DOWNLOAD JBL CS Service Manual ↓ Size: 7.26 MB | Pages: 58 in PDF or view online for FREE

Model
CS
Pages
58
Size
7.26 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cs.pdf
Date

JBL CS EMC - CB Certificate ▷ View online

 
Page 14 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to  
IEC 60127 
Mains fuse, F501 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...:  T1.6A L / 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ...............:   
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool .........: 
Mains fuse holder incorporated 
in separately approved 
appliance inlet. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N/A 
14.6 
Switches 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
V-0 compliance with annex G, G.1.1 
and 
Peak inrush rating of switch 
Measured/calculated inrush…………………………: 
 
 
 
 
 
 
 
Calculated: 30.2 A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 N/A 
 
Switch controlling = 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 
 N/A 
 
Page 15 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
action independent of speed of actuation 
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d), l) and m) not attaining 
excessive temperatures in use 
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
 N/A 
 
Socket outlet current marking correct 
 
N/A 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
14.9 
Motors 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 Dielectric 
strength 
test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
 N/A 
14.10 
Batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits 
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 Battery 
drop 
test 
 
N/A 
 
Page 16 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14.11 
Optocouplers 
 
Optocouplers comply with Cl. 8 
 
N/A 
 
 N/A 
14.12 
Surge suppression varistors 
 
Comply with IEC 61051-2 
 
N/A 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus 
 N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 N/A 
 
15 TERMINALS 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the  cross-
sectional area specified in 16.2 for external cords 
(See list of critical components) 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
 
 
No risk of insertion into audio or video-outlets 
marked with the symbol of 5.2 
 N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
 N/A 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
 N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N/A 
 
Earthing connection of parts removable by hand. 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0.1 
Ω at 25 A ...................:   N/A 
 
Page 17 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
15.3 
Terminals for external flexible cords and for permanent connection to the mains supply 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
Not soldered to conductors of a printed circuit board Appliance inlet 
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 N/A 
 
Wire secured by additional means to the conductor   
N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
 N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means 
 N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws 
 N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment 
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16   
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided 
 N/A 
15.3.8 
Terminals carrying a current more than 0.2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 N/A 
15.3.9 
Termination of non-detachable cords/wires 
terminated near to each other 
 N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
 N/A 
15.4 
Devices forming a part of the mains plug 
15.4.1 
No undue strain on mains socket-outlets 
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N/A 
15.4.3 
Device has adequate mechanical strength  
(tests a, b, c) 
 N/A 
 
Page of 58
Display

Click on the first or last page to see other CS service manuals if exist.