Page 12 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm² 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
N/A 
 
Class I protective earthing maintained 
Class II apparatus. 
N/A 
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
(see appended table 11.2) 
Pass 
11.2.5 
Temperature rise of windings 
(see appended table 11.2) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts" 
(see appended table 11.2) 
Pass 
 
12 
MECHANICAL STRENGTH 
12.1.1 
Bump test where mass >7 kg 
Approx.8.7 kg, The apparatus is 
still complying with relevant 
requirements of this standard for 
models SB 30 SUB and SB 30 
SUB/230. 
Pass 
12.1.2 
Vibration test (portable, metal, musical amps) 
The apparatus is still complying 
with relevant requirements of this 
standard. 
Pass 
12.1.3 
Impact hammer test  
No damage to the apparatus 
after the impact test. 
Pass 
 
Steel ball test (for non-ventilated solid areas) 
 
Pass 
12.1.4 
Drop test for portable apparatus where mass = 7 
kg 
Complied with SB 30 CNTR. 
Pass 
12.1.5 
Thermoplastic enclosures stress relief test 
91
o
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
No hazards. 
Pass 
12.3 
Remote controls with hazardous live parts 
No remote control used. 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawer is provided. 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
No antenna coaxial socket is 
provided. 
N/A 
12.6 
Telescoping or rod antennas construction 
No such device. 
N/A 
12.6.1 
Telescoping or rod antennas securement 
No such device. 
N/A 
 
Page 13 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
13.1 
Clearances in accordance with 13.3 
Pollution degree: 2 
Pass 
 
Creepage distances in accordance with 13.4 
See 13.4. 
Pass 
13.2 
Determination of operating voltage 
 
Pass 
13.3 
Clearances 
See below. 
Pass 
13.3.1 
General 
 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
(see appended table 13) 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
(see appended table 13) 
Pass 
 
13.3.4 
Measurement of transient voltages 
 
N/A 
13.4 
Creepage distances 
(see appended table 13) 
Pass 
 
Creepage distances greater than table 11 minima 
Considered. 
Pass 
13.5 
Printed boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
 
Temperature cycle test and dielectric strength test 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 
N/A 
 
 
14 
COMPONENTS 
14.1 
Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such component used. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 
N/A 
 
Page 14 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Resistors separately approved  ............................... :   
N/A 
14.2 
Capacitors and RC units 
Pass 
 
Capacitors separately approved 
 
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... :  Capacitor is min. Y1 type, see list 
of critical components. 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  ... :  Capacitor is min. X2 type, see list 
of critical components. 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ...................... : 
 
N/A 
14.2.5     a)  Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ....................................................................... : 
 
N/A 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ : 
 
N/A 
 
Shielded by a barrier per Table 21 or metal ............ :   
N/A 
14.3 
Inductors and windings 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
Tested with appliance. 
N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... : 
See appended table 14.3.3 
Pass 
 
Transformers and inductors separately approved  . :   
N/A 
14.3.2 
General 
See 14.3.3, 14.3.4 and 14.3.5. 
Pass 
 
Insulation material complies  with clause 20.1.4 
 
Pass 
14.3.3 
Constructional requirements (complete appended 
tables or include manufacturers constructional 
insulation descriptions) 
See below. 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
The transformer complied with 
clause 13. 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
Complied. 
Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Primary and secondary windings 
are isolated by reinforced 
insulation 
Pass 
 
Coil formers and partition walls = 0,4 mm 
The bobbin of transformer  
measured min. 0.71 mm 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II transformer. 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
No such winding. 
N/A 
 
Page 15 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
See below. 
Pass 
 
Coil formers and partition walls = 0,4 mm 
The bobbin of transformer  
measured min. 0.71 mm 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II transformer. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
Same as above. 
N/A 
 
14.4 
High voltage components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No high voltage components. 
N/A 
 
Component meets category V-1 of IEC 60707 
Same as above. 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
Same as above. 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
Same as above. 
N/A 
14.5 
Protective devices 
Pass 
 
Protective devices used within their ratings 
For model SB 30 CNTR: 
T 4.0 AL, 250 V for 100~120 V~; 
T 2,0 AL, 250 V for 220-240 V~ 
For model SB 30 SUB:  
T 4.0AL, 250V 
For model SB 30 SUB/230: 
T 2.5 AL, 250 V 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
See appended table 13 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such Thermal cut-outs. 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such Thermal links. 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No such devices. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
See table 14. 
Pass 
Page of 76