Page 18 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
16 EXTERNAL 
FLEXIBLE 
CORDS 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ...........................................................: 
PVC P 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth 
 N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
2 x 0.75mm² 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)
 N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 N/A 
16.5 
Adequate strain relief on external flexible cords 
 
N/A 
 
Not possible to push cord back into equipment 
 
N/A 
 
Strain relief device unlikely to damage flexible cord   
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
 N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1 
 N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 N/A 
 
 
Page 19 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
17.1 
Torque test to table 20: 
 
- screws into metal: 5 times 
 
N/A 
 
- screws into non-metallic material: 10 times 
4.0x14.4mm,   1.2N 
4.1x22.5mm,   1.2N 
17.2 
Correct introduction into female threads in non-
metallic material 
 P 
17.3 
Cover fixing screws: captive 
 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter 
 P 
17.4 
No loosening of conductive parts carrying a current 
> 0.2 A 
 N/A 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0.2 A 
 N/A 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0.2 A with screw terminals not 
consolidated by solder 
 N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 N/A 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N/A 
17.9 
 P 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION 
 AGAINST THE EFFECTS OF IMPLOSION 
 
Picture tube separately approved to IEC 61965: 
 
N/A 
 
Picture tube separately approved to 18.1 ...............   
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
N/A 
18.2.1 
Samples subject to ageing: 6 
 
N/A 
18.2.2 
Samples subject to implosion test: 6 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
N/A 
 
 
Page 20 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg  .................:   
 
Apparatus intended to be fastened in place – 
suitable instructions 
 N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
Apparatus mass > 25 kg or height > 1 m or supplied 
with cart or stand. Topple test. 
 N/A 
19.4 
Edges or corners not hazardous 
 
19.5 
Glass surfaces with an area exceeding 0.1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
 N/A 
19.6 
Wall or ceiling mountings adequate 
 
N/A 
 
20 
RESISTANCE TO FIRE 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined in 
20.1 mounted on a board of flammability category of 
V-1 to IEC 60695-11-10 
 P 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure 
 P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
 N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
(see critical components) 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 N/A 
 
Page 21 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Apparatus with voltages > 4 kV under normal 
conditions, and distances to enclosure exceed 
those specified by Table 21, HB40 min enclosure 
 N/A 
20.2 
Fire enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 N/A 
20.2.2 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
Page of 58