Harman Kardon SB 16 (serv.man9) EMC - CB Certificate ▷ View online
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 17 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
17.9A.1
Adhesive securement
The following parts, the displacement of which
may result in a fire or shock hazard, shall not be
secured solely by adhesive, unless the adhesive
system complies with the resistance to external
forces test of Clause 9.1.7, the bump test of
Clause 12.1.1, and the impact test of Clause
12.1.3, after conditioning in accordance with
Clause 17.9A.2:
a) internal metal parts/conductive coatings;
b) barriers; and
c) required enclosure parts.
Note:
may result in a fire or shock hazard, shall not be
secured solely by adhesive, unless the adhesive
system complies with the resistance to external
forces test of Clause 9.1.7, the bump test of
Clause 12.1.1, and the impact test of Clause
12.1.3, after conditioning in accordance with
Clause 17.9A.2:
a) internal metal parts/conductive coatings;
b) barriers; and
c) required enclosure parts.
Note:
Cathode ray tubes are excluded from this
test.
Not applied for.
N
17.9A.2
Adhesive and conductive coating securement
conditioning
conditioning
Ditto. N
17.9A.2.1 General
Where required by Clause 17.9A.1, one sample
of the apparatus or enclosure section shall be
conditioned in accordance with the requirements
of Clause 17.9A.2.2. Equivalent aging test data
supplied by the manufacturer may be considered
in lieu of aging.
of the apparatus or enclosure section shall be
conditioned in accordance with the requirements
of Clause 17.9A.2.2. Equivalent aging test data
supplied by the manufacturer may be considered
in lieu of aging.
Ditto. N
17.9A.2.2
Day 1: Place sample in oven at 100 ± 1EC for 1
week, or 82 ± 1EC for 8 weeks, at the
manufacturer’s option.
Day 8 or day 57:
week, or 82 ± 1EC for 8 weeks, at the
manufacturer’s option.
Day 8 or day 57:
1. Remove from oven and leave at room
temperature for 1 h.
1. Place in freezer at –35 EC for 2 h.
1. Remove from freezer and allow to reach
room temperature overnight.
Ditto. N
Day 9 or day 58:
1
Place in a compartment at 96% relative
humidity for 3 h.
humidity for 3 h.
1
Remove and leave at room temperature
and humidity for 1 h.
and humidity for 1 h.
1
Place in oven at a temperature selected
in the first cycle for 3 h.
in the first cycle for 3 h.
1
Remove and allow to come to room
temperature overnight.
temperature overnight.
Ditto. N
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 18 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
Day 10 or day 59:
1
Place in freezer at –35 EC for 2 h.
1
Remove and leave at room temperature
for 1 h.
for 1 h.
1
Place in humidity chamber at 96%
relative humidity for 3 h.
relative humidity for 3 h.
1
Remove and allow to come to room
temperature overnight.
temperature overnight.
Not applied for.
N
Day 11 or day 60:
1. Place in oven at the temperature
selected in the first cycle for 3 h.
1. Remove for 1 h.
1. Place in freezer at –35 EC for 2 h.
1. Remove and allow to come to room
temperature overnight.
Ditto. N
Day 12 or day 61:
1. Place in humidity chamber at 96%
relative humidity for 3 h.
1. Remove and perform mechanical tests
as required by Clause 17.9A.1 as
applicable.
applicable.
Ditto. N
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
P
18.1A
[Add the following clause]
A picture tube with a maximum face dimension
exceeding 75 mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965,
or the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
exceeding 75 mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965,
or the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
Not applied for.
N
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 19 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
19
Stability and mechanical hazards
[Add the following after the second paragraph]
The test of Clause 19.3 is only required for
a) apparatus with a mass of 25 kg or more;
b) apparatus, excluding loudspeaker systems,
with a height of 1 m or more; or
with a height of 1 m or more; or
c) apparatus, including loudspeaker systems, in
combination with a supplied or recommended
cart or stand with a total height of 1 m or more.
combination with a supplied or recommended
cart or stand with a total height of 1 m or more.
[Add the following paragraph]
Apparatus not tested because it is intended to be
fastened in place shall be provided with the
following warning, marked on the apparatus or
on a durable label attached to the mains cord:
“WARNING: This apparatus must be securely
attached to the floor/wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury/death.”
fastened in place shall be provided with the
following warning, marked on the apparatus or
on a durable label attached to the mains cord:
“WARNING: This apparatus must be securely
attached to the floor/wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury/death.”
Considered. P
20.2
Fire enclosure
See below.
P
20.2.1A
[Add the following clause]
Enclosures of apparatus containing high-voltage
or projection lamps shall have a minimum
flammability rating of category FV 1 according to
IEC 60707 at the minimum thickness used.
or projection lamps shall have a minimum
flammability rating of category FV 1 according to
IEC 60707 at the minimum thickness used.
No high- voltage or project
lamps.
lamps.
N
Annex B
(normative)
(normative)
Apparatus to be connected to the
telecommunication networks
[Replace this annex with the following]
telecommunication networks
[Replace this annex with the following]
Apparatus intended for direct connection to a
telecommunication network shall comply with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.
telecommunication network shall comply with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.
No applied for.
N
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 20 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
DE
5
The following markings are required:
a) In case of intrinsically ionizing radiation safe
cathode-ray tubes with accelerating voltages
between 20 Kv and 30 Kv:
cathode-ray tubes with accelerating voltages
between 20 Kv and 30 Kv:
-On the cathode-ray tube itself the wording:
Eigensicheere Kathodenstrahlröhre nach Anlage
III Röntgen-verordnung.
Eigensicheere Kathodenstrahlröhre nach Anlage
III Röntgen-verordnung.
-Inside the apparatus:
the maximum allowed accelerating voltage in Kv,
and the maximum allowed beam current in Ma.
the maximum allowed accelerating voltage in Kv,
and the maximum allowed beam current in Ma.
-On the outer of the apparatus:
a notice in German language that produced X-
rays are sufficiently shielded by the intrinsically
safe cathode-ray tube.
a notice in German language that produced X-
rays are sufficiently shielded by the intrinsically
safe cathode-ray tube.
b) In case of approval of the whole TV receiver
with an accelerating voltage exceeding 20 Kv:
with an accelerating voltage exceeding 20 Kv:
-On the outer of the apparatus:
the licence number …/…/…/Rö, and the following
text:
the licence number …/…/…/Rö, and the following
text:
Die in diesem Gerät entstehende
Röntgenstrahlung ist ausreichend abgeschirmt.
Beschleunigungsspannung: max: … Kv.
Röntgenstrahlung ist ausreichend abgeschirmt.
Beschleunigungsspannung: max: … Kv.
-Supplied with the apparatus:
a copy of “Zulassungsschein”, together with the
notices required there.
a copy of “Zulassungsschein”, together with the
notices required there.
c) In case of TV receivers with accelerating
voltages not exceeding 20 Kv:
voltages not exceeding 20 Kv:
Die in diesem Gerät entstehende
Röntgenstrahlung ist ausreichend abgeschirmt.
Röntgenstrahlung ist ausreichend abgeschirmt.
Beschleunigungsspannung: max: … Kv.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), dated
1987-01-08.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), dated
1987-01-08.
NOTE The German nimisterial decree
(Röntgenverordnung) is under revision.
(Röntgenverordnung) is under revision.
No CRT
No TV receivers.
No TV receivers.