DOWNLOAD Harman Kardon SB 30 (serv.man3) Service Manual ↓ Size: 3.41 MB | Pages: 76 in PDF or view online for FREE

Model
SB 30 (serv.man3)
Pages
76
Size
3.41 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-30-sm3.pdf
Date

Harman Kardon SB 30 (serv.man3) EMC - CB Certificate ▷ View online

 
Page 16 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :  Fuse:  
For model SB 30 CNTR (Fuse): 
T 4.0 AL, 250 V for 100~120 V~; 
T 2,0 AL, 250 V for 220-240 V~ 
For model SB 30 SUB (F1):  
T 4.0AL, 250V 
For model SB 30 SUB/230 (F1): 
T 2.5 AL, 250 V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel  ................ :  Not used. 
N/A 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
The fuse-link (FUSE) not 
possible replacing by hand. 
Thus, no hazardous live parts 
are accessible during 
replacement of fuse-link. 
Pass 
14.5.3 
PTC thermistors comply with IEC 60730-1 
No such components. 
N/A 
 
PTC devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
No such components. 
N/A 
14.6 
Switches 
See below. 
Pass 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
V-0 compliance with annex G, G.1.1 
and 
Peak inrush rating of switch 
Measured/calculated inrush…………………………: 
Certified switch provided, 
comply with the requirements 
and characteristics, refer to 
appended table 14. 
Pass 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 
14.6.4 and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 
N/A 
 
Switch controlling = 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
action independent of speed of actuation 
 
N/A 
 
Page 17 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d), l) and m) not 
attaining excessive temperatures in use 
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 
N/A 
 
Socket outlet current marking correct 
 
N/A 
14.7 
Safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
No safety interlocks. 
N/A 
14.8 
Voltage setting devices and the like 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
 
N/A 
14.9 
Motors 
N/A 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
 
14.9.3 
Protection against moving parts 
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 
N/A 
14.10 
Batteries 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 
N/A 
14.10.4 
Battery mould stress relief 
 
N/A 
14.10.5 
Battery drop test 
 
N/A 
14.11 
Optocouplers 
Pass 
 
Optocouplers comply with Cl. 8 
Approved optocouplers used. 
Pass 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
See appended table 14 
Pass 
14.12 
Surge suppression varistors 
Pass 
 
Comply with IEC 61051-2 
See appended table 14 
Pass 
 
Page 18 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
N/A 
 
 
15 
TERMINALS 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Approved appliance inlet and 
mains plug used. 
Pass 
 
Overloading of plugs or appliance inlets prevented 
if the apparatus has mains socket outlets 
 
N/A 
 
Overloading  of internal wiring prevented if the 
apparatus has mains socket outlets 
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
Pass 
 
No risk of insertion in mains socket-outlets 
No such socket-outlets. 
Pass 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II apparatus. 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
N/A 
 
Earthing connection of parts removable by hand. 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  ................... :   
N/A 
15.3 
Terminals for external flexible cords and for permanent connection to the mains 
supply 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
Not permanent connected 
equipment. 
N/A 
15.3.2 
Reliable connection of non-detachable cords: 
For models SB 30 SUB and SB 
30/230 used 
 
Not soldered to conductors of a printed circuit 
board 
 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 
 
Page 19 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Wire secured by additional means to the conductor  Primary connector used 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
No screws 
N/A 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 
N/A 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
 
P 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16  No screws 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 
P 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
 
P 
 
Terminals located and shielded: test with 8 mm 
strand 
 
P 
15.4 
Devices forming a part of the mains plug 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
Not direct plug-in equipment. 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 
N/A 
 
 
16 
EXTERNAL FLEXIBLE CORDS 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ : 
Complied with IEC 60227. 
Pass 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Class II apparatus. 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
NISPT-2, 2x0.75mm
2
 
Pass 
Page of 76
Display