Harman Kardon SB 30 (serv.man3) EMC - CB Certificate ▷ View online
Page 35 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
12
U5 Pin1
Open
0.05
Unit shutdown immediately, NCD, No
hazard.
hazard.
13
T2 Pin3 to Pin5
Short
0.12
Unit shut down immediately, except for
stand by funtion, NCD, No hazard.
stand by funtion, NCD, No hazard.
14
T2 Pin9 to Pin11 Short
0.12
Unit shut down immediately, except for
stand by funtion, NCD, No hazard.
stand by funtion, NCD, No hazard.
15
T2 Pin10 to Pin11 Short
0.12
Unit shut down immediately, except for
stand by funtion, NCD, No hazard.
stand by funtion, NCD, No hazard.
16
U4 Pin3 to Pin4
Short
0.16
Unit operation normally. NCD, No hazard.
17
U4 Pin1 to Pin2
Short
0.16
Unit operation normally. NCD, No hazard.
18
U4 Pin4
Open
0.05
Unit shutdown immediately, NCD, No
hazard.
hazard.
19
U4 Pin1
Open
0.05
Unit shutdown immediately, NCD, No
hazard.
hazard.
20
Q3 Pin G to Pin S Short
0.12
Unit shut down immediately, except for
stand by
NCD, No hazard.
stand by
NCD, No hazard.
21
Q3 Pin D to Pin S Short
0.05
Unit shutdown immediately, NCD, No
hazard.
hazard.
22
Q3 Pin D to Pin G Short
0
Fuse open immediately, no hazard.
23
C38
Short
0
Fuse open immediately, no hazard.
24
BR1 Pin1 to Pin2 Short
0
Fuse open immediately, no hazard.
25
U1 Pin4 to Pin5
Short
0
Fuse open immediately, no hazard.
26
T1 Pin3 after D1 to
Pin2
Overload
0.16 to 0.181 to
0.05
Unit shutdown when load to 1.5A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
27
T1 Pin1 after D3 to
Pin2
Overload
0.16 to 0.186 to
0.05
Unit shutdown when load to 2.2A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
28
T2 Pin9 after D6 to
Pin11
Overload
0.16 to 0.177 to
0.05
Unit shutdown when load to 10A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
29
Voltage Switch at
115V
Voltage
mismatch
mismatch
0
Mains supply voltage 264Vac, fuse open
immediately, no hazard.
immediately, no hazard.
30
Voltage Switch at
230V
Voltage
mismatch
mismatch
0.05
Mains supply voltage 132Vac, NCD, no
hazard.
hazard.
FI: Final Input current; IP: Internal Protection occurred; NCD: No Components Damaged
Temperature Rise dT of Part
dT (K)
Limit dT (K)
Test Condition No.
1
14
17
26
27
28
--
For power board
--
--
--
--
--
--
--
AC Inlet
7.9
6.1
9.4
8.8
8.3
17.5 150
CN1 body
12.7 17.7 12.1 16.4 16.9 62.7 150
Page 36 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
PCB near TH1 and ZNR1
15.4 21.8 15.1 16.7 17.1 80.0 150
CX1 body
15.2 22.6 15.0 15.7 16.2 67.8 150
LF1 coil
14.0 21.5 14.1 13.6 14.0 56.9 150
CX2 body
14.3 22.1 14.4 13.5 13.9 59.5 150
LF2 coil
15.7 24.5 16.2 14.5 15.0 77.5 150
PCB near BR1
17.1 25.5 18.0 16.7 17.1 86.4 150
C4 body
20.2 31.9 19.1 19.0 19.6 70.4 150
PCB near Q3
37.5 55.0 23.3 29.8 30.9 84.9 150
T2 core
31.0 53.2 56.7 35.9 36.6 117.4 140 (150-10)
T2 coil
31.8 45.5 57.5 37.7 38.6 114.6 140 (150-10)
U4 body
48.2 36.0 54.3 52.7 53.6 64.0 150
CY body on AC Inlet Line
20.9 33.5 31.0 26.7 27.0 73.9 150
T1 coil
20.3 23.3 26.9 69.2 64.2 57.2 140 (150-10)
T1 core
21.1 25.1 27.9 57.3 59.4 54.1 140 (150-10)
CY1 body
21.5 25.8 27.9 40.4 45.0 48.5 150
CY2 body
22.2 26.6 28.1 32.6 39.6 44.2 150
PCB near D8
19.5 31.8 31.0 31.9 32.5 114.9 150
For main board
--
--
--
--
--
--
--
PCB near U202
26.4
6.0
31.2 28.2 29.0 26.4 150
PCB near U503
28.3
5.9
32.7 28.0 29.0 26.1 150
L509 coil
29.5
5.8
34.2 31.0 32.0 29.0 150
L514 coil
35.4
6.7
40.8 36.9 37.9 34.6 150
For other part
--
--
--
--
--
--
--
Metal enclosure outside near T2
9.7
12.9 12.1 10.6 10.7 32.5 65
Metal enclosure outside near heat sink
19.9
4.6
22.9 18.8 20.6 18.0 65
Plastic enclosure inside near T2
15.7 23.1 23.2 20.7 21.6 63.3 65
Plastic enclosure outside top near T2
8.4
10.7 13.1
7.8
9.4
33.5 65
Primary wire
12.6 18.2 12.1 10.3 10.4 34.2 150
Ambient
21.7
21.9
23.0
29.0
29.3
30.8
o
C
Test with model: SB 30 SUB
No
Component
Fault
Fuse current
Other results
(include description and test duration)
(include description and test duration)
1
BR1 Pin2 to Pin1
Short
0
Fuse open immediately, no hazard.
2
C1
Short
0
Fuse open immediately, no hazard.
Page 37 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
3
DT1 Pin9 to Pin8
Short
0.06
Unit shutdown immediately, NCD, no
hazard. Fuse current: 0.06 A
hazard. Fuse current: 0.06 A
4
DT1 Pin3 to Pin1
Short
0.06
Unit shutdown immediately, NCD, no
hazard. Fuse current: 0.06 A
hazard. Fuse current: 0.06 A
5
Q6 Pin G to Pin D Short
0
Fuse open immediately, no hazard.
6
Q6 Pin D to Pin S
Short
0
Fuse open immediately, no hazard.
7
Q6 Pin G to Pin S Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
8
Q7 Pin G to Pin D Short
0
Fuse open immediately, no hazard.
9
Q7 Pin D to Pin S
Short
0
Fuse open immediately, no hazard.
10
Q7 Pin G to Pin S Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
11
T2 Pin9 to Pin10
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
12
T2 Pin7 to Pin10
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
13
U1 Pin5 to Pin2
Short
0
Fuse open immediately, no hazard.
14
T1 Pin5 to Pin4
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
15
T1 Pin3 to Pin4
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
16
T1 Pin2 to Pin1
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
17
T1 Pin8 to Pin9,
SC
SC
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
18
U2 Pin1 to Pin2
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
19
U2 Pin3 to Pin4
Short
0.06
Unit shutdown immediately, NCD, no
hazard.
hazard.
20
U2 Pin 1
Open
0.264
Unit operated normally, NCD, No hazard.
21
U2 Pin 3
Open
0.264
Unit operated normally
NCD, No hazard.
NCD, No hazard.
22
CN4 Pin1 to Pin2
Short
0.06
Unit shutdown immediately, NCD, no
hazard. Fuse current: 0.06 A
hazard. Fuse current: 0.06 A
23
CN2 Pin1 to Pin2
Short
0.06
Unit shutdown immediately, NCD, no
hazard. Fuse current: 0.06 A
hazard. Fuse current: 0.06 A
24
CN2 Pin2 to Pin3
Short
0
Fuse open immediately, no hazard.
25
DT1 Pin9 to SGND Overload
0.264 to 0.32 to
0.06
Unit shutdown when load to 0.12A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
26
T2 Pin 10 to T2
Pin9 after D8
Pin9 after D8
Overload
0.264 to 1.56 to
0.06
Unit shutdown when load to 1.5A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
Page 38 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
27
T1 Pin4 to T1 Pin5
afterD1
afterD1
Overload
0.264 to 0.48 to
0.06
Unit shutdown when load to 1.2A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
28
T1 Pin4 to T1 Pin3
after D9
after D9
Overload
0.264 to 0.47 to
0.06
Unit shutdown when load to 1.4A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
29
T1 Pin4 to T1 Pin2
after D4
after D4
Overload
0.264 to 0.41 to
0.06
Unit shutdown when load to 0.6A.
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
The maximum temperature of Each
monitored points were listed in the following
table. NCD ,No hazard
FI: Final Input current; IP: Internal Protection occurred; NCD: No Components Damaged
Temperature Rise dT of Part
dT (K)
Limit dT (K)
Test Condition No.
19
20
25
26
27
28
29
--
For power board
--
--
--
--
--
--
--
--
Primary wire
15.5 15.4 16.8 27.9 17.0 15.3 17.0 150
CN1 body
17.1 16.8 18.4 31.4 18.7 16.9 18.7 150
PCB near ZNR1 and TH1
17.8 17.8 19.6 42.9 21.1 17.8 21.5 150
CX1 body
15.7 15.6 17.1 37.9 17.6 15.5 17.9 150
LF1 coil
16.5 16.4 18.1 53.6 19.1 16.3 19.3 150
CX2 body
15.5 15.4 16.9 41.4 17.5 15.3 17.6 150
LF2 body
15.5 15.5 17.0 44.7 17.8 15.3 17.9 150
CY1 body
14.3 14.2 15.6 27.4 16.0 14.1 15.7 150
PCB near BR1
16.3 16.3 17.9 33.3 18.5 16.2 18.3 150
C1 body
22.3 22.2 24.1 48.7 24.7 22.2 24.5 150
PCB near Q1
39.8 39.4 41.5 51.7 42.2 39.6 42.1 150
T2 coil
46.3 46.1 48.6 76.2 48.8 46.5 48.4 140 (150-10)
T2 core
52.1 52.0 54.7 83.2 54.9 52.8 54.7 140 (150-10)
CT1 coil
48.5 48.2 51.6 72.1 50.9 48.4 50.3 140 (150-10)
CT1 core
44.1 43.8 46.8 63.5 46.5 43.9 45.6 140 (150-10)
DT1 coil
35.8 35.6 39.0 50.3 38.6 35.6 37.5 140 (150-10)
DT1 core
32.7 32.4 36.2 46.7 35.7 32.5 34.4 140 (150-10)
T1 coil
45.5 40.4 47.9 50.9 77.9 45.3 71.9 140 (150-10)
T1 core
43.7 40.1 47.6 52.2 69.0 43.5 64.8 140 (150-10)
CY4 body
36.0 35.3 40.8 48.5 41.7 35.8 40.7 150
U2 body
37.5 35.9 41.7 47.4 48.1 37.3 47.4 150
PCB near D8
23.1 22.9 25.2 46.6 25.5 22.9 24.7 150
For main board
--
--
--
--
--
--
--
--