
No 
N/A 
14.3.2 General 
 
 
 
Insulation material complies with clause 20.1.4  
 
Page of 84
Display