Page 10 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² 
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 
11.2.5 
Temperature rise of windings 
 
11.2.6 Temperature 
rise 
of 
parts not subject to the limits of 
11.2.1 to 11.2.5 Table 3 e) "Other Parts" 
 P 
 
12 MECHANICAL 
STRENGTH 
12.1.1 
Bump test where mass >7 kg 
 
12.1.2 
Vibration test (portable, metal, musical amps) 
No connection of part, which 
might impair safety, can 
become loose. 
12.1.3 
Impact hammer test  
 
 
Steel ball test (for non-ventilated solid areas) 
 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg   
N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
N/A 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
Page 11 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
13.1 
Clearances in accordance with 13.3 
 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
 
13.3 
Clearances 
 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
 P 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Circuits not conductively 
connected to the mains cannot 
cause any shock hazard 
N/A 
13.3.4 
Measurement of transient voltages 
 
N/A 
13.4 
Creepage distances 
 
Creepage distances greater than table 11 minima 
 
13.5 
Printed boards 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 N/A 
13.6 Conductive 
parts 
along 
uncemented 
joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N/A 
 
 
Page 12 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14 COMPONENTS 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 Resistors 
separately 
approved 
..............................: 
Yes/No 
N/A 
14.2 
Capacitors and RC units 
 Capacitors 
separately 
approved 
 
N/A 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition ...:   
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ...:   
N/A 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  .....................: 
 N/A 
14.2.5     a)  Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better ......................................................................: 
 N/A 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ...............................................: 
 N/A 
 
Shielded by a barrier per Table 21 .........................:   
N/A 
14.3 
Inductors and windings 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ..............................: 
TRANSTEC 
TT0900101020-E 
alt. 
Zhong Shan Yi Qi 
150-r4055901-e 
 
Transformers and inductors separately approved .:  No 
N/A 
14.3.2 General 
14.3.3, 
14.3.4.1, 14.3.5.1 
 
Page 13 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14.3.3 
Constructional requirements (complete appended tables or include manufacturers 
constructional insulation descriptions) 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional requirements   
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
TT0900101020-E 
Prim. – sec.= >10mm 
150-r4055901-e: 
Prim. – sec.= >8.3mm 
 
Coil formers and partition walls = 0.4 mm 
Thin sheet 
14.3.4.2 Class 
transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Core not connected to 
accessible parts. 
N/A 
 
Coil formers and partition walls = 0.4 mm 
Thin sheet 
N/A 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved 
 N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N/A 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
 P 