Harman Kardon SB 30 (serv.man3) EMC - CB Certificate ▷ View online
Page 8 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such component.
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered.
Pass
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operations intended to be
performed by hand do not
result in an increased risk of
shock hazard.
performed by hand do not
result in an increased risk of
shock hazard.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover is removable by hand.
Pass
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Class II apparatus.
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Pass
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformer complied with 14.3
Pass
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such component used.
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such component used.
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
Bridged capacitor complied with
14.2.1
14.2.1
Pass
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such component used.
N/A
8.7
This sub-clause is void
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0,4 mm (mm) ....................................... :
insulation > 0,4 mm (mm) ....................................... :
N/A
Reinforced insulation > 0,4 mm (mm) .................... : Heat shrinkable tubing coverd
on power switch: min. 0.4 mm.
The bobbin of transformer
measured min. 0.71 mm
measured min. 0.71 mm
Pass
Page 9 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Insulating tape in transformer.
Pass
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which
meet 10.3 dielectric
meet 10.3 dielectric
N/A
Reinforced insulation, three layers any two which
meet 10.3 dielectric
meet 10.3 dielectric
Three layers of insulation tape
provided between hazardous
live winding and non-hazards
live winding of transformer.
Each two layers passes
dielectric strength test at
4240Vdc.
provided between hazardous
live winding and non-hazards
live winding of transformer.
Each two layers passes
dielectric strength test at
4240Vdc.
Pass
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
internal hazardous live conductors and accessible
parts
Measured min. 0.4mm
Pass
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
internal hazardous live parts and conductors
connected to accessible parts
Measured min. 0.4mm
Pass
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
conductors connected to accessible parts and the
mains
Pass
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No wire could be become
detached.
detached.
Pass
Vibration test carried out ......................................... : See sub-clause 12.1.2
Pass
8.12
This sub-clause is void
Complied
Pass
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No windows, lenses, lamp
covers etc.
covers etc.
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
No cover.
N/A
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges (2N force)
wiring due to hot parts or sharp edges (2N force)
Complied.
Pass
8.16
Only special supply equipment can be used
No such supply equipment used.
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
No insulated winding wires are
employed.
employed.
N/A
8.18
Endurance test as required by 8.17
Same as above.
N/A
8.19
Disconnection from the mains
Pass
Page 10 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
8.19.1
Disconnect device
AC Inlet is used as the
disconnect device and see also
sub-clause 5.4.2
disconnect device and see also
sub-clause 5.4.2
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
Complied.
Pass
8.19.2
Mains switch ON indication
Complied.
Pass
8.20
Switch not fitted in the mains cord
No such component used.
N/A
8.21
Bridging components comply with clause 14
Complied.
Pass
8.22
Test of non-separable thin sheet material
No such component used.
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1 a) Determination of Hazardous Live parts
See below
Pass
b) Touch current measured from terminal devices
using the network in annex D ................................. :
The following parts were
measured the maximum open-
circuit voltage that exceeds 35
Vpeak or 60Vdc.
measured the maximum open-
circuit voltage that exceeds 35
Vpeak or 60Vdc.
Class II construction:
accessible connector and
metal part for SB 30 CNTR
U1: 0.49Vpeak
U2: 0.34Vpeak
accessible metal part for SB
30 SUB/230
U1: 0.328Vpeak
U2: 0.267Vpeak
Pass
c) Discharge not exceeding 45
μC
Complied.
Pass
d) Energy of discharge not exceeding 350 mJ
No voltage exceeds 15kVdc.
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
Shafts of operating knobs,
handles, levers and the like are
not hazardous live.
handles, levers and the like are
not hazardous live.
Pass
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
Test pin is not become
hazardous live.
hazardous live.
Pass
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
Certified inlet used. All output
terminals did not become
hazardous live after test.
terminals did not become
hazardous live after test.
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
See above.
Pass
Page 11 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls used.
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
0V after 2 s for all models.
Pass
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Enclosure sufficiently resistant to external force
No damage to the enclosure.
Pass
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
Hazardous live part is not
accessible.
accessible.
Pass
b)
Test hook of fig. 4 for 10 s (20 N)
Hazardous live part is not
accessible.
accessible.
Pass
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ................................................... :
5 s (100 or 250 N) ................................................... :
250 N applied. Hazardous live
part is not accessible.
part is not accessible.
Pass
9.2
No hazard 2s after removing a cover by hand
No covers can be removed by
hand.
hand.
N/A
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ................................................................. :
The surge test, insulation
resistance test and dielectric
strength test have performed
resistance test and dielectric
strength test have performed
Pass
10.2
Humidity treatment 48 h or 120 h ........................... : At 93 % R.H., 120 hrs, 40 °C
Pass
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
See below
Pass
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance across REINFORCED
insulation (Class II)
insulation (Class II)
(see appended table 10.3)
Pass
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
Accessible voltage remains non-
hazardous live.
See appended table 11.2.
hazardous live.
See appended table 11.2.
Pass
11.2
Heating under fault condition
See below
Pass
No hazard from softening solder
No solder point became soft.
Pass
No flaming more than 10s
N/A
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
Refer to appended table 11.2.
Pass
11.2.2
Temperature rise of accessible parts
Refer to appended table 11.2.
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
Refer to appended table 11.2.
Pass