Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such component. 
N/A 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Considered. 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Operations intended to be 
performed by hand do not 
result in an increased risk of 
shock hazard. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
 
N/A 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover is removable by hand. 
Pass 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Class II apparatus. 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) 
 
N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 
Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Transformer complied with 14.3 
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such component used. 
N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such component used. 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Bridged capacitor complied with 
14.2.1 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such component used. 
N/A 
8.7 
This sub-clause is void 
 
N/A 
 
 
 
 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0,4 mm (mm)  ....................................... : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  .................... :  Heat shrinkable tubing coverd 
on power switch: min. 0.4 mm. 
The bobbin of transformer  
measured min. 0.71 mm 
Pass 
 
Page 9 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
Insulating tape in transformer. 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 dielectric 
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 dielectric 
 
N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 dielectric 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 dielectric 
Three layers of insulation tape 
provided between hazardous 
live winding and non-hazards 
live winding of transformer. 
Each two layers passes 
dielectric strength test at 
4240Vdc. 
Pass  
8.9 
Primary Wiring: Adequate insulation between 
internal hazardous live conductors and accessible 
parts 
Measured min. 0.4mm 
Pass 
 
Secondary Wiring: Adequate insulation between 
internal hazardous live parts and conductors 
connected to accessible parts 
Measured min. 0.4mm 
Pass 
8.10 
Class II Wiring: 
(1) Primary: Double insulation between conductors 
connected to the mains and accessible parts. 
(2) Secondary: Double insulation between 
conductors connected to accessible parts and the 
mains 
 
Pass 
8.11 
Detaching of wires 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
No wire could be become 
detached. 
Pass 
 
Vibration test carried out  ......................................... :  See sub-clause 12.1.2 
Pass 
8.12 
This sub-clause is void 
Complied 
Pass 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
No windows, lenses, lamp 
covers etc. 
N/A 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
No cover. 
N/A 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges (2N force) 
Complied. 
Pass 
8.16 
Only special supply equipment can be used 
No such supply equipment used. 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
No insulated winding wires are 
employed. 
N/A 
8.18 
Endurance test as required by 8.17 
Same as above. 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
 
Page 10 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
8.19.1 
Disconnect device 
AC Inlet is used as the 
disconnect device and see also 
sub-clause 5.4.2 
Pass 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
Complied. 
Pass 
8.19.2 
Mains switch ON indication 
Complied. 
Pass 
8.20 
Switch not fitted in the mains cord 
No such component used. 
N/A 
8.21 
Bridging components comply with clause 14 
Complied. 
Pass 
8.22 
Test of non-separable thin sheet material 
No such component used. 
N/A 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1    a)  Determination of Hazardous Live parts 
See below 
Pass 
b)  Touch current measured from terminal devices 
using the network in annex D  ................................. : 
The following parts were 
measured the maximum open-
circuit voltage that exceeds 35 
Vpeak or 60Vdc. 
Class II construction: 
  accessible connector and 
metal part for SB 30 CNTR 
U1:  0.49Vpeak 
U2:  0.34Vpeak 
  accessible metal part for SB 
30 SUB/230 
U1:  0.328Vpeak 
U2:  0.267Vpeak 
Pass 
c)  Discharge not exceeding 45 
μC 
Complied. 
Pass 
d)  Energy of discharge not exceeding 350 mJ 
No voltage exceeds 15kVdc. 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
Shafts of operating knobs, 
handles, levers and the like are 
not hazardous live. 
Pass 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
Test pin is not become 
hazardous live. 
Pass 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
Certified inlet used. All output 
terminals did not become 
hazardous live after test.  
Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
See above. 
Pass 
 
Page 11 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set controls used. 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s   : 
0V after 2 s for all models. 
Pass 
 
If C is not greater than 0,1 
μF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
No damage to the enclosure. 
Pass 
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
Hazardous live part is not 
accessible. 
Pass 
b) 
Test hook of fig. 4 for 10 s (20 N) 
Hazardous live part is not 
accessible. 
Pass 
c) 
Conductive enclosure: 30 mm diameter test tool for 
5 s (100 or 250 N)  ................................................... : 
250 N applied. Hazardous live 
part is not accessible. 
Pass 
9.2 
No hazard 2s after removing a cover by hand 
No covers can be removed by 
hand. 
N/A 
 
 
10 
INSULATION REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ................................................................. : 
The surge test, insulation 
resistance test and dielectric 
strength test have performed 
Pass 
10.2 
Humidity treatment 48 h or 120 h  ........................... :  At 93 % R.H., 120 hrs, 40 °C 
Pass 
10.3 
Insulation resistance and dielectric strength 
between mains terminals 
See below 
Pass 
 
Insulation resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
 
N/A 
 
Insulation resistance across REINFORCED 
insulation (Class II) 
(see appended table 10.3) 
Pass 
 
 
 
11 
FAULT CONDITIONS 
11.1 
No shock hazard under fault condition 
Accessible voltage remains non-
hazardous live.                        
See appended table 11.2. 
Pass 
11.2 
Heating under fault condition 
See below 
Pass 
 
No hazard from softening solder 
No solder point became soft. 
Pass 
 
No flaming more than 10s 
 
N/A 
 
Soldered terminations not used as protective 
mechanism 
 
Pass 
11.2.1 
Measurement of temperature rises 
Refer to appended table 11.2.  
Pass 
11.2.2 
Temperature rise of accessible parts 
Refer to appended table 11.2. 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
Refer to appended table 11.2. 
Pass 