DOWNLOAD JBL CS Service Manual ↓ Size: 7.26 MB | Pages: 58 in PDF or view online for FREE

Model
CS
Pages
58
Size
7.26 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cs.pdf
Date

JBL CS EMC - CB Certificate ▷ View online

 
Page 6 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0.5 mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  ....:   
N/A 
 
Emission limits under fault conditions ....................:   
N/A 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
any single protective device defeated except those 
of Cl. 7.1 a) and b) 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150
 o
Separately approved 
components. 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools are required. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
Not used. 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
 P 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) 
 N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 P 
 
Components bridging reinforced or double insulation 
complying with 14.1 a) or 14.3 
Transformer P 
 
Page 7 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
This sub-clause is void 
 
N/A 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0.4 mm (mm) ......................................: 
 P 
 
Reinforced insulation > 0.4 mm (mm)  ...................:   
 
Thin sheet insulation used inside the enclosure. 
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 dielectric 
 P 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 dielectric 
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 dielectric 
 P 
 
Reinforced insulation, three layers any two which 
meet 10.3 dielectric 
 N/A 
8.9 
Primary Wiring: Adequate insulation between 
internal hazardous live conductors and accessible 
parts 
Applies to Class 
Ι. 
N/A 
 
Secondary Wiring: Adequate insulation between 
internal hazardous live parts and conductors 
connected to accessible parts 
As above. 
N/A 
8.10 Class 
II 
Wiring: 
(1) Primary: Double insulation between conductors 
connected to the mains and accessible parts. 
(2) Secondary: Double insulation between 
conductors connected to accessible parts and the 
mains 
Mains wires are double 
insulated, no secondary wire 
can come in to contact with un-
insulated mains. 
8.11 
Detaching of wires 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
No risk of any wire becoming 
detached. 
N/A 
 
Vibration test carried out ........................................:  No, no need. See above. 
N/A 
 
Page 8 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
8.12 
This sub-clause is void 
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges (2N force) 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
8.19.1 
Disconnect device 
Mains plug 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
 N/A 
8.19.2 
Mains switch ON indication 
 
N/A 
8.20 Switch 
not 
fitted 
in the mains cord 
 
N/A 
8.21 
Bridging components comply with clause 14 
 
N/A 
8.22 
Test of non-separable thin sheet material 
 
N/A 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1    a)  Determination of Hazardous Live parts 
 
b)  Touch current measured from terminal devices 
using the network in annex D  ................................: 
See table 9 
c)  Discharge not exceeding 45 μC  
N/A 
d)  Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 P 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
 P 
 
Page 9 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
0V<2s P 
 
If C is not greater than 0.1 μF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
b) 
Test hook of fig. 4 for 10 s (20 N) 
 
c) 
Conductive enclosure: 30 mm diameter test tool for 
5 s (100 or 250 N) ..................................................: 
250N P 
9.2 
No hazard 2s after removing a cover by hand 
 
N/A 
 
10 INSULATION 
REQUIREMENTS 
10.1 Insulation 
resistance 
(MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................: 
 N/A 
10.2 
Humidity treatment 48 h or 120 h  ..........................:  48h and 120h   
10.3 
Insulation resistance and dielectric strength 
between mains terminals 
 P 
 
Insulation resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
 N/A 
 
Insulation resistance across REINFORCED 
insulation (Class II) 
 P 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 Heating 
under 
fault 
condition 
 
 
No hazard from softening solder 
 
 
No flaming more than 10s 
 
 
Soldered terminations not used as protective 
mechanism 
 P 
11.2.1 Measurement 
of 
temperature 
rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
Page of 58
Display

Click on the first or last page to see other CS service manuals if exist.