Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 29 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in 
the accordance with the compliance clause 
below and in addition:  
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the 
test voltage of 1,5 kV multiplied by 1,6, and  
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of 
the test see N.2.1). 
 
 
 
A capacitor classified Y3 according to IEC 
60384-14:1993, may bridge this insulation under 
the following conditions: 
-the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition 
to the Y3 testing, is tested with an Impulse test of 
2.5kV defined in IEC 62151, subclause 6.2.1;  
- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-
14;  
-the Impulse test of 2.5kV is to be performed 
before the Endurance Test in IEC 60384-14 in 
the sequence of tests as described in IEC 60384-
14.  
No applied for. 
 
Subclause 5.3.2 (Corrigendum 1):  
Add after the fourth dash: 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to 
the building installation wiring using screw 
terminals or other reliable means, and for 
equipment which is intended for connection to 
the building installation wiring via an industrial 
plug and  socket -outlet or an appliance coupler, 
or both, complying with IEC 60309 or with a 
comparable national standard. 
Ditto. N 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 30 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
US 
1.1.1 
– Scope clarification: The standard also covers 
commercial and professional apparatus; 
professional apparatus may also be investigated 
using UL 1419. Projection apparatus is not 
covered. Household games, household gaming 
and scoring machines, satellite receiver antenna 
positioners are covered by this standard but 
commercial games and commercial gaming and 
scoring machines, and other types of antenna 
positioners are covered by other standard.  
Add: Mains connected apparatus intended for 
field installation requires compliance with the 
National Electrical Code, ANSI, NFPA 70. 
 
1.1.3 
- Protection against splashing water replaced 
with apparatus intended for outdoor use (See 
Annex A). 
Considered. N 
1.1.5 
- Add: Some equipment covered by these 
requirements may also be required to comply 
with applicable requirements in other standards 
No apply for. 
1.2 
- Add references to ANSI, ASTM and UL 
standards. 
Ditto. N 
4.2.1 
- Add Note: In the U.S. the RATED SUPPLY 
VOLTAGE for single-phase apparatus is 
assumed to be 120 V or 120/240 V. 
Ditto. N 
4.2.4 
- Revision to sub-clause a): Minimum audio 
output is not less than 0.5 W per channel unless 
the maximum audio output is less than 0.5 W per 
channel. 
No applied for. 
4.2.4.1 
– Add: “An apparatus with multiple modes of 
operation, multiple signal input sources, or both, 
is to be operated using each mode of operation 
or signal input source separately, or in 
combination, according to the manufacturer’s 
instructions to produce the maximum power 
input”. Table 2: External supply sources are 
assumed to be capable of delivering 30 A, unless 
otherwise specified (no-load voltage and internal 
resistance values in the Table are modified). 
Ditto. N 
4.3.4 
– Add: PTC thermistors may also comply with UL 
1434. 
Ditto. N 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 31 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
5.1 
– Add: Component power supplies and adapters 
complying with the construction and test 
requirements of UL 1310, UL 1950, or UL 60950 
fulfill the requirements of items “a” through “i” of 
this clause. 
It should be considered when 
national approval. 
5.1f 
– Add: Rated frequency is required on all 
apparatus 
Added. P 
5.1g 
- Add: Rated current or power required on all 
apparatus. 
Added. P 
5.1j 
- Add: Date of Manufacture” marking required on 
all apparatus. 
 N 
5.1k 
- Add: Manufacturing identification marking 
required. 
 
5.1l 
- Add: Combination of two graphical symbols and 
supplementary marking is required. 
 
5.1m 
- Add: Equipment rack marking required for 
audio/video systems. 
 
5.1n 
- Add: Units having leakage current levels greater 
than 0.75 MIU and equal to or less than 3.5 MIU 
must be marked with a high leakage current 
marking. 
 
5.2c 
– Modification: Output terminals must be marked 
with voltage, frequency and current or power; 
output terminals installed or interconnected in the 
field must be marked with the class of wiring. 
No applied for. 
5.2d 
- Add: Audio output connections shall be marked 
“Class 1 Wiring”, “Class 2 Wiring” or “Class 3 
Wiring”. Operation manual shall discuss risks 
and proper connecting and insulating techniques 
when connecting a speaker. 
Ditto. 
5.3 
- Add: "An explanation and illustration of safety 
related graphical symbols used on the apparatus 
shall be included in the owner’s instructions 
preceding any operating instructions. 
 P 
5.4 
– Add: Important Safety Instructions are to be 
packed with each apparatus and shall be 
verbatim. 
Added. P 
5.4.1 
– Add: Warning about Outdoor Use is required. 
Ditto. 
5.4.3 –
 
Add: When apparatus contains instructions for 
use by service personnel the instructions are 
separate in format and preceded by a 
precautionary warning statement. 
 N 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 32 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
6.1 
- Starting from second paragraph replace all by: 
"Compliance is checked in accordance with the 
requirements in the U.S. Code of Federal 
Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, and 1020.10 by 
measuring the radiation produced by the 
apparatus employing a design center chassis." 
See last page. 
6.2 
- Starting from second paragraph replace all by: 
"Apparatus shall be classified and labeled in 
accordance with the Code of Federal 
Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, 1040.10 and 1040.11."
Ditto. N 
6.2.2 
- Deleted Table 3: Temperature limits added for 
various classes of insulation systems. Add to 
Note a): "Materials rated in accordance with UL 
746B may be used at their rated higher 
temperature.".7.2 – Add: A material temperature 
rating can be accepted in lieu of the softening 
temperature. The softening test need not be 
performed on materials used in UL Listed or 
Recognized parts. 
No applied for.  
8.1 
- Add: “A metal part that is not inherently 
resistant to corrosion shall be protected against 
corrosion when corrosion of that part is capable 
of contributing to or resulting in a risk of fire, 
shock, or injury to persons.” 
 N 
8.9.1 
– Add: “Sleeving, tape, tubing, and wire 
insulation are suitable for the conditions of use, 
such as voltage and temperature, and comply 
with UL 224, UL 510, and UL 1441, as 
applicable.” 
No applied for. 
8.10 
– Add: “Component power supplies and their 
internal insulation complying with the 
construction and test requirements of UL 1310, 
UL 1950 Third Edition, or UL 60950 are 
considered to fulfill the test requirements on the 
clause.” 
Ditto. N 
8.12 
– Modification: Conductors and internal wiring 
connecting mains socket-outlets shall comply 
with the wire size requirements in clause 16.2 
based on the marked rating of the outlet but shall 
not be less than 18 AWG. 
Ditto. N 
8.17 
– Add: As an option, winding wire insulation may 
comply with the requirements in UL Subject 
2353. 
Ditto. N 
8.19.1 
– Modification: An all-pole switch or circuit 
breaker is not required to have contact 
separation of 3 mm. 
Considered. P 
Page of 52