Harman Kardon SB 16 (serv.man9) EMC - CB Certificate ▷ View online
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 21 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
DK
2.6.1
The following is added: Certain types of CLASS I
apparatus, see 15.1.1, may be provided with a
plug not establishing earthing continuity when
inserted in Danish socket-outlets J
apparatus, see 15.1.1, may be provided with a
plug not establishing earthing continuity when
inserted in Danish socket-outlets J
ustification:
Heavy Current Regulations, Section 107
It should be considered when
national approval.
national approval.
N
15.1.1
To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-
D1.
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-
D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with the Heavy Current Regulations
Section 107-2-D1 standard sheet DK 2-1a.
outlets with earth contact or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with the Heavy Current Regulations
Section 107-2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2,5 A
shall have the following demensions:
CLASS II apparatus with a rated current of 2,5 A
shall have the following demensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with the Heavy Current
Regulations, Section 107-2-D1, Standard Sheet
DK 1-3a, DK 1-5a or DK 1-7a.
Mains socket-outlets with earthing contact shall
be in compliance with the Heavy Current
Regulations, Section 107-2-D1, Standard Sheet
DK 1-3a, DK 1-5a or DK 1-7a.
Justification:
Heavy Current Regulations, Section 107
Heavy Current Regulations, Section 107
Ditto. N
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 22 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
GB
15.1.1
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
Justification:
SI 1768: 1994
No power core provided.
N
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 23 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
MY
Energy Commission circular no.1 year 2003
(no.1/2003)
States that a Certificate of Approval is required
for manufacturing, selling,
Advertising, displaying or importing into Malaysia,
electrical/electronic products
Listed in Annex A.
-The supply voltage in Malaysia is 240 Vac, at
50Hz.
(no.1/2003)
States that a Certificate of Approval is required
for manufacturing, selling,
Advertising, displaying or importing into Malaysia,
electrical/electronic products
Listed in Annex A.
-The supply voltage in Malaysia is 240 Vac, at
50Hz.
-Class 0 and 01 appliances are not allowed
-13A fused plug-tops shall comply to Malaysian
standard (MS 589:Part1:1997), if applicable.
standard (MS 589:Part1:1997), if applicable.
-2-pin plug tops shall comply to Malaysian
standard (MS 1578:2003) if applicable
standard (MS 1578:2003) if applicable
It should be considered when
national approval.
national approval.
N
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 24 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
NO
13.3.1
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault. J
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault. J
ustification: Based on a use in Norway of
an IT power distribution system where the neutral
is not provided.
is not provided.
Consider
P
15.1.1
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065.
electronic apparatus are tested as specified in
12.1.3 of EN 60065.
Also the protecting rim shall be tested.
Justification:
Act of 24 May 1929 relating to supervision of
electrical installation (TEA 1929/FEL 1998).
electrical installation (TEA 1929/FEL 1998).
No mains socket-outlets.
N
Click on the first or last page to see other SB 16 (serv.man9) service manuals if exist.