- Page 37 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
3.2.5.1
C: Replace
"60245 IEC 53" by "H05 RR-F";
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
"60227 IEC 52" by "H03 VV-F or H03 VVH2-F";
"60227 IEC 53" by "H05 VV-F or H05 VVH2-F2".
In Table 3B, replace the first four lines by the
following:
following:
Up to and including 6
0,75
1)
Over 6 up to and including 10 (0,75)
2)
1,0
Over 10 up to and including 16 (1,0)
3)
1,5
In the Conditions applicable to Table 3B delete the
words "in some countries" in condition
words "in some countries" in condition
1)
.
In Note 1, applicable to Table 3B, delete the
second sentence.
second sentence.
Class III equipment.
N/A
3.2.5.1
S (GB): A power supply cord with conductor of
1,25 mm
1,25 mm
2
is allowed for equipment with a rated
current over 10 A and up to and including 13 A.
Class III equipment.
N/A
3.3.4
C: In Table 3D, delete the fourth line: conductor
sizes for 10 to 13A, and replace with the following:
sizes for 10 to 13A, and replace with the following:
Over 10 up to and including 16 1,5 to 2,5 1,5 to 4
Delete the fifth line: conductor sizes for 13 to
16 A.
16 A.
Class III equipment.
N/A
3.3.4
S (GB): The range of conductor sizes of flexible
cords to be accepted by terminals for equipment
with a
cords to be accepted by terminals for equipment
with a
RATED CURRENT
of over 10 A up to and
including 13 A is:
- 1,25 mm
- 1,25 mm
2
to 1,5 mm
2
nominal cross-sectional
area.
Class III equipment.
N/A
4.3.6
S (GB): The torque test is performed using a
socket outlet complying with BS 1363 and the plug
part of
socket outlet complying with BS 1363 and the plug
part of
DIRECT PLUG
-
IN EQUIPMENT
shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125
12.9, 12.11, 12.12, 12.16 and 12.17, except that
the test of 12.17 is performed at not less than
125
°
C.
Not a Direct Plug-In Equipment.
N/A
S (IE): D
IRECT PLUG
-
IN EQUIPMENT
is known as plug
similar devices. Such devices shall comply with
Statutory Instrument 526:1997 – National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.
Statutory Instrument 526:1997 – National
Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.
Not a Direct Plug-In Equipment.
N/A
4.3.13.6
C: Add the following note:
NOTE Attention is drawn to 1999/519/EC: Council
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation are currently under
development.
Recommendation on the limitation of exposure of the general
public to electromagnetic fields 0 Hz to 300 GHz. Standards
taking into account this Recommendation are currently under
development.
No radiation.
N/A
- Page 38 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
6.1.2.1
S (FI, NO, SE): Add the following text between the
first and second paragraph:
first and second paragraph:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES
and
CREEPAGE DISTANCES
do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and
in addition
accordance with the compliance clause below and
in addition
- passes the tests and inspection criteria of 2.10.8
with an electric strength test of 1,5 kV multiplied
by 1,6 (the electric strength test of 2.10.7 shall be
performed using 1,5 kV), and
with an electric strength test of 1,5 kV multiplied
by 1,6 (the electric strength test of 2.10.7 shall be
performed using 1,5 kV), and
- is subject to
ROUTINE TESTING
for electric strength
during manufacturing, using a test voltage of
1,5 kV.
1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to
EN 132400:1994, may bridge this insulation under
the following conditions:
EN 132400:1994, may bridge this insulation under
the following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950:2000, 6.2.2.1;
having a capacitor classified Y3 as defined by
EN 132400, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in
EN 60950:2000, 6.2.2.1;
- the additional testing shall be performed on all
the test specimens as described in EN 132400;
the test specimens as described in EN 132400;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
before the endurance test in EN 132400, in the
sequence of tests as described in EN 132400.
No TNV circuits.
N/A
- Page 39 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
6.1.2.2
S (FI, NO, SE): The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT
and
PLUGGABLE EQUIPMENT TYPE
B and equipment
intended to be used in a
RESTRIC TED ACCESS
LOCATION
where equipotential bonding has been
applied, e.g. in a telecommunication centre, and
which has provision for a permanently connected
which has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR
and is provided
with instructions for the installation of that
conductor by a service person.
conductor by a service person.
No TNV circuits.
N/A
7.1
S (FI, NO, SE): Requirements according to this
annex, 6.1.2.1 and 6.1.2.2 apply with the term
annex, 6.1.2.1 and 6.1.2.2 apply with the term
TELECOMMUNICATION NETWORK
in 6.1.2 being
replaced by the term
CABLE DISTRIBUTION SYSTEM
.
Not for connection to cable
distrubution systems.
distrubution systems.
N/A
G.2.1
S (NO): Due to the IT power distribution system
used (see annex V, Fig. V.7), the
used (see annex V, Fig. V.7), the
A
.
C
.
MAINS
SUPPLY
voltage is considered to be equal to the
line-to-line voltage, and will remain at 230 V in
case of a single earth fault.
case of a single earth fault.
Class III equipment..
N/A
Annex H
C: Replace the last paragraph of this annex by:
At any point 10 cm from the surface of the
OPERATOR ACCESS AREA
, the dose rate shall not
exceed 1
µ
Sv/h (0,1 mR/h) (see note). Account is
taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.
Delete Note 2.
The unit does not emit X-ray
radiation.
radiation.
N/A
Annex H
A (DE, Regulation on protection against hazards
by X-ray, of 8
by X-ray, of 8
th
January 1987, Article 5
[Operation of X-ray emission source], clauses 1
to 4):
to 4):
a) A licence is required by those who operate an
X-ray emission source.
X-ray emission source.
b) A licence in accordance with clause 1 is not
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
required by those who operate an X-ray emission
source on which the electron acceleration voltage
does not exceed 20 kV if
1) the local dose rate at a distance of 0,1 m
from the surface does not exceed 1 µSv/h and
from the surface does not exceed 1 µSv/h and
2) it is adequately indicated on the X-ray
emission source that
emission source that
i) X-rays are generated, and
ii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
exceed the maximum value stipulated by the
manufacturer or importer.
c) A licence in accordance with clause 1 is also
German A deviation withdrawn
according to Amd. A11:2004.
according to Amd. A11:2004.
N/A
- Page 40 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
not required by persons who operate an X-ray
emission source on which the electron
acceleration voltage exceeds 20 kV if
emission source on which the electron
acceleration voltage exceeds 20 kV if
1) the X-ray emission source has been granted
a type approval, and
a type approval, and
2) it is adequately indicated on the X-ray
emission source that
emission source that
i) X-rays are generated
ii) the device stipulated by the manufacturer or
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
importer guarantees that the maximum
permissible local dose rate in accordance with
the type approval is not exceeded, and
iii) the electron acceleration voltage must not
exceed the maximum value stipulated by the
manufacturer or importer.
exceed the maximum value stipulated by the
manufacturer or importer.
d) Furthermore, a licence in accordance with
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
clause 1 is also not required by persons who
operate X-ray emission sources on which the
electron acceleration voltage does not exceed
30 kV if
1) the X-rays are generated only by intrinsically
safe CRTs complying with Enclosure III, No. 6,
safe CRTs complying with Enclosure III, No. 6,
2) the values stipulated in accordance with
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
Enclosure III, No. 6.2 are limited by technical
measures and specified in the device, and
3) it is adequately indicated on the X-ray
emission source that the X-rays generated are
adequately screened by the intrinsically safe CRT.
emission source that the X-rays generated are
adequately screened by the intrinsically safe CRT.
Annex P
C: Replace the text of this annex by:
See annex ZA.
—
Annex Q
C: Replace the title of IEC 61032 by "Protection of persons and equipment by
enclosures – Probes for verification".
enclosures – Probes for verification".
Add the following notes for the standards indicated:
—