Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of 
IEC 60227-2) 
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 
Pass 
16.5 
Adequate strain relief on external flexible cords 
Strain relief bushing is used. 
Pass 
 
Not possible to push cord back into equipment 
 
Pass 
 
Strain relief device unlikely to damage flexible cord   
Pass 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
Class II equipment. 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 
Pass 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 
N/A 
 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
17.1 
Torque test to table 20: 
See below. 
Pass 
 
- screws into metal: 5 times 
For model SB 30 CNTR and SB 
30 SUB: 
Metal screw (Ø  3.0 mm) for 
metal plate to metal stand. The 
screw were 5 time tightened 
with the force 0.5Nm 
Pass 
 
- screws into non-metallic material: 10 times 
For model SB 30 CNTR: 
Metal screw (Ø  3.4 mm) for 
metal plate to plastic enclosure. 
The screw were 10 time 
tightened with the force 0.8Nm 
For model SB 30 SUB: 
Metal screw (Ø  4.37 mm) for 
metal plate to Wooden 
enclosure. The screws were 10 
times tightened with the force 
1.8 Nm. 
Pass 
17.2 
Correct introduction into female threads in non-
metallic material 
 
Pass 
 
Page 21 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
17.3 
Cover fixing screws: captive 
See below. 
Pass 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
No cause reduction of 
clearances and creepage 
distance when replaced by 
screw with length which is 10 
times it‘s diameter. 
Pass 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
No such part. 
N/A 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
No such electrical connection. 
N/A 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals used for 
supply cord. 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
Screws used. 
Pass 
17.8 
Fixing devices for detachable legs or stands 
provided 
No detachable legs or stands. 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Internal pluggable connections 
have mechanical securing. 
Pass 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION 
 AGAINST THE EFFECTS OF IMPLOSION 
 
Picture tube separately approved to IEC 61965: 
 
N/A 
 
Picture tube separately approved to 18.1 ................    
N/A 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
N/A 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 
N/A 
 
Protective film as part of implosion protection: 
edges covered by enclosure 
 
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
N/A 
18.2.1 
Samples subject to ageing: 6 
 
N/A 
18.2.2 
Samples subject to implosion test: 6 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
N/A 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
Mass of the equipment exceeding 7 kg  ................. :  Approx. 8.6 kg for models SB 30 
SUB and SB 30 SUB/230 
Pass 
 
Page 22 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Apparatus intended to be fastened in place 
– 
suitable instructions 
 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
Unit does not overbalance at 10
 o
 
Pass 
19.2 
100 N force applied vertically downwards 
Unit does not overturning. 
Pass 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 
N/A 
19.4 
Edges or corners not hazardous 
Edges and corners of the 
enclosure are rounded. 
Pass 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surfaces. 
N/A 
19.6 
Wall or ceiling mountings adequate 
Complied with model SB 30 
CNTR. 
Pass 
 
20 
RESISTANCE TO FIRE 
20.1 
Electrical components and mechanical parts 
Pass 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
See below 
N/A 
 
b) Exemption for small components as defined in 
20.1 mounted on a board of flammability category 
of V-1 to IEC 60695-11-10 
Components are mounted on a 
PCB of V-1. 
Pass 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
See sub clause 14 and 20.1.4. 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
Internal PVC wiring working at 
voltage less than 4 k 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
The PCB has the flammability 
rating of V-1 min. 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
Not such printed circuit board. 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
The bobbin of transformer has 
the flammability rating of V-1. 
Pass 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
N/A 
 
Page 23 of 52 
Report No. : 12-1330-0135 
IEC/EN 60065 
Clause 
Requirement 
– Test 
Result - Remark 
Verdict 
 
 
 
 
Apparatus with voltages > 4 kV under normal 
conditions, and distances to enclosure exceed 
those specified by Table 21, HB40 min enclosure 
 
N/A 
20.2 
Fire enclosure 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
Open circuit voltage less than 4 
kV. 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 
N/A 
 
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
IPX0 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
N/A 
 
 
 
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION 
NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1 
No telecommunication 
connection. 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 
N/A 
 
Complies with IEC 62151 clause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC 
PURPOSES 
N/A 
L.5.4 
Battery chargers and supply apparatus  marked 
with model number. 
 
N/A 
Page of 76
Display

Click on the first or last page to see other SB 30 (serv.man3) service manuals if exist.