JBL CS EMC - CB Certificate ▷ View online
Page 26 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
13
TABLES: clearances and creepage distances
P
Rated supply
voltage:
voltage:
220-230 V
Pollution degree
2
Material Group
IIIa
or
IIIb
2 N force on internal parts applied:
Checked
30 N force on outside of conductive enclosure applied:
Checked
Location
Operating Voltage
Clearance (mm)
Creepage (mm)
V rms
V peak
Min
Actual
Min
Actual
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
Primary (ac) to Earth (B)
--
--
--
--
--
--
Primary (+dc) to Earth max (B)
--
--
--
--
--
--
Primary (-dc) to Earth max (B)
--
--
--
--
--
--
Across mains fuse (B) in AC inlet
230
331
2
6.6
2.3
6.6
Across primary directly connected
to the mains (B) at AC inlet
to the mains (B) at AC inlet
230
331
2
7.3
2.3
7.3
Hazardous live secondary to Earth
(B)
(B)
--
--
--
--
--
--
Optocoupler input to output (R)
--
--
--
--
--
--
Primary to Secondary (R) in
transformer.
transformer.
315
400
4.2
>10
6.7
>8.3
Primary to accessible conductive
parts (R) at mains switch.
parts (R) at mains switch.
271
383
4.0
11
5.6
11
Hazardous live secondary to non-
hazardous live secondary (R)
hazardous live secondary (R)
--
--
--
--
--
--
Hazardous live secondary to
unearthed conductive enclosure
(R)
unearthed conductive enclosure
(R)
*)
--
--
--
--
--
--
Notes:
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal
input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna
signal input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9
unless the floating secondary circuit is separated from the primary circuits by an earthed metal screen (e.g. in the
power transformer), or the floating secondary circuit is connected to earth via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits
to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as
required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
"Actual = Actual dimensions measured.
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal
input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna
signal input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9
unless the floating secondary circuit is separated from the primary circuits by an earthed metal screen (e.g. in the
power transformer), or the floating secondary circuit is connected to earth via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits
to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as
required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
"Actual = Actual dimensions measured.
*) Distances insufficient but short circuit does not cause any shock hazard.
Page 27 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14
TABLE: list of critical components and materials
P
Object/Part
No.
No.
Manufacturer
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
1
)
Transformer
T501
T501
Shanghai Transtec
TT0900101020-E
50Hz 230V
IEC 60065
Tested in the
appliance
Thermal link
Joint Force
L33
130°C 2A 250V
IEC 60691
VDE
Alt.
Transformer
T501
T501
Zhong Shan Yi Qi
Electronic Parts
Co., Ltd
150-r4055901-e
50Hz 230V
IEC 60065
Approved by
Intertek
Thermal link
Aupo Electronics Ltd.
A2-5A-F
115
°C 5A 250V
IEC 60691
VDE
Mains Fuse
F501
F501
Walter
TSD
T1.6AL 250V
IEC 60127
Appliance
inlet
inlet
Chily Precision
Industrial Co. Ltd.
3528
10A 250V
V-0
IEC 60320
VDE
Mains switch
SW501
Chily Precision
Industrial Co. Ltd.
3024 16(4)A,
8/128A
250V Class II
IEC 61058-1
IEC60065:2001 Sub-
clause 14.6.1a)
FI
X2-Capacitors
across L-N
across L-N
(EMI filter)
Europtronic
MPX
0.1µF and 0.22µF
275V
IEC 60384-14
2
nd
edition
Shrink-tub Dongguan
Quantai
Electronics
T-2 V-1
IEC
60707
--
Plastic
enclosure
enclosure
(inside
appliance)
appliance)
Chi Mei
Corporation
PA-765B V-2 IEC
60707 --
PCB
Main Circuit
Main Circuit
Jianhe FR-1 V-0
Comply
with
--
PCB
PRE-AMP
PRE-AMP
Luen Tai
FR-1
IEC 60707:1999
PCB
Secondary
Secondary
Hsiang Kuo
FR-1
The power supply cord set was not evaluated together with the apparatus. A suitable certified supply cord set
has to be added in the country were the apparatus will be sold.
has to be added in the country were the apparatus will be sold.
1
) An asterisk indicates a mark which assures the agreed level of surveillance.
2
) Description to include adjacent markings for critical fuse/s.
Page 28 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Group differences
IEC 60065:2001 + A1
CB Bulletin 112A / GRP 06 II
Contents
Add the following annexes:
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures
from headphones or earphones
from headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
N/A
4.1.1
Replace
the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
50333
.
P
5.1.i)
Add
the following note:
NOTE For RATED POWER CONSUMPTION
mesurements of TVs reference is made to EN 60107.
mesurements of TVs reference is made to EN 60107.
P
Page 29 of 45
Report No. 703637
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6.1
Replace
the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
N/A
13.3.1
Delete
note 4.
P
14
Delete
note 4 and note 5.
P
15.1.1
Delete
notes 1 and 2.
P
15.2
Delete
note 2.
P
16.1
Delete
note 1.
P
16.2
Delete
the note.
P
20
Delete
note 2.
P
Click on the first or last page to see other CS service manuals if exist.