Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 25 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
J.2 
After Table J.1 the following is added: In Norway, 
due to the IT power distribution system used, the 
a.c. MAINS supply voltage is considered to be 
equal to the line-to-line voltage, and will remain 
230 V in case of a single earth fault. 
Justification
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
Considered. P 
Annex B 
Replace NOTE 1 by  
In the CENELEC countries listed in IEC 62151, 
special national conditions apply.  
Add the following:  
All subclauses given below are subclauses of 
IEC 62151:2000 (ref. Corrigendum 1 and 2 to 
IEC 62151).  
Replaced. P 
 
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph:  
NOTE - In Norway, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet.  
The marking text shall be as follows:  
"Apparatet skal tilkoples jordet stikkontakt"  
Subclause 5.3.1 (Corrigendum 1):  
Add after the first test specifications paragraph:  
Added. P 
 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2.  
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is 
added between the first and second paragraph 
(this text is identical to the text in EN 60950-
1:2001):  
No TNV circuit. 
 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 26 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either  
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or - 
one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below.  
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES 
do not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
 
 
 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the 
test voltage of 1,5 kV multiplied by 1,6, and  
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of the test see N.2.1).  
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2.  
No applied for.  
 
 
 
A capacitor classified Y3 according to IEC 
60384-14:1993, may bridge this insulation under 
the following conditions:  
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition 
to the Y3 testing, is tested with an Impulse test of 
2.5kV defined in IEC 62151, subclause 6.2.1;  
- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-
14;  
- the Impulse test of 2.5kV is to be performed 
before the Endurance Test in IEC 60384-14 in 
the sequence of tests as 
described in IEC 60384-14.  
No applied for.  
 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 27 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
 
Subclause 5.3.2 (Corrigendum 1):  
Add after the fourth dash: 
NOTE -In Norway, exclusions are applicable for 
equipment which is intended for connection to 
the building installation 
wiring using screw terminals or other reliable 
means, and for equipment which is intended for 
connection to the building installation wiring via 
an industrial plug and socket -outlet or an 
appliance coupler, or both, complying with IEC 
60309 or with a comparable national standard. 
No applied for. 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 28 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
SE 
Annex B 
Replace NOTE 1 by  
In the CENELEC countries listed in IEC 62151, 
special national conditions apply.  
Add the following:  
All subclauses given below are subclauses of 
IEC 62151:2000 (ref. Corrigendum 1 and 2 to 
IEC 62151).  
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph:  
Replaced. P 
 
NOTE - In Sweden, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet.  
The marking text shall be as follows:  
"Apparaten skall anslutas till jordat uttag”  
Subclause 5.3.1 (Corrigendum 1):  
Add after the first test specifications paragraph:  
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2.  
No mains sock-outlet. 
 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation.  
Renumber the existing note as note 2.  
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is 
added between the first and second paragraph 
(this text is identical to the text in EN 60950-
1:2001):  
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either  
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or  
- one layer having a distance through insulation 
of at least 0,4 mm, which shall pass the electric 
strength test below.   
No applied for. 