JBL ENCOUNTER (serv.man4) EMC - CB Certificate ▷ View online
- Page 21 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
4.2.5
Impact test
Refer below:
—
Fall test
—
Swing test
—
4.2.6
Drop test
Drop test not applicable.
N/A
4.2.7
Stress relief test
No risk of shrinkage or distortion
on enclosures due to release of
internal stresses.
on enclosures due to release of
internal stresses.
N/A
4.2.8
Cathode ray tubes
CRT not used in the equipment.
N/A
Picture tube separately certified........................ :
—
4.2.9
High pressure lamps
No high pressure lamps in the
equipment.
equipment.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) .... :
Not intended to be mounted on a
wall or ceiling.
wall or ceiling.
N/A
4.3
Design and construction
—
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) .............:
Class III equipment, no
hazardous voltages.
hazardous voltages.
P
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
Class III equipment, no
hazardous voltages.
hazardous voltages.
N/A
4.3.5
Connection of plugs and sockets
SELV connectors do not comply
with IEC 60320 or IEC 60083.
with IEC 60320 or IEC 60083.
P
4.3.6
Direct plug-in equipment
Not intended to plug directly into
a wall socket-outlet.
a wall socket-outlet.
N/A
Dimensions (mm) of mains plug for direct plug-in
...................................................................... :
—
Torque and pull test of mains plug for direct plug-in;
torque (Nm); pull (N) ........................................ :
torque (Nm); pull (N) ........................................ :
—
4.3.7
Heating elements in earthed equipment
No heating elements provided.
N/A
4.3.8
Batteries
No batteries in the equipment.
N/A
4.3.9
Oil and grease
Insulation is not exposed to oil,
grease etc.
grease etc.
N/A
4.3.10
Dust, powders, liquids and gases
The equipment does not generate
ionizing radiation or use a laser,
and does not contain flammable
liquids or gases.
ionizing radiation or use a laser,
and does not contain flammable
liquids or gases.
N/A
- Page 22 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
4.3.11
Containers for liquids or gases
No containers for liquids or
gases in the equipment.
gases in the equipment.
N/A
4.3.12
Flammable liquids ............................................:
The equipment does not contain
flammable liquid.
flammable liquid.
N/A
4.3.13
Radiation; type of radiation ..............................:
Refer below:
—
4.3.13.1
General
Refer below:
—
4.3.13.2
Ionizing radiation
The equipment does not generate
ionizing radiation.
ionizing radiation.
N/A
4.3.13.5
Laser (including LEDs)
LED provided is diffused.
N/A
Laser class .....................................................:
—
4.3.13.6
Other types .....................................................:
The equipment does not generate
other types of radiation.
other types of radiation.
N/A
4.4
Protection against hazardous moving parts
—
4.4.1
General
No moving parts.
N/A
4.4.2
Protection in operator access areas
No moving parts.
N/A
4.4.3
Protection in restricted access locations
Not intended for installation in
RAL.
RAL.
N/A
4.4.4
Protection in service access areas
Unintentional contact is not likely
in servic e access areas.
in servic e access areas.
N/A
4.5
Thermal requirements
—
4.5.1
Maximum temperatures
(see appended table 4.5)
P
Normal load condition per Annex L.................... :
P
4.5.2
Resistance to abnormal heat
No thermoplastic parts carrying
hazardous voltages.
hazardous voltages.
N/A
4.6
Openings in enclosures
—
4.6.1
Top and side openings
Class III equipment powered by
Limited Power Source.
Limited Power Source.
P
Dimensions (mm) ........................................... :
35mm diameter.
—
4.6.2
Bottoms of fire enclosures
HB enclosure powered by a
limited power source.
limited power source.
N/A
Construction of the bottom................................ :
—
4.6.3
Doors or covers in fire enclosures
No doors or covers in enclosure.
N/A
4.6.4
Openings in transportable equipment
The unit is not regarded as
transportable equipment.
transportable equipment.
N/A
4.6.5
Adhesives for constructional purposes
No barrier adhesive inside
enclosure.
enclosure.
N/A
- Page 23 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
Conditioning temperature (
°
C)/time (weeks)....... :
—
4.7
Resistance to fire
Class III equipment powered by
Limited Power Source.
Limited Power Source.
—
4.7.1
Reducing the risk of ignition and spread of flame
Class III equipment powered by
Limited Power Source.
Limited Power Source.
N/A
Method 1, selection and application of components
wiring and materials
wiring and materials
N/A
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Refer below:
N/A
4.7.2.1
Parts requiring a fire enclosure
HB enclosure powered by a
limited power source.
limited power source.
N/A
4.7.2.2
Parts not requiring a fire enclosure
HB enclosure powered by a
limited power source.
limited power source.
P
4.7.3
Materials
—
4.7.3.1
General
Components and materials have
adequate flammability
classification.
adequate flammability
classification.
P
4.7.3.2
Materials for fire enclosures
HB enclosure powered by a
limited power source.
limited power source.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
HB enclosure powered by a
limited power source.
limited power source.
P
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
Other materials inside enclosure
are minimum V-2 material.
are minimum V-2 material.
P
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment.
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4kV.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
—
5.1
Touch current and protective conductor current
—
5.1.1
General
Class III equipment.
N/A
5.1.2
Equipment under test (EUT)
N/A
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
Class III equipment.
N/A
5.1.5
Test procedure
—
5.1.6
Test measurements
N/A
Test voltage (V) ..............................................:
—
Measured touch current (mA) ..........................:
—
Max. allowed touch current (mA) ......................:
—
- Page 24 of 51 -
www.nemko.com
Report No. 27772
TRF No.:IECEN60950_1B
Measured protective conductor current (mA) ....:
—
Max. allowed protective conductor current (mA) . :
—
5.1.7
Equipment with touch current exceeding 3.5 mA
......................................................................:
Class III equipment.
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network nor a
cable distribution system.
telecommunication network nor a
cable distribution system.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable distribution
system
telecommunication network and a cable distribution
system
N/A
Test voltage (V) ..............................................:
—
Measured touch current (mA) ..........................:
—
Max. allowed touch current (mA) ......................:
—
5.1.8.2
Summation of touch currents from
telecommunication networks .............................:
telecommunication networks .............................:
N/A
5.2
Electric strength
Class III equipment.
N/A
5.2.1
General
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
—
5.3.1
Protection against overload and abnormal
operation
operation
See the enclosed fault condition
test.
test.
P
5.3.2
Motors
There are no motors in the
equipment.
equipment.
N/A
5.3.3
Transformers
There are no safety
transformers in the equipment.
transformers in the equipment.
N/A
5.3.4
Functional Insulation
Complies with c.
P
5.3.5
Electromechanical components
No electromechanical
components.
components.
N/A
5.3.6
Simulation of faults
See the enclosed fault condition
test.
test.
P
5.3.7
Unattended equipment
No thermostats, temperature
limiters or thermal cut-outs.
limiters or thermal cut-outs.
N/A
Click on the first or last page to see other ENCOUNTER (serv.man4) service manuals if exist.