Page 35 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
12 
U5 Pin1 
Open 
0.05 
Unit shutdown immediately, NCD, No 
hazard. 
13 
T2 Pin3 to Pin5 
Short 
0.12 
Unit shut down immediately, except for 
stand by funtion, NCD, No hazard. 
14 
T2 Pin9 to Pin11  Short 
0.12 
Unit shut down immediately, except for 
stand by funtion, NCD, No hazard. 
15 
T2 Pin10 to Pin11  Short 
0.12 
Unit shut down immediately, except for 
stand by funtion, NCD, No hazard. 
16 
U4 Pin3 to Pin4 
Short 
0.16 
Unit operation normally. NCD, No hazard.  
17 
U4 Pin1 to Pin2 
Short 
0.16 
Unit operation normally. NCD, No hazard.  
18 
U4 Pin4 
Open 
0.05 
Unit shutdown immediately, NCD, No 
hazard. 
19 
U4 Pin1 
Open 
0.05 
Unit shutdown immediately, NCD, No 
hazard. 
20 
Q3 Pin G to Pin S  Short 
0.12 
Unit shut down immediately, except for 
stand by 
NCD, No hazard. 
21 
Q3 Pin D to Pin S  Short 
0.05 
Unit shutdown immediately, NCD, No 
hazard. 
22 
Q3 Pin D to Pin G  Short 
Fuse open immediately, no hazard. 
23 
C38 
Short 
Fuse open immediately, no hazard. 
24 
BR1 Pin1 to Pin2  Short 
Fuse open immediately, no hazard. 
25 
U1 Pin4 to Pin5 
Short 
Fuse open immediately, no hazard. 
26 
T1 Pin3 after D1 to 
Pin2 
Overload 
0.16 to 0.181 to 
0.05 
Unit shutdown when load to 1.5A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
27 
T1 Pin1 after D3 to 
Pin2 
Overload 
0.16 to 0.186 to 
0.05 
Unit shutdown when load to 2.2A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
28 
T2 Pin9 after D6 to 
Pin11 
Overload 
0.16 to 0.177 to 
0.05 
Unit shutdown when load to 10A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
29 
Voltage Switch at 
115V 
Voltage 
mismatch 
Mains supply voltage 264Vac, fuse open 
immediately, no hazard. 
30 
Voltage Switch at 
230V 
Voltage 
mismatch 
0.05 
Mains supply voltage 132Vac, NCD, no 
hazard. 
FI: Final Input current; IP: Internal Protection occurred; NCD: No Components Damaged 
Temperature Rise dT of Part 
dT (K) 
Limit dT (K) 
Test Condition No.  
14 
17 
26 
27 
28 
-- 
For power board 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
AC Inlet 
7.9  
6.1  
9.4  
8.8  
8.3  
17.5   150 
CN1 body 
12.7   17.7   12.1   16.4   16.9   62.7   150 
 
Page 36 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
PCB near TH1 and ZNR1 
15.4   21.8   15.1   16.7   17.1   80.0   150 
CX1 body 
15.2   22.6   15.0   15.7   16.2   67.8   150 
LF1 coil 
14.0   21.5   14.1   13.6   14.0   56.9   150 
CX2 body 
14.3   22.1   14.4   13.5   13.9   59.5   150 
LF2 coil 
15.7   24.5   16.2   14.5   15.0   77.5   150 
PCB near BR1 
17.1   25.5   18.0   16.7   17.1   86.4   150 
C4 body 
20.2   31.9   19.1   19.0   19.6   70.4   150 
PCB near Q3 
37.5   55.0   23.3   29.8   30.9   84.9   150 
T2 core 
31.0   53.2   56.7   35.9   36.6   117.4   140 (150-10) 
T2 coil 
31.8   45.5   57.5   37.7   38.6   114.6   140 (150-10) 
U4 body 
48.2   36.0   54.3   52.7   53.6   64.0   150 
CY body on AC Inlet Line 
20.9   33.5   31.0   26.7   27.0   73.9   150 
T1 coil 
20.3   23.3   26.9   69.2   64.2   57.2   140 (150-10) 
T1 core 
21.1   25.1   27.9   57.3   59.4   54.1   140 (150-10) 
CY1 body 
21.5   25.8   27.9   40.4   45.0   48.5   150 
CY2 body 
22.2   26.6   28.1   32.6   39.6   44.2   150 
PCB near D8 
19.5   31.8   31.0   31.9   32.5   114.9   150 
For main board 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
PCB near U202 
26.4  
6.0  
31.2   28.2   29.0   26.4   150 
PCB near U503 
28.3  
5.9  
32.7   28.0   29.0   26.1   150 
L509 coil 
29.5  
5.8  
34.2   31.0   32.0   29.0   150 
L514 coil 
35.4  
6.7  
40.8   36.9   37.9   34.6   150 
For other part 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
Metal enclosure outside near T2 
9.7  
12.9   12.1   10.6   10.7   32.5   65 
Metal enclosure outside near heat sink 
19.9  
4.6  
22.9   18.8   20.6   18.0   65 
Plastic enclosure inside near T2 
15.7   23.1   23.2   20.7   21.6   63.3   65 
Plastic enclosure outside top near T2 
8.4  
10.7   13.1  
7.8  
9.4  
33.5   65 
Primary wire  
12.6   18.2   12.1   10.3   10.4   34.2   150 
Ambient 
21.7 
21.9 
23.0 
29.0 
29.3 
30.8 
o
Test with model: SB 30 SUB 
No 
Component 
Fault 
Fuse current 
Other results 
(include description and test duration) 
BR1 Pin2 to Pin1 
Short 
Fuse open immediately, no hazard. 
C1 
Short 
Fuse open immediately, no hazard. 
 
Page 37 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
DT1 Pin9 to Pin8 
 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard. Fuse current: 0.06 A 
DT1 Pin3 to Pin1 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard. Fuse current: 0.06 A 
Q6 Pin G to Pin D  Short 
Fuse open immediately, no hazard. 
Q6 Pin D to Pin S 
Short 
Fuse open immediately, no hazard. 
Q6 Pin G to Pin S  Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
Q7 Pin G to Pin D  Short 
Fuse open immediately, no hazard. 
Q7 Pin D to Pin S 
Short 
Fuse open immediately, no hazard. 
10 
Q7 Pin G to Pin S  Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
11 
T2 Pin9 to Pin10 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard. 
12 
T2 Pin7 to Pin10 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
13 
U1 Pin5 to Pin2 
Short 
Fuse open immediately, no hazard. 
14 
T1 Pin5 to Pin4 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
15 
T1 Pin3 to Pin4 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
16 
T1 Pin2 to Pin1 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
17 
T1 Pin8 to Pin9, 
SC 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
18 
U2 Pin1 to Pin2 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
19 
U2 Pin3 to Pin4 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard.  
20 
U2 Pin 1 
Open 
0.264 
Unit operated normally, NCD, No hazard. 
21 
U2 Pin 3 
Open 
0.264 
Unit operated normally 
NCD, No hazard. 
22 
CN4 Pin1 to Pin2 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard. Fuse current: 0.06 A 
23 
CN2 Pin1 to Pin2 
Short 
0.06 
Unit shutdown immediately, NCD, no 
hazard. Fuse current: 0.06 A 
24 
CN2 Pin2 to Pin3 
Short 
Fuse open immediately, no hazard. 
25 
DT1 Pin9 to SGND   Overload 
0.264 to 0.32 to 
0.06 
Unit shutdown when load to 0.12A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
26 
T2  Pin  10  to  T2 
Pin9 after D8  
Overload 
0.264 to 1.56 to 
0.06 
Unit shutdown when load to 1.5A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
 
Page 38 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
27 
T1 Pin4 to T1 Pin5 
afterD1  
Overload 
0.264 to 0.48 to 
0.06 
Unit shutdown when load to 1.2A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
28 
T1 Pin4 to T1 Pin3 
after D9  
Overload 
0.264 to 0.47 to 
0.06 
Unit shutdown when load to 1.4A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
29 
T1 Pin4 to T1 Pin2 
after D4  
Overload 
0.264 to 0.41 to 
0.06 
Unit shutdown when load to 0.6A. 
The maximum temperature of Each 
monitored points were listed in the following 
table.  NCD ,No hazard 
FI: Final Input current; IP: Internal Protection occurred; NCD: No Components Damaged 
Temperature Rise dT of Part 
dT (K) 
Limit dT (K) 
Test Condition No.  
19 
20 
25 
26 
27 
28 
29 
-- 
For power board 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
Primary wire  
15.5   15.4   16.8   27.9   17.0   15.3  17.0   150 
CN1 body 
17.1   16.8   18.4   31.4   18.7   16.9  18.7   150 
PCB near ZNR1 and TH1 
17.8   17.8   19.6   42.9   21.1   17.8  21.5   150 
CX1 body 
15.7   15.6   17.1   37.9   17.6   15.5  17.9   150 
LF1 coil 
16.5   16.4   18.1   53.6   19.1   16.3  19.3   150 
CX2 body 
15.5   15.4   16.9   41.4   17.5   15.3  17.6   150 
LF2 body 
15.5   15.5   17.0   44.7   17.8   15.3  17.9   150 
CY1 body 
14.3   14.2   15.6   27.4   16.0   14.1  15.7   150 
PCB  near BR1 
16.3   16.3   17.9   33.3   18.5   16.2  18.3   150 
C1 body 
22.3   22.2   24.1   48.7   24.7   22.2  24.5   150 
PCB near Q1 
39.8   39.4   41.5   51.7   42.2   39.6  42.1   150 
T2 coil 
46.3   46.1   48.6   76.2   48.8   46.5  48.4   140 (150-10) 
T2 core 
52.1   52.0   54.7   83.2   54.9   52.8  54.7   140 (150-10) 
CT1 coil 
48.5   48.2   51.6   72.1   50.9   48.4  50.3   140 (150-10) 
CT1 core 
44.1   43.8   46.8   63.5   46.5   43.9  45.6   140 (150-10) 
DT1 coil 
35.8   35.6   39.0   50.3   38.6   35.6  37.5   140 (150-10) 
DT1 core 
32.7   32.4   36.2   46.7   35.7   32.5  34.4   140 (150-10) 
T1 coil 
45.5   40.4   47.9   50.9   77.9   45.3  71.9   140 (150-10) 
T1 core 
43.7   40.1   47.6   52.2   69.0   43.5  64.8   140 (150-10) 
CY4 body 
36.0   35.3   40.8   48.5   41.7   35.8  40.7   150 
U2 body 
37.5   35.9   41.7   47.4   48.1   37.3  47.4   150 
PCB near D8 
23.1   22.9   25.2   46.6   25.5   22.9  24.7   150 
For main board 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
-- 
Page of 76