Page 39 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
 
National differences  Norway 
IEC 60065:2001 
(See also Group Differences)            
                                                                
CB Bulletin 110A / NO  06  I
 
 
13.3.1 
To the second paragraph the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification: 
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 N/A 
15.1.1 
Mains socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as fas as a Applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2.5 A 250 V two-pole socket-outlets for 
electronic apparatus shall comply with the 
enclosed Standard Sheet I. 
 
Justification: 
Act of 24 May 1929 relating to supervision of 
electrical installation (TEA 1929/FEL 1998). 
 N/A 
 
Page 40 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
J.2 
After Table J.1 the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 N/A 
 
Page 41 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
Annex B 
Replace NOTE 1 by 
In the CENELEC countries listed in IEC 62151, special 
national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151). 
Subclause 4.1.1 (Corrigendum 2): 
Add after the first paragraph: 
NOTE – In Norway, CLASS I equipment which is 
intended for connection to the building installation via a 
non-industrial plug or a non-industrial appliance 
coupler, or both and in addition is intended for 
connection to other equipment or a network shall, if 
safety relies on connection to protective earth or if 
surge suppressors are connected between the network 
terminals and ACCESSIBLE parts, have a marking 
stating that the equipment must be connected to an 
earthed mains socket –outlet. 
The marking text shall be as follows: 
 
”Apparatet skal tilkoples jordet stikkontakt” 
 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there are 
additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text is 
identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation forming 
part of a component, it shall at least consist of either 
- two layers of thin sheet material, each of which shall 
pass the electric strength test below, or 
- one layer having a distance through insulation of at 
least 0,4 mm, which shall pass the electric strength test 
below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no distance 
through insulation 
requirement for the insulation consisting of an 
insulating compound completely filling the casing, so 
that CLEARANCES 
and CREEPAGE DISTANCES do not exist, if the 
component passes the electric strength test in the 
accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 with an 
electric strength test of 10.3 using the test voltage of 
1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric strength during 
manufacturing, using a test voltage of 1,5 kV (for 
performance of the test see N.2.1). 
It is permitted to bridge this insulation with a capacitor 
complying with IEC 60384-14:1993, subclass Y2. 
 N/A 
 
Page 42 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
Annex B 
Cont. 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following 
conditions: 
- the insulation requirements are satisfied by having a 
capacitor classified Y3 as defined by IEC 60384-14, 
which in addition to the Y3 testing, is tested with an 
Impulse test of 2.5kV defined in IEC 62151, subclause 
6.2.1; 
- the additional testing shall be performed on all the test 
specimens as described in IEC 60384-14; 
- the Impulse test of 2.5kV is to be performed before 
the Endurance Test in IEC 60384-14 in the sequence 
of tests as described in IEC 60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE – In Norway, exclusions are applicable for 
equipment which is intended for connection to the 
building installation 
wiring using screw terminals or other reliable means, 
and for equipment which is intended for connection to 
the building installation wiring via an industrial plug and 
socket –outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 N/A 
 