DOWNLOAD Harman Kardon SB 16 (serv.man9) Service Manual ↓ Size: 396.28 KB | Pages: 52 in PDF or view online for FREE

Model
SB 16 (serv.man9)
Pages
52
Size
396.28 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-16-sm9.pdf
Date

Harman Kardon SB 16 (serv.man9) EMC - CB Certificate ▷ View online

 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 21 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
DK 
2.6.1 
The following is added: Certain types of CLASS I 
apparatus, see 15.1.1, may be provided with a 
plug not establishing earthing continuity when 
inserted in Danish socket-outlets J
ustification: 
Heavy Current Regulations, Section 107 
It should be considered when 
national approval. 
15.1.1 
To the first paragraph the following is added:  
In Denmark, supply cords of single phase 
appliances having a rated current not exceeding 
13 A shall be provided with a plug according to 
the Heavy Current Regulations Section 107-2-
D1. 
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended 
to be used in locations where protection against 
indirect contact is required according to the 
wiring rules shall be provided with a plug in 
accordance with the Heavy Current Regulations 
Section 107-2-D1 standard sheet DK 2-1a.  
To the second paragraph the following is added:
Socket outlets intended for provided power to 
CLASS II apparatus with a rated current of 2,5 A 
shall have the  following demensions:  
Dimensions in mm  
Other dimensions shall be in compliance with the 
Heavy Current Regulations, Section 107-2-D1, 
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.  
To the third paragraph the following is added: 
Mains socket-outlets with earthing contact shall 
be in compliance with the Heavy Current 
Regulations, Section 107-2-D1, Standard Sheet 
DK 1-3a, DK 1-5a or DK 1-7a.  
Justification:  
Heavy Current Regulations, Section 107 
Ditto. N 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 22 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
GB 
15.1.1 
Apparatus which is fitted with a flexible cable or 
cord and is designed to be connected to a mains 
socket conforming to BS 1363 by means of that 
flexible cable or cord and plug shall be fitted with 
a ”standard plug” in accordance with Statutory 
Instrument 1768: 1994: The Plugs and Sockets 
etc. (Safety) Regulations 1994, unless exempted 
by those Regulations.  
NOTE ”Standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved 
conversion plug.  
Justification:  
SI 1768: 1994 
No power core provided. 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 23 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
MY 
 
Energy Commission circular no.1 year 2003 
(no.1/2003)  
States that a Certificate of Approval is required 
for manufacturing, selling, 
Advertising, displaying or importing into Malaysia, 
electrical/electronic products 
Listed in Annex A. 
-The supply voltage in Malaysia is 240 Vac, at 
50Hz.  
-Class 0 and 01 appliances are not allowed  
-13A fused plug-tops shall comply to Malaysian 
standard (MS 589:Part1:1997), if applicable.  
-2-pin plug tops shall comply to Malaysian 
standard (MS 1578:2003) if applicable 
It should be considered when 
national approval. 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 24 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
NO 
13.3.1 
To the second paragraph the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. J
ustification: Based on a use in Norway of 
an IT power distribution system where the neutral 
is not provided. 
Consider  
15.1.1 
Mains socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as fas as a Applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2,5 A 250 V two-pole socket-outlets for 
electronic apparatus shall comply with the 
enclosed Standard Sheet I. 
 
§ 24 Mechanical strength 
a 2,5 A, 250 V socket-outlets for CLASS II 
electronic apparatus are tested as specified in 
12.1.3 of EN 60065. 
Also the protecting rim shall be tested. 
Justification:  
Act of 24 May 1929 relating to supervision of 
electrical installation (TEA 1929/FEL 1998). 
No mains socket-outlets. 
 
Page of 52
Display

Click on the first or last page to see other SB 16 (serv.man9) service manuals if exist.