Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 37 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
14.12 
- Replace “IEC 61051-2” with “UL 1449” and “IEC 
60707” with “UL 94.” Delete all references to “IEC 
60151”.15.1.1 – Add: “Attachment plug shall 
have a current rating no less than 125% of the 
current drawn under normal operating conditions 
and a voltage rating appropriate for the rated 
voltage of the apparatus. 
Attachment plugs for use on more than one 
supply voltage by means of a voltage selector 
shall be rated for the voltage, which the 
apparatus is intended to be connected when it is 
shipped from the factory. Attachment plug cap 
shall be polarized when the apparatus is 
provided with a manually operated, line 
connected, single-pole switch; Edison-base 
lampholder; or a 15 or 20 A socket outlet.” 
 N 
15.1.2 
- Delete reference to “Banana” plug in the Note. 
Considered. P 
15.1.3.1 
- Add: “An audio amplifier having an open-circuit 
audio output voltage not limited to 120 V that is 
permanently connected to the mains shall be 
provided with a means for connection complying 
with U.21.1.1 – U.21.1.7 and wire-binding screws 
No. 6-32 or larger complying with U.21.3.1 – 
U.21.3.5, or quick-connect 
terminals, or leads. Quick Connect Terminal shall 
comply with the following: a) Male tabs firmly 
mounted in place, b) Mating female connectors 
shall be provided with the apparatus, c) Strain 
Relief Test of Clause 16.5, d) Installation 
instructions shall be provided for assembly of 
terminal to a conductor and strain relief, e) 
Terminals shall be appropriate for use with the 
size and type of wire specified.” 
 N 
15.1.3.2 
- Add: "Audio amplifiers having an audio output 
not limited to 120 V that are connected to the 
mains by a flexible cord shall have suitable cord 
or provision for field installation or a receptacle 
for plug-in connections." 
 N 
15.2 
- Add after 3rd paragraph: “The earthing 
conductor in a supply cord, or in an 
interconnecting cable shall have an equivalent or 
larger cross-sectional area that the current-
carrying conductors in the supply cord or cable. 
With reference to earthing conductors, the 
insulation color may be green or green/yellow. 
Class II type equipment. 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 38 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
15.3.5 
- Revise 2nd paragraph to read: “For rated 
currents exceeding 13 A, reference is made to 
Article 310 of the National Electrical Code, 
ANSI/NFPA 70.” 
Table 15 - Replace with: “Nominal cross-
sectional area AWG“ and modify values. 
No applied for. 
15.4 
- Add: ”Component power supply adaptors 
complying with the construction and test 
requirements of UL 1310, UL 1950 Third Edition, 
or UL 60950 are considered to fulfill the test 
requirements on the clause.” 
Ditto. N 
16.1 
- Modification: Mains supply flexible cords shall 
comply with UL 817, be marked VW-1, and have 
an ampacity not less than the current drawn by 
the apparatus. Delete references to IEC 602227, 
60245 and 60173. 
Table 17A - Add: Types of cords and cord 
lengths for various types of apparatus. 
Ditto. 
16.2 
- An integral earthing conductor shall be at least 
the same size as the other cord conductors. 
Substitute “IEC 60950, table 3B” with “Article 400 
of the National Electrical Code”. 
Table 18 – Replace with “Wire sizes of external 
flexible cords” Upper current limit in column 1 
increased from 16 to 30 A and “AWG” wire sizes 
added. 
Ditto. 
16.3 
- Add: c) Flexible cords not complying with 16.1, 
used as connection between the apparatus and 
other apparatus used in combination with it, shall 
be marked VW-1. 
Ditto. 
17.8 
- Expanded to include all cart/stand parts 
supplied by the manufacturer, such as casters 
and brackets. 
Suitable assembly instructions required. Add: 
"Relevant fixing means are not required when 
installation is to be done by a skilled person." 
Added. P 
17.10 
- Add: Aluminum conductors used as internal 
wiring shall be terminated by a method capable 
of being used in the combination of metals 
involved at the connection point. 
No applied for. 
17.11 
- Add: An accessory shall be investigated to 
determine that: a) The accessory, and the 
combination of the accessory and the apparatus 
shall present no hazard in the sense of this 
standard and b) The accessory is provided with 
installation instructions. 
Considered. P 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 39 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
17.11.1 
- Add: The installation of an accessory of a 
skilled person shall be such that: a) The 
mechanical positioning is accomplished by 
means of tools normally available or by means of 
special tools provided by the organization 
responsible for providing the apparatus as part of 
the installation kit, and b) The electrical 
connections are made by using existing terminals 
and connections in the apparatus or the building 
wiring. 
Added. P 
18 
- Modification: Non-intrinsically protected picture 
tubes shall comply with 18.1, 18.2.2 and 18.3. 
Intrinsically protected picture tubes shall comply 
with UL 1418 or UL 61965. 
Add: “A bulb of a picture tube having a face 
diameter of 7.5 cm or more shall be mounted in 
an enclosure. 
The enclosure shall have no opening that 
exceeds 130 mm2 unless the minor dimension of 
the opening is 10 mm or less.” 
 
No applied for. 
18.1 
- All tubes shall be mounted such that the 
enclosure of the apparatus protects the tube 
against the effects of implosion. Delete reference 
to clause 18.2.  
18.2, 18.2.1, and 18.2.3 are deleted..19 - Add 
reference to 19.2.1. The test of 19.3 is conducted 
on 1) apparatus with direct view CRT with 48 cm 
diagonal min., 2) apparatus, other than a 
speaker, with a mass greater than 47 kg, and 3) 
apparatus, other than a speaker, with a mass or 
25 kg or greater and a height of 1 m or more. The 
tests in 19.1, 19.2 and 19.3 shall not cause the 
apparatus to overturn. During the test of 19.2.1, 
the apparatus shall not slide. 
No CRT. 
19.2.1 
- Add: Slide test requirements. 
No applied for. 
19.3 
– Replace by Horizontal force stability test 
requirements. 
Table 20 – Add values for horizontal force test 
Ditto. N 
19.6. 
-Add: “or equipment rack mounting”. 
Ditto. N 
20.1a 
- Delete 
 N 
20.1b 
- Replace “IEC 60707” with “UL 94” 
Add: “-parts such as protection TV lenses, 
loudspeaker parts, external accessories, and 
fibrous materials less then 0.25 mm thick.” 
Replaced. N 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 40 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
20.1.2 
- Revise text to read: “Sleeving, extruded tubing 
and insulation on wiring shall be rated VW-1 
under following conditions: a) wiring located in a 
circuit that is considered a potential ignition 
source” or b) wiring not located in a circuit that is 
a potential ignition source but is in contact with 
wiring located in a circuit that is a potential 
ignition source. ”Tape should be flame retardant.”
Delete Note and add: “Tape in contact with parts 
of circuits that are potential ignition sources shall 
be flame retardant. 
Considered. N 
20.1.3 
- Replace 1st paragraph with: “Base material of 
printed wiring boards, on which the available 
power as the connection exceeds 15 W or the 
operating voltage exceeds 50 V a.c. or d.c under 
normal operating conditions, shall be of 
flammability category V-1 or better according to 
UL 94.” 
In 2nd paragraph replace “IEC 60707” with “UL 
94” and remove exception for printed boards 
housed in metal enclosures. 
In 3rd paragraph replace “IEC 60707” with “UL 
94” and delete option to use Clause G.1 of Annex 
G. 
Replaced. P 
20.1.4 
- Replace with: “Components and parts shall 
comply with the relevant flammability category 
according to UL 94 as specified in Table 21. 
Delete all other text. 
Replaced. N 
20.1.4 
- Add: “Component power supplies complying 
with the construction and test requirements of UL 
1310, UL 1950 Third Edition, or UL 60950 are 
considered to fulfill the test requirements on the 
clause.” 
Table 21 - Replace complete table with new table 
for “Flammability categories for components and 
parts.” 
No applied for. 
20.2.1 
- Modification: 1st paragraph: “Fire enclosure 
required for 1) circuits and components where 
the available power exceeds 15 W, 2) inductors 
and windings conductively connected to the 
mains and 3) high-voltage products. The fire 
enclosure shall comply with the flammability 
requirements of Table 22 according to UL 94 and 
746C. 2nd, 3rd, and 4th paragraphs are deleted.
In 5th paragraph replace “IEC 60707 or clause 
G.1 of Annex G” with “UL 94 or UL 746C.” 
Table 22 – Add” Flammability categories for fire 
enclosures. 
 