Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
Class II apparatus.
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
Pass
11.2.5
Temperature rise of windings
(see appended table 11.2)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts"
(see appended table 11.2)
Pass
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
Approx.8.7 kg, The apparatus is
still complying with relevant
requirements of this standard for
models SB 30 SUB and SB 30
SUB/230.
still complying with relevant
requirements of this standard for
models SB 30 SUB and SB 30
SUB/230.
Pass
12.1.2
Vibration test (portable, metal, musical amps)
The apparatus is still complying
with relevant requirements of this
standard.
with relevant requirements of this
standard.
Pass
12.1.3
Impact hammer test
No damage to the apparatus
after the impact test.
after the impact test.
Pass
Steel ball test (for non-ventilated solid areas)
Pass
12.1.4
Drop test for portable apparatus where mass = 7
kg
kg
Complied with SB 30 CNTR.
Pass
12.1.5
Thermoplastic enclosures stress relief test
91
o
C
Pass
12.2
Fixing of knobs, push buttons, keys and levers
No hazards.
Pass
12.3
Remote controls with hazardous live parts
No remote control used.
N/A
12.4
Drawers (pull test 50 N, 10 s)
No drawer is provided.
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna coaxial socket is
provided.
provided.
N/A
12.6
Telescoping or rod antennas construction
No such device.
N/A
12.6.1
Telescoping or rod antennas securement
No such device.
N/A
Page 13 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pollution degree: 2
Pass
Creepage distances in accordance with 13.4
See 13.4.
Pass
13.2
Determination of operating voltage
Pass
13.3
Clearances
See below.
Pass
13.3.1
General
Pass
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
(see appended table 13)
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
(see appended table 13)
Pass
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
(see appended table 13)
Pass
Creepage distances greater than table 11 minima
Considered.
Pass
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14
COMPONENTS
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such component used.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Page 14 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Resistors separately approved ............................... :
N/A
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... : Capacitor is min. Y1 type, see list
of critical components.
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ... : Capacitor is min. X2 type, see list
of critical components.
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
N/A
14.2.5 a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
N/A
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
N/A
Shielded by a barrier per Table 21 or metal ............ :
N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Tested with appliance.
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
See appended table 14.3.3
Pass
Transformers and inductors separately approved . :
N/A
14.3.2
General
See 14.3.3, 14.3.4 and 14.3.5.
Pass
Insulation material complies with clause 20.1.4
Pass
14.3.3
Constructional requirements (complete appended
tables or include manufacturers constructional
insulation descriptions)
tables or include manufacturers constructional
insulation descriptions)
See below.
-
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
The transformer complied with
clause 13.
clause 13.
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Complied.
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Primary and secondary windings
are isolated by reinforced
insulation
are isolated by reinforced
insulation
Pass
Coil formers and partition walls = 0,4 mm
The bobbin of transformer
measured min. 0.71 mm
measured min. 0.71 mm
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II transformer.
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
No such winding.
N/A
Page 15 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See below.
Pass
Coil formers and partition walls = 0,4 mm
The bobbin of transformer
measured min. 0.71 mm
measured min. 0.71 mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
Same as above.
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high voltage components.
N/A
Component meets category V-1 of IEC 60707
Same as above.
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
Same as above.
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
Same as above.
N/A
14.5
Protective devices
Pass
Protective devices used within their ratings
For model SB 30 CNTR:
T 4.0 AL, 250 V for 100~120 V~;
T 2,0 AL, 250 V for 220-240 V~
For model SB 30 SUB:
T 4.0AL, 250V
For model SB 30 SUB/230:
T 2.5 AL, 250 V
T 4.0 AL, 250 V for 100~120 V~;
T 2,0 AL, 250 V for 220-240 V~
For model SB 30 SUB:
T 4.0AL, 250V
For model SB 30 SUB/230:
T 2.5 AL, 250 V
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
See appended table 13
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such Thermal cut-outs.
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such Thermal links.
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No such devices.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
See table 14.
Pass