Harman Kardon SB 30 (serv.man3) EMC - CB Certificate ▷ View online
Page 20 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of
IEC 60227-2)
bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Pass
16.5
Adequate strain relief on external flexible cords
Strain relief bushing is used.
Pass
Not possible to push cord back into equipment
Pass
Strain relief device unlikely to damage flexible cord
Pass
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
Class II equipment.
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Pass
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
See below.
Pass
- screws into metal: 5 times
For model SB 30 CNTR and SB
30 SUB:
Metal screw (Ø 3.0 mm) for
metal plate to metal stand. The
screw were 5 time tightened
with the force 0.5Nm
30 SUB:
Metal screw (Ø 3.0 mm) for
metal plate to metal stand. The
screw were 5 time tightened
with the force 0.5Nm
Pass
- screws into non-metallic material: 10 times
For model SB 30 CNTR:
Metal screw (Ø 3.4 mm) for
metal plate to plastic enclosure.
The screw were 10 time
tightened with the force 0.8Nm
For model SB 30 SUB:
Metal screw (Ø 4.37 mm) for
metal plate to Wooden
enclosure. The screws were 10
times tightened with the force
1.8 Nm.
Metal screw (Ø 3.4 mm) for
metal plate to plastic enclosure.
The screw were 10 time
tightened with the force 0.8Nm
For model SB 30 SUB:
Metal screw (Ø 4.37 mm) for
metal plate to Wooden
enclosure. The screws were 10
times tightened with the force
1.8 Nm.
Pass
17.2
Correct introduction into female threads in non-
metallic material
metallic material
Pass
Page 21 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
17.3
Cover fixing screws: captive
See below.
Pass
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
No cause reduction of
clearances and creepage
distance when replaced by
screw with length which is 10
times it‘s diameter.
clearances and creepage
distance when replaced by
screw with length which is 10
times it‘s diameter.
Pass
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
No such part.
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No such electrical connection.
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No screw terminals used for
supply cord.
supply cord.
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
Screws used.
Pass
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable legs or stands.
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Internal pluggable connections
have mechanical securing.
have mechanical securing.
Pass
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION
AGAINST THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
N/A
Picture tube separately approved to 18.1 ................
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. : Approx. 8.6 kg for models SB 30
SUB and SB 30 SUB/230
Pass
Page 22 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Apparatus intended to be fastened in place
–
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
Unit does not overbalance at 10
o
Pass
19.2
100 N force applied vertically downwards
Unit does not overturning.
Pass
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A
19.4
Edges or corners not hazardous
Edges and corners of the
enclosure are rounded.
enclosure are rounded.
Pass
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surfaces.
N/A
19.6
Wall or ceiling mountings adequate
Complied with model SB 30
CNTR.
CNTR.
Pass
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
Pass
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
See below
N/A
b) Exemption for small components as defined in
20.1 mounted on a board of flammability category
of V-1 to IEC 60695-11-10
20.1 mounted on a board of flammability category
of V-1 to IEC 60695-11-10
Components are mounted on a
PCB of V-1.
PCB of V-1.
Pass
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
See sub clause 14 and 20.1.4.
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
Internal PVC wiring working at
voltage less than 4 k
voltage less than 4 k
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
The PCB has the flammability
rating of V-1 min.
rating of V-1 min.
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Not such printed circuit board.
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
The bobbin of transformer has
the flammability rating of V-1.
the flammability rating of V-1.
Pass
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Page 23 of 52
Report No. : 12-1330-0135
IEC/EN 60065
Clause
Requirement
– Test
Result - Remark
Verdict
Apparatus with voltages > 4 kV under normal
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
Open circuit voltage less than 4
kV.
kV.
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
IPX0
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
N/A
Complies with IEC 62151 clause 1
No telecommunication
connection.
connection.
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES
PURPOSES
N/A
L.5.4
Battery chargers and supply apparatus marked
with model number.
with model number.
N/A
Click on the first or last page to see other SB 30 (serv.man3) service manuals if exist.