JBL CS EMC - CB Certificate ▷ View online
Page 22 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES
PURPOSES
L.5.4
Battery chargers and supply apparatus marked with
model number.
model number.
N/A
L7.1.5 Lithium
batteries:
temperature rise (Normal)
N/A
L.9.1.1
Flash synchroniser teminals not hazardous live.
N/A
L.11.2.6
Lithium batteries: temperature rise (Fault).
N/A
L.14.6.6
Peak surge current and rated mains current not to
exceed mains switch current rating
exceed mains switch current rating
N/A
Page 23 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
7.1
TABLE: temperature rise measurements: Conditions
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W)………..….:…………....:
the functional switch (W)………..….:…………....:
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1 253 50 0.22 34
9
20.5
1/8 of max. non-clipping output
power
power
2 198 50 0.23 30 8.5
18
1/8 of max. non-clipping output
power
power
Loudspeaker impedance (Ω) .................................:
4Ω
—
Several
loudspeaker
systems
Marking of loudspeaker terminals
—
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 1
No ___
No ___
Toroid transformer outside.
28
—
Supply wiring insulation
23
60
PCB/heat sink
34
85
Buttons (plastic)
<10
50
Enclosure (wood)
<10
60
Enclosure (metal)
18
40
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ............................
22
—
—
Ambient temperature t2 (
o
C) ............................
23
—
—
Temperature rise dT of winding:
dT = (R
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit
maxK)
Insulation class
Transformer TT0900101020-E
Primary winding
11.20 12.462 33
85
E
Secondary winding red-red
1.269
1.428
31
85
E
Transformer
150-r4055901-e
Primary winding
10.23 -- --
85
E
Secondary winding red-red
1.351
--
--
85
E
Page 24 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
Notes: Reference Annex D
-
CLASS I: (single phase)
AC
DC
U1: Vpk
mA rms
U1: V
mA
U2: Vpk
mA rms
CLASS II: (single phase)
253V/50Hz
U1: 0.034Vpk
0.048mA rms
U1:
V
mA
253V/50Hz
U2: 0.023Vpk
0.033mA rms
mA
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (MΩ)
Min
required R
(MΩ)
Between mains poles (primary fuse disconnected)
>10
2
Between parts separated by basic or supplementary insulation
>10
2
Between parts separated by double or reinforced insulation
>10
4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120V peak
No
Between parts separated by basic or supplementary insulation
2120V peak
No
Between parts separated by double or reinforced insulation
4240V peak
No
Page 25 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0.9 or 1.1 times rated voltage .............:
220-230
—
Frequency
(Hz)……………………………………..:
50-60
—
Ambient
temperature
(
o
C) ......................................: 22-25
—
No
Component
Fault
Temp Rise/
Component
Component
Other results
(include description and test duration)
(include description and test duration)
1 Speaker
out
100%
output
T501 (windings
max)=63K
Enclosure
(metallic)=25K
PCB/heat sink =53K
max)=63K
Enclosure
(metallic)=25K
PCB/heat sink =53K
Test Voltage=253V, In= 0.68A, Pn=125W
Within 10 min temperature protection
turned on/off all the time.
turned on/off all the time.
No hazard.
2
Speaker
sc
--
Test Voltage=253V, In=0.067A, Pn=9W
Test time: 30min, Shutdown. No hazard.
3 C501
sc
--
Test
Voltage=198/253V
F501 opened immediately. No hazard.
4
Q301 c-e
sc
--
Test Voltage=253V, In=0.1A, Pn=15W
Test time: 30min.
No high temperatures ans no hazard.
5
Q302 c-e
sc
--
Test Voltage=253V, In=0.1A, Pn=15W
Test time: 30min.
No high temperatures ans no hazard.
6
Q111 c-e
sc
--
Test Voltage=253V, In=0.067A, Pn=9W
Test time: 30min, Shutdown. No hazard.
7 PW150D
V+
to AGND
sc --
Test
Voltage=198/253V
F501 opened immediately. No hazard.
8 PW150D
V-
to
AGND
sc --
Test
Voltage=198/253V
F501 opened immediately. No hazard.
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................. :
22
—
Ambient temperature t2 (
o
C) ................................. :
25
—
Click on the first or last page to see other CS service manuals if exist.