Page 18 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
Wire secured by additional means to the  
conductor   
 N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
 N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
 N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16    N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 N/A 
15.4 
Devices forming a part of the mains plug  
 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................: 
PVC  
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
 N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
 P 
 
Page 19 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
 N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2) 
 N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
 N/A 
16.5 
Adequate strain relief on external flexible cords  
Appliance inlet 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor  
 N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement in 
use  
 N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
 N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 N/A 
 
17 Electrical 
connections 
and mechanical fixings 
 
17.1 
Torque test to table 20  
 
 
- screws into metal: 5 times  
 
N/A 
 
- screws into non-metallic material: 10 times  
 
17.2 
Correct introduction into female threads in non-
metallic material  
 P 
17.3 
Cover fixing screws: captive  
 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
 P 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
 N/A 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
 N/A 
 
Page 20 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder  
 N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
 N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
 N/A 
17.9 
 P 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
 
Picture tube separately approved to IEC 61965 ....: 
 
N/A 
 
Picture tube separately approved to 18.1 . .............: 
 
N/A 
18.1 
Picture tubes >16 cm intrinsically protected  
 
N/A 
 
Non-intrinsically protected tubes >16 cm used with 
protective screen  
 N/A 
 
Protective film as part of implosion protection: edges 
covered by enclosure  
 N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples  
 
N/A 
18.2.1 
Samples subject to ageing: 6 samples  
 
N/A 
18.2.2 
Samples subject to implosion test: 6 samples  
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 samples  
 N/A 
18.3 Non-intrinsically 
protected tubes tested to 18.3  
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 7 kg . ................: 15.5kg 
 
Apparatus intended to be fastened in place – 
suitable instructions ................................................: 
 N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
 
19.2 
100 N force applied vertically downwards  
 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability  
 N/A 
19.4 
Edges or corners not hazardous  
 
19.5 
Glass surfaces (exclaminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1  
 N/A 
19.6 
Wall or ceiling mountings adequate  
 
N/A 
 
Page 21 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 N/A 
 
b) Exemption for small components as defined in 
20.1  
 P 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4  
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
 N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure  
V-0 P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
 N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the 
distances in Table 21 comply with the relevant 
flammability category in Table 21  
(see appended table) 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 N/A 
20.2.2 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 N/A 
 