- Page 33 of 51 - 
 
 
 
www.nemko.com
 
Report No.  27772 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
plug, must be provided with a visible tag with the 
following text: 
Vigtigt! 
Lederen med grøn/gul isolation må kun tilsluttes en 
klemme mærket 
 
 eller  
  
If essential for the safety of the equipment, the tag 
must in addition be provided with a diagram which 
shows the connection of the other conductors, or 
be provided with the following text: "For tilslutning 
af de øvrige ledere, se medfølgende 
installationsvejledning." 
1.7.5 
S (DK): Socket-outlets for providing power to 
other equipment shall be in accordance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, 
when used on Class I equipment. For 
STATIONARY
 
EQUIPMENT
 the socket-outlet shall be in 
accordance with Standard Sheet DK 1-1b or 
DK 1-5a. 
There are no socket outlets 
providing power to other 
appliances. 
 
N/A 
1.7.5 
A (DK, Heavy Current Regulations): 
CLASS
 II 
EQUIPMENT
 shall not be fitted with socket-
outlets for providing power to other equipment.  
Class III equipment.
 
N/A 
1.7.12 
A (DE, Gesetz über technische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des Gerätesicherheits-
gesetzes" [General administrative regulation on 
the execution of the Second Section of the 
Equipment safety law], of 10
th
 January 1996, 
article 2, 4
th
 paragraph item 2).  
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even only by service 
personnel are not exempted.  
Must be considered before 
marketing in Germany.
 
— 
1.7.15 
A (CH, Ordinance on environmentally hazardous 
substances SR 814.013): 
Annex 4.10 of SR 814.013 applies for batteries. 
There is  no battery containing 
Cd or Hg in the equipment.
 
N/A 
 
 
- Page 34 of 51 - 
 
 
 
www.nemko.com
 
Report No.  27772 
 
 
TRF No.:IECEN60950_1B 
 
 
2.2.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV circuits.
 
N/A 
2.3.2 
S (NO): Requirements according to this annex, 
6.1.2.1 apply. 
No TNV circuits.
 
N/A 
2.3.3 and 
2.3.4 
S (NO): Requirements according to this annex, 
1.7.2 and 6.1.2.1 apply. 
No TNV circuits.
 
N/A 
2.6.3.3 
S (GB): The current rating of the circuit shall be 
taken as 13 A, not 16 A. 
Class III equipment.
 
N/A 
2.7.1 
C: Replace the subclause as follows:  
Basic requirements 
To protect against excessive current, short-
circuits and earth faults in 
PRIMARY CIRCUITS
protective devices shall be included either as 
integral parts of the equipment or as parts of the 
building installation, subject to the following, a), b) 
and c): 
a) except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as parts of 
the equipment; 
b) for components in series with the mains input to 
the equipment such as the supply cord, appliance 
coupler, r.f.i. filter and switch, short-circuit and 
earth fault protection may be provided by 
protective devices in the building installation; 
c) it is permitted for 
PLUGGABLE EQUIPMENT TYPE
 B 
or 
PERMANENTLY CONNECTED EQUIPMENT
, to rely on 
dedicated overcurrent and short-circuit protection 
in the building installation, provided that the means 
of protection, e.g. fuses or circuit breakers, is 
fully specified in the installation instructions.  
If reliance is placed on protection in the building 
installation, the installation instructions shall so 
state, except that for 
PLUGGABLE EQUIPMENT  TYPE 
the building installation shall be regarded as 
providing protection in accordance with the rating 
of the wall socket outlet. 
Class III equipment.
 
N/A 
 
S (GB): To protect against excessive currents and 
short-circuits in the 
PRIMARY CIRCUIT 
of
 DIRECT 
PLUG
-
IN EQUIPMENT
, protective devices shall be 
included as integral parts of the 
DIRECT PLUG
-
IN 
EQUIPMENT
Not a Direct Plug-In Equipment.
 
N/A 
2.7.2 
C: Void. 
 
 
 
 
- Page 35 of 51 - 
 
 
 
www.nemko.com
 
Report No.  27772 
 
 
TRF No.:IECEN60950_1B 
 
2.10.2 
C: Replace in the first line "(see also 1.4.7)" by 
"(see also 1.4.8)". 
Class III equipment.
 
N/A 
2.10.3.1 
S (NO): Due to the IT power distribution system 
used (see annex V, Fig. V.7), the 
A
.
C
.  
MAINS 
SUPPLY
 voltage is considered to be equal to the 
line-to-line voltage and will remain at 230 V in 
case of a single earth fault.  
Class III equipment.
 
N/A 
3.2.1.1 
S (CH): Supply cords of equipment having a 
RATED CURRENT
 not exceeding 10 A shall be 
provided with a plug complying with SEV 1011 or 
IEC 60884-1 and one of the following dimension 
sheets: 
SEV 6532-2.1991, Plug Type 15, 3P+N+PE   250/400 V, 10 A 
SEV 6533-2.1991, Plug Type 11, L+N 
250 V, 10 A 
SEV 6534-2.1991, Plug Type 12, L+N+PE 
250 V, 10 A 
In general, EN 60309 applies for plugs for 
currents exceeding 10A. However, a 16 A plug 
and socket-outlet system is being introduced in 
Switzerland, the plugs of which are according to 
the following dimension sheets, published in 
February 1998: 
SEV 5932-2.1998, Plug Type 25, 3L+N+PE   230/400 V, 16 A 
SEV 5933-2.1998, Plug Type 21, L+N 
250 V, 16 A 
SEV 5934-2.1998, Plug Type 23, L+N+PE 
250 V, 16 A
 
Class III equipment.
 
N/A 
 
S (DK): Supply cords of single-phase equipment 
having a rated current not exceeding 13 A shall be 
provided with a plug according to the Heavy 
Current Regulations, Section 107-2-D1. 
C
LASS 
EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with 
standard sheet DK 2-1a or DK 2-5a. 
If poly -phase equipment and single -phase 
equipment having a 
RATED CURRENT
 exceeding 
13 A is provided with a supply cord with a plug, 
this plug shall be in accordance with the Heavy 
Current Regulations, Section 107-2-D1 or 
EN 60309-2. 
Class III equipment.
 
N/A 
 
 
- Page 36 of 51 - 
 
 
 
www.nemko.com
 
Report No.  27772 
 
 
TRF No.:IECEN60950_1B 
 
 
S (ES): Supply cords of single-phase equipment 
having a rated current not exceeding 10 A shall be 
provided with a plug according to 
UNE 20315:1994. 
Supply cords of single-phase equipment having a 
rated current not exceeding 2,5 A shall be 
provided with a plug according to 
UNE-EN 50075:1993. 
C
LASS 
EQUIPMENT
 provided with socket-outlets 
with earth contacts or which are intended to be 
used in locations where protection against indirect 
contact is required according to the wiring rules, 
shall be provided with a plug in accordance with 
standard UNE 20315:1994. 
If poly -phase equipment is provided with a supply 
cord with a plug, this plug shall be in accordance 
with UNE-EN 60309-2. 
Class III equipment.
 
N/A 
 
S (GB): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to BS 1363 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 'standard plug' in accordance with 
Statutory Instrument 1768:1994 – The Plugs and 
Socket etc. (Safety) Regulations 1994, unless 
exempted by those regulations. 
NOTE – 'Standard plug' is defined in SI 1768:1994 and 
essentially means an approved plug conforming to BS 1363 or 
an approved conversion plug. 
 
Class III equipment.  
 
N/A 
 
S (IE): Apparatus which is fitted with a flexible 
cable or cord and is designed to be connected to 
a mains socket conforming to I.S. 411 by means 
of that flexible cable or cord and plug, shall be 
fitted with a 13 A plug in accordance with 
Statutory Instrument 525:1997 – National 
Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic Use) 
Regulations 1997. 
Class III equipment.
 
N/A 
3.2.3 
C: Delete Note 1 and in Table 3A, delete the 
conduit sizes in parentheses. 
 
 