Harman Kardon HKTS 7 (serv.man3) EMC - CB Certificate ▷ View online

 
Page 27 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
11.2 TABLE: 
summary 
of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage ........ : 
220-230 
— 
 Frequency 
(Hz)................................................... : 
50/60 
— 
 Ambient 
temperature 
(
o
C) ................................. :  22 
— 
No 
Component 
Fault 
Temp Rise/ 
Component 
Other results 
(include description and test duration) 
1 Apparatus 
Pmax 
78K/prim.winding 
68-
72K/sec.windings 
53K/PCB 
48/heat sink on rear 
panel 
44K/rear metal encl.
Un=253V, Pn= 104W, In= 0.55A.  
Test time= 4h. 
No high temperatures, no remarks. 
Q105 
sc -- 
Un=253V. Q107 and Q108 broke, mains fuse 
opened immediately. No high temperatures, no 
remarks. 
3 Q107 sc 
-- 
Un=253V. Q107 and Q108 broke, mains fuse 
opened immediately. No high temperatures, no 
remarks. 
4 C133 sc 
-- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
5 D115 
(  - +) 
sc 
-- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
D110 
(  - +) 
sc -- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
C122 
sc -- 
Un=198V, Pn = 525-0W, In = 2.5-0A  
After 2min. conductors on the PCB were 
interrupted, rectifier D110 broke and mains fuse 
opened. Test time: 3min. No high temperatures, 
no remarks. (see next fault case) 
C122 
sc -- 
Un=198V, Pn = 640W, In = 3.4A. Interrupted 
conductors were bridged and mains fuse replaced 
with T2.5AL. Original fuse T1.25AL considered 
opened due to the high In; test aborted after 3s.   
No high temperatures, no remarks. 
 
Page 28 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  220-230 V 
Pollution degree: 
II 
Material Group: 
IIIb 
2 N force on internal parts applied: 
30 N force on outside of conductive enclosure applied: 
 
 
Location 
 
Operating Voltage 
 
Clearance (mm) 
 
Creepage (mm) 
 
 
V rms 
 
V peak 
 
Min 
 
Actual 
 
Min 
 
Actual 
 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
 
Primary (ac) to Earth (B) 
 
 
 
 
 
 
 
Primary (+dc) to Earth max (B) 
 
 
 
 
 
 
 
Primary (-dc) to Earth max (B) 
 
 
 
 
 
 
 
Across mains fuse (B) 
 
230 
 
345 
 
2.0 
 
8.2 
 
2.3 
 
8.2 
Across primary directly connected to 
the mains (B) 
 
230 
 
345 
 
2.0 
 
7.0 
 
2.3 
 
7.0 
 
Hazardous live secondary to Earth (B)
 
 
 
 
 
 
Optocoupler input to output (R) 
 
 
 
 
 
 
Primary to Secondary red  in 
transformer (R) 
 
296 
 
418 
 
4.0 
 
>10 
 
6.3 
 
8.1 
Primary to Secondary yellow (R) 
 
263 
 
372 
 
4.0 
 
>10 
 
5.4 
 
>8.1 
Primary to accessible conductive 
parts (R) 
 
230 
 
345 
 
4.0 
 
>10 
 
4.6 
 
7.0 
Hazardous live secondary to non-
hazardous live secondary (R) 
 
 
 
 
 
 
Hazardous live secondary to 
unearthed conductive enclosure (R) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance . 
 
"Min" = minimum required.
 
"Actual = Actual dimensions measured. 
 
 
Page 29 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Mains Transformer 
Transtec 
TT0869803320
AC 230V, 50Hz 
IEC 60065 
— 
Thermal link 
Joint Force 
M33 
2A, 250V, 130
°C
IEC 60691 
TÜV 
Alt. Mains Transformer 
Transtec 
TT0869803320-E
AC 230V, 50Hz 
IEC 60065 
— 
Alt. Thermal link 
Joint Force 
L33 
2A, 250V, 130
°C
IEC 60691 
TÜV 
Bobbins Transformer 
EI Dupont de 
Nemours 
Nylon 66  
101, 101F 
Min. HB75 
Complies with 
IEC 60707
 
HB75 
— 
Mains Fuse 
Walter 
TSD 
T1.25AL 250V 
IEC 60127 
 
Mains fuseholder 
Chin Shin 
(Walter) 
R3-11 
Min. FV 1 
Complies with 
IEC 60707      
HB75 
__ 
Mains switch 
CHILY 
3024 
16(4) 8/128A, 
250V Class II 
IEC 61058-1 
IEC60065:2001
Sub-clause 
14.6 1a) 
FI 
Plug 
I Sheng 
SP-021A 
2.5A   250V 
CEE 7 
Cord 
 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
 
 
Luen Tai 
Electric 
 
9518 
 
13A   250V 
 
BS 1363 
 
BSI 
For UK: 
Plug with fuse 
 
Cord 
Rhythm Wire 
Ind. Co., Ltd. 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
KEMA 
 
MP2217 
 
3A   250V 
 
KS C8305 
For Korea 
Plug 
Cord 
Volex 
VCTFK 
2 x 0.75mm² 
KS C3304 
 
Sec. Connector P103 
JWT 
A3963Wv2-5P 
V-1 
Complies with 
IEC 60707
 
HB75 
— 
Jian He 
(Cheng Ho) 
Various 
PCB 
 
Alt. 
Hsiang Kuo 
FR-1 or FR-4 
V-1 
Complies with 
IEC 60707      
HB75 
— 
Plastic Enclosure 
Shin-bo Plastic
Molding Corp 
PA-764 
Min. FV 1 
Complies with 
IEC 60707     
HB75 
— 
 
Page 30 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
Shrink tubing, 
covering mains switch 
and inlet  
Dongguan 
Quantai 
T-2 VW-1 
Complies with 
IEC 60707     
HB75 
— 
 
 
Group differences  
IEC 60065:2001          
                                                                
CB Bulletin 110A / GRP 06  I
 
 
Contents 
Add the following annexes: 
Annex ZA (normative) Other international publications quoted in this standard 
with the references of the relevant European publications (See the CB Bulletine) 
Annex ZB (nominative) Special national conditions 
Annex ZC (informative) A-deviations  
3.1 
Add the following indent at the end of the list 
Exposure to excessive sound pressures 
from headphones or earphones 
NOTE  A new method of measurement is described in 
EN 50332-1, Sound system equipment: Headphones 
and earphones associated 
with portable audio equipment – Maximum sound 
pressure level measurement methodology and limit 
considerations – Part 1: General 
method for ”one package equipment”, and in EN 
50332-2, Sound system equipment: Headphones and 
earphones associated with 
portable audio equipment – Maximum sound pressure 
level measurement methodology and limit 
considerations – Part 2: Guidelines to 
associate sets with headphones coming from different 
manufacturers. 
 N/A 
4.1.1 
Replace 
the text of the note by: 
NOTE For ROUTINE TEST reference is made to EN 
50333
 P 
5.1.i) 
Add 
the following note: 
NOTE For RATED POWER CONSUMPTION 
mesurements of TVs reference is made to EN 60107. 
 N/A 