Harman Kardon SB 16 (serv.man9) EMC - CB Certificate ▷ View online

 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 17 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
17.9A.1 
Adhesive securement  
The following parts, the displacement of which 
may result in a fire or shock hazard, shall not be 
secured solely by adhesive, unless the adhesive 
system complies with the resistance to external 
forces test of Clause 9.1.7, the bump test of 
Clause 12.1.1, and the impact test of Clause 
12.1.3, after conditioning in accordance with 
Clause 17.9A.2:  
a) internal metal parts/conductive coatings;  
b) barriers; and  
c) required enclosure parts. 
Note: 
Cathode ray tubes are excluded from this 
test. 
Not applied for. 
17.9A.2 
Adhesive and conductive coating securement 
conditioning 
Ditto. N 
17.9A.2.1 General 
 
Where required by Clause 17.9A.1, one sample 
of the apparatus or enclosure section shall be 
conditioned in accordance with the requirements 
of Clause 17.9A.2.2. Equivalent aging test data 
supplied by the manufacturer may be considered 
in lieu of aging. 
Ditto. N 
17.9A.2.2 
Day 1: Place sample in oven at 100 ± 1EC for 1 
week, or 82 ± 1EC for 8 weeks, at the 
manufacturer’s option. 
Day 8 or day 57:  
1.  Remove from oven and leave at room 
temperature for 1 h.  
1.  Place in freezer at –35 EC for 2 h.  
1.  Remove from freezer and allow to reach 
room temperature overnight. 
 
Ditto. N 
 
Day 9 or day 58:  
 Place in a compartment at 96% relative 
humidity for 3 h.  
 Remove and leave at room temperature 
and humidity for 1 h.  
Place in oven at a temperature selected 
in the first cycle for 3 h. 
 Remove and allow to come to room 
temperature overnight.  
 
Ditto. N 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 18 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
 
Day 10 or day 59: 
 Place in freezer at –35 EC for 2 h.  
 Remove and leave at room temperature 
for 1 h.  
 Place in humidity chamber at 96% 
relative humidity for 3 h.  
 Remove and allow to come to room 
temperature overnight.  
 
Not applied for. 
 
Day 11 or day 60: 
1.  Place in oven at the temperature 
selected in the first cycle for 3 h.  
1.  Remove for 1 h.  
1.  Place in freezer at –35 EC for 2 h.  
1.  Remove and allow to come to room 
temperature overnight.  
 
Ditto. N 
 
Day 12 or day 61: 
1.  Place in humidity chamber at 96% 
relative humidity for 3 h.  
1.  Remove and perform mechanical tests 
as required by Clause 17.9A.1 as 
applicable.  
 
Ditto. N 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
18.1A 
[Add the following clause]  
A picture tube with a maximum face dimension 
exceeding 75 mm either shall be intrinsically 
protected with respect to effects of implosion and 
to mechanical impact, in accordance with 
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965, 
or the enclosure of the apparatus shall provide 
adequate protection against the effects of an 
implosion of the tube (see Clause 12). 
Not applied for. 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 19 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
19  
Stability and mechanical hazards  
[Add the following after the second paragraph]  
The test of Clause 19.3 is only required for  
a) apparatus with a mass of 25 kg or more;  
b) apparatus, excluding loudspeaker systems, 
with a height of 1 m or more; or  
c) apparatus, including loudspeaker systems, in 
combination with a supplied or recommended 
cart or stand with a total height of 1 m or more.  
[Add the following paragraph]  
Apparatus not tested because it is intended to be 
fastened in place shall be provided with the 
following warning, marked on the apparatus or 
on a durable label attached to the mains cord:  
“WARNING: This apparatus must be securely 
attached to the floor/wall per installation 
instructions. Tipping, shaking, or rocking the 
machine may cause injury/death.” 
Considered. P 
20.2 
Fire enclosure 
See below. 
20.2.1A 
[Add the following clause]  
Enclosures of apparatus containing high-voltage 
or projection lamps shall have a minimum 
flammability rating of category FV 1 according to 
IEC 60707 at the minimum thickness used. 
No high- voltage or project 
lamps. 
 
 
Annex B 
(normative) 
Apparatus to be connected to the 
telecommunication networks 
 
[Replace this annex with the following]  
Apparatus intended for direct connection to a 
telecommunication network shall comply with 
a) Clause 19 of CSA C22.2 No. 1; or 
b) CAN/CSA-C22.2 No. 60950. 
No applied for. 
 
 
 
 
 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 20 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
DE 
The following markings are required:  
a) In case of intrinsically ionizing radiation safe 
cathode-ray tubes with accelerating voltages 
between 20 Kv and 30 Kv:  
-On the cathode-ray tube itself the wording:  
Eigensicheere Kathodenstrahlröhre nach Anlage 
III Röntgen-verordnung. 
-Inside the apparatus:  
the maximum allowed accelerating voltage in Kv, 
and the maximum allowed beam current in Ma.  
-On the outer of the apparatus:  
a notice in German language that produced X-
rays are sufficiently shielded by the intrinsically 
safe cathode-ray tube. 
b) In case of approval of the whole TV receiver 
with an accelerating voltage exceeding 20 Kv:  
-On the outer of the apparatus:  
the licence number …/…/…/Rö, and the following 
text:  
Die in diesem Gerät entstehende 
Röntgenstrahlung ist ausreichend abgeschirmt.  
Beschleunigungsspannung: max: … Kv.  
 
-Supplied with the apparatus:  
a copy of “Zulassungsschein”, together with the 
notices required there.  
c) In case of TV receivers with accelerating 
voltages not exceeding 20 Kv:  
Die in diesem Gerät entstehende 
Röntgenstrahlung ist ausreichend abgeschirmt.  
Beschleunigungsspannung: max: … Kv. 
Justification: German ministerial decree against 
ionizing radiation (Röntgenverordnung), dated 
1987-01-08.  
NOTE The German nimisterial decree 
(Röntgenverordnung) is under revision. 
No CRT 
 
 
 
 
 
 
 
 
 
 
No TV receivers. 
 
 
 
 
 
 
 
 
 
No TV receivers. 
 