Harman Kardon SB 30 (serv.man3) EMC - CB Certificate ▷ View online
Page 24 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
L7.1.5
Lithium batteries: temperature rise (Normal)
N/A
L.9.1.1
Flash synchroniser teminals not hazardous live.
N/A
L.11.2.6
Lithium batteries: temperature rise (Fault).
N/A
L.14.6.6
Peak surge current and rated mains current not to
exceed mains switch current rating
exceed mains switch current rating
N/A
Page 25 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
7.1
TABLE: temperature rise measurements: Conditions
Pass
Power consumption in the OFF/Stand-
by………….: -
-
Position of the functional switch (W) ...................... : -
—
Page 26 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Temperature Rise dT of Part
dT (K)
Limit dT (K)
Test Condition No.
2
10
11
15
--
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
Test with model SB 30 CNTR
1/8 non-clipped output
1
90Vac
50Hz
0.26
12.56
5.5
3.78
2
90Vac
60Hz
0.26
12.56
5.5
3.78
3
100Vac
50Hz
0.24
12.72
5.5
3.78
4
100Vac
60Hz
0.24
12.72
5.5
3.78
5
120Vac
50Hz
0.25
14.40
5.5
3.78
6
120Vac
60Hz
0.25
14.40
5.5
3.78
7
127Vac
50Hz
0.25
15.2
5.5
3.78
8
127Vac
60Hz
0.25
15.2
5.5
3.78
9
132Vac
50Hz
0.26
15.44
5.5
3.78
10
132Vac
60Hz
0.26
15.44
5.5
3.78
11
198Vac
50Hz
0.16
16.19
5.5
3.78
12
220Vac
50Hz
0.16
12.71
5.5
3.78
13
240Vac
50Hz
0.15
13.07
5.5
3.78
14
254Vac
50Hz
0.16
14.57
5.5
3.78
15
264Vac
50Hz
0.16
15.61
5.5
3.78
Test with model SB 30 SUB
1/8 non-clipped output
16
90Vac
50Hz
0.33
16.2
6.7
11.22
17
90Vac
60Hz
0.33
16.3
6.7
11.22
18
100Vac
50Hz
0.30
16.3
6.7
11.22
19
100Vac
60Hz
0.30
16.4
6.7
11.22
20
120Vac
50Hz
0.283
16.1
6.7
11.22
21
120Vac
60Hz
0.283
16.1
6.7
11.22
122
127Vac
50Hz
0.270
16.0
6.7
11.22
22
127Vac
60Hz
0.270
16.0
6.7
11.22
23
132Vac
50Hz
0.264
16.0
6.7
11.22
24
132Vac
60Hz
0.264
16.1
6.7
11.22
Test with model SB 30 SUB/230
1/8 non-clipped output
25
198Vac
50Hz
0.181
14.97
6.7
11.22
26
198Vac
60Hz
0.182
14.99
6.7
11.22
27
220Vac
50Hz
0.169
14.89
6.7
11.22
28
220Vac
60Hz
0.169
14.86
6.7
11.22
29
240Vac
50Hz
0.158
14.69
6.7
11.22
30
240Vac
60Hz
0.160
14.73
6.7
11.22
31
254Vac
50Hz
0.153
14.73
6.7
11.22
32
254Vac
60Hz
0.155
14.68
6.7
11.22
33
264Vac
50Hz
0.149
14.67
6.7
11.22
34
264Vac
60Hz
0.152
14.69
6.7
11.22
Loudspeaker impedance (Ω) .................................. : 4 Ω
—
Several loudspeaker systems
-
N/A
Marking of loudspeaker terminals
-
N/A
Page 27 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
For power board
--
--
--
--
--
AC Inlet
3.5
5.8
4.3
4.9
35 (70-35)
CN1 body
8.3
14.6
8.3
12.8
50 (85-35)
PCB near TH1 and ZNR1
11.8
17.1
9.7
13.4
70 (105-35)
CX1 body
10.1
15.4
9.1
12.8
50 (85-35)
LF1 coil
7.7
12.4
7.6
10.7
70 (105-35)
CX2 body
7.3
12.0
7.5
10.5
50 (85-35)
LF2 coil
8.1
13.1
8.1
11.3
70 (105-35)
PCB near BR1
9.0
14.1
9.3
12.5
70 (105-35)
C4 body
9.4
16.7
9.9
15.3
70 (105-35)
PCB near Q3
13.9
27.2
14.6
26.0
70 (105-35)
T2 core
31.1
32.8
32.7
32.1
75 (85-10)
T2 coil
34.1
34.4
35.7
33.7
75 (85-10)
U4 body
15.0
53.2
16.2
52.8
65 (100-35)
CY body on AC Inlet Line
14.9
23.8
16.0
22.8
50 (85-35)
T1 coil
11.4
17.5
13.4
16.6
75 (85-10)
T1 core
10.9
16.8
12.7
15.8
75 (85-10)
CY1 body
10.1
15.6
11.8
14.6
50 (85-35)
CY2 body
9.6
14.8
11.2
13.8
50 (85-35)
PCB near D8
15.7
20.5
17.1
19.6
70 (105-35)
For main board
--
--
--
--
--
PCB near U202
21.2
27.9
22.3
26.9
70 (105-35)
PCB near U503
19.9
28.2
21.0
27.4
70 (105-35)
L509 coil
22.2
31.6
23.4
30.9
70 (105-35)
L514 coil
27.3
38.6
28.5
37.7
70 (105-35)
For other part
--
--
--
--
--
Metal enclosure outside near T2
4.0
7.3
4.6
6.1
40
Metal enclosure outside near heat sink
11.8
16.7
12.7
16.3
40
Plastic enclosure inside near T2
11.8
16.0
12.9
15.0
60
Plastic enclosure outside top near T2
5.5
7.3
6.4
6.4
60
Primary wire
3.6
6.2
4.3
5.1
45 (80-35)
Ambient
30.1
o
C
29.2
o
C
27.9
o
C
29.5
o
C --
Test Condition No.
17
24
26
34
--
For power board
--
--
--
--
--
Primary wire
16.1
17.2
13.9
14.6
45 (80-35)