DOWNLOAD JBL CS Service Manual ↓ Size: 7.26 MB | Pages: 58 in PDF or view online for FREE

Model
CS
Pages
58
Size
7.26 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cs.pdf
Date

JBL CS EMC - CB Certificate ▷ View online

 
Page 3 of 45 
Report No. 703637 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Summary of testing: 
Tests performed (name of test and test clause): 
IEC 60065:2001 + Amendment 1 
Testing location: 
See page 2 
 
Summary of compliance with National Differences: 
National differences Korea 
National differences Singapore 
 
Copy of marking plate 
 
 
 
Page 4 of 45 
Report No. 703637 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
Test item particulars
................................................. :  Powered Subwoofer 
Classification of installation and use........................... :  Class II 
Supply Connection ..................................................... :  Appliance inlet 
.................................................................................... : – 
.................................................................................... : – 
Possible test case verdicts: 
 
- test case does not apply to the test object ................ : N/A (Not Applicable) 
- test object does meet the requirement ...................... : P (Pass) 
- test object does not meet the requirement................ : F (Fail) 
Testing
........................................................................ : See general product information. 
Date of receipt of test item........................................... : – 
Date (s) of performance of tests .................................. : – 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a point is used as the decimal separator. 
 
General product information: 
A new investigation has been issued due to adding of a new power transformer and updating of standard to 
IEC 60065:2001 + Amendment 1 / EN 60065:2002 + Amendment 1. 
 
The results in this Test Report are based on testing of model CS100SUB/230 with certificate No. 
SE-48831 and Test Report ref. No. 700085, according to IEC 60065:2001 / EN 60065:2002 and the 
evaluation of the power transformer 150-r4055901-e with ref. No. 703341. 
 
 
 
Page 5 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus  ................................:  Class II 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 
Ventilation instructions require the use of the test 
box 
No P 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit 
 P 
5.1  
a), b) 
Identification, maker, model ...................................: 
, CS100SUB/230 
c) 
Class II symbol if applicable 
 
d), e) 
Rated supply voltage and symbol ..........................:  AC 220-230V  
f) 
Frequency if safety dependant 
50-60Hz 
g), h), i) 
Rated current or power consumption  ....................:  250 W 
5.2 a) 
Earth terminal 
 
N/A 
b) 
Hazardous live terminals 
 
N/A 
c) 
Supply output terminals (other than mains) 
 
N/A 
5.3 
Use of triangle with exclamation mark 
 
5.4 
Instructions for use 
5.4.1  
a) 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled with 
liquid, etc. 
 P 
b) 
Hazardous live terminals, instructions for wiring 
 
N/A 
c) 
Instructions for replacing lithium battery 
 
N/A 
 
Instructions for modem if fitted 
 
N/A 
d) 
Class I earth connection warning 
 
N/A 
e) 
Instructions for multimedia system connection 
 
N/A 
f) 
Special stability warning for fixed installation 
 
N/A 
g) 
Batteries not exposed to heat/sun warning 
 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
 P 
 
Instructions for permanently connected equipment 
 
N/A 
 
Page of 58
Display