JBL ES 150PW (serv.man5) EMC - CB Certificate ▷ View online
Page 34 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Components in ES150PW/230 which differs from ES150P/230
Mains
transformer
T501
transformer
T501
Huizhou GP
Wiring
Technology
TD-230-0300A+A
230V / 50Hz
IEC 60065
—
*) Thermal cut-
out
out
Seki ST-22
5A 250V 130
°C
IEC 60730
Plastic cover
(core insulation
in transformer)
(core insulation
in transformer)
EI Dupont De
Nemours
Various material
designations in
UL file E41938
Thickness
0.8mm
Min HB75
IEC 60707
HB75
-
Appliance inlet
with fuse holder
with fuse holder
Chily 3528-T7C02B06
10A
250V IEC
60320
Mains Cord
for UK
for UK
Hua-run
Electrical
Industrial
Industrial
D103-472
2 x 0.75mm
2
IEC 60227
Kema
Pre PCB
Gofortune
CEM-1
Mother PCB
Jin He
A126
Class D PCB
Hsiang Kuo
FR-4
EQ PCB ID SW
Chih Hsien
FR-1
RX PCB
Luen Tai
FR-4
V-0
IEC 60707
V-1
—
*) Did not open during fault conditions.
Page 35 of 58
Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according ....................: EN 60065:2002 + A1:2006
Attachment Form No......................: EU_GD_IEC60065J_I
Attachment Form Originator.............: Intertek Semko AB
Master Attachment Form..................: 2009-06
Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according ....................: EN 60065:2002 + A1:2006
Attachment Form No......................: EU_GD_IEC60065J_I
Attachment Form Originator.............: Intertek Semko AB
Master Attachment Form..................: 2009-06
Copyright © 2009 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN)
Clause
Requirement + Test
Result - Remark
Verdict
Contents
Add the following annexes:
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated with portable audio
equipment – Maximum sound pressure level
measurement methodology and limit considerations –
Part 1: General
method for ”one package equipment”, and in EN 50332-
2, Sound system equipment: Headphones and
earphones associated with portable audio equipment –
Maximum sound pressure level measurement
methodology and limit considerations – Part 2:
Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated with portable audio
equipment – Maximum sound pressure level
measurement methodology and limit considerations –
Part 1: General
method for ”one package equipment”, and in EN 50332-
2, Sound system equipment: Headphones and
earphones associated with portable audio equipment –
Maximum sound pressure level measurement
methodology and limit considerations – Part 2:
Guidelines to
associate sets with headphones coming from different
manufacturers.
N/A
4.1.1
Replace the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
50333
.
P
5.1.i)
Add the following note:
NOTE For RATED POWER CONSUMPTION
measurements of TVs reference is made to EN 60107.
measurements of TVs reference is made to EN 60107.
N/A
Page 36 of 58
Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
6.1
Replace the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
N/A
13.3.1
Delete note 4.
P
14
Delete note 4 and note 5.
P
15.1.1
Delete notes 1 and 2.
P
15.2
Delete note 2.
P
16.1
Delete note 1.
P
16.2
Delete the note.
P
20
Delete note 2.
P
Page 37 of 58
Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
P
Annex G
Delete the note.
P
Annex J.2 Delete the notes of Table J.1.
P
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
For ROUTINE TEST reference is made to EN
50333.
P
Bibliography
Add the following standards:
EN 60332-1: 2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for “one package equipment”.
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for “one package equipment”.
PrEN 50332-2 (under consideration), Sound system equipment: Headphones and
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology and
limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology and
limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
Add the following notes for the standards indicated:
IEC 60130
NOTE
Parts 9 and 17: 1998 are harmonized as Ens (not modified).
IEC 60169
NOTE
Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE
Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56
NOTE
Harmonized as EN 60335-2-56: 1997 (not modified).
IEC 60335-2-82
NOTE
Harmonized as EN 60335-2-82: 2000 (not modified).
IEC 60695
NOTE
Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE
Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1
NOTE
Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4
NOTE
Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6
NOTE
Harmonized as EN 61558-2-6: 1997 (not modified).
N/A