Page 43 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
 
National differences  Sweden 
IEC 60065:2001 
(See also Group Differences)            
                                                                
CB Bulletin 110A / SE  06  I
 
14 
Switches containing mercury such as thermostats, 
relays and level controllers are not allowed. 
 
 
 
Page 44 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
Annex B 
Replace NOTE 1 by 
In the y CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151). 
Subclause 4.1.1 (Corrigendum 2): 
Add after the first paragraph: 
NOTE – In Sweden, CLASS I equipment which is 
intended for connection to the building installation via a 
non-industrial plug or a non-industrial appliance 
coupler, or both and in addition is intended for 
connection to other equipment or a network shall, if 
safety relies on connection to protective earth or if 
surge suppressors are connected between the network 
terminals and ACCESSIBLE parts, have a marking 
stating that the equipment must be connected to an 
earthed mains socket –outlet. 
The marking text shall be as follows: 
 
”Apparaten skall anslutas till jordat uttag” 
 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there are 
additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text is 
identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation forming 
part of a component, it shall at least consist of either 
- two layers of thin sheet material, each of which shall 
pass the electric strength test below, or 
- one layer having a distance through insulation of at 
least 0.4 mm, which shall pass the electric strength test 
below. 
If this insulation forms part of a semiconductor  
component (e.g. an optocoupler), there is no distance 
through insulation requirement for the insulation 
consisting of an insulating compound completely filling 
the casing, so that CLEARANCES and CREEPAGE 
DISTANCES do not exist, if the component passes the 
electric strength test in the accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 with an 
electric strength test of 10.3 using the test voltage of 
1.5 kV multiplied by 1,6  and 
- is subject to routine testing for electric strength during 
manufacturing, using a test voltage of 1.5 kV (for 
performance of the test see N.2.1). 
 N/A 
 
 
Page 45 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
Annex B 
Cont.
 
It is permitted to bridge this insulation with a capacitor 
complying with IEC 60384-14:1993, subclass Y2.  A 
capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the following 
conditions: 
- the insulation requirements are satisfied by having a 
capacitor classified Y3 as defined by IEC 60384-14, 
which in addition to the Y3 testing, is tested with an 
Impulse test of 2.5kV defined in IEC 62151, subclause 
6.2.1;- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-14; 
- the Impulse test of 2.5kV is to be performed before 
the Endurance Test in IEC 60384-14 in the sequence 
of tests as described in IEC 60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals or 
other reliable means, and for equipment which is 
intended for connection to the building installation 
wiring via an industrial plug and socket -outlet or an 
appliance coupler, or both, complying with IEC 60309 
or with a comparable national standard.
 
 N/A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page 46 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
 
 
National differences KOREA 
IEC 60065 
 
CB Bulletin KR 2005 I
 
 
5.101 Addition 
Other marking; 
Wording “            “ ( See the CB Bulletine) or an 
information regulated in IEC Publication 60417 
giving high voltage warning to layman shall be 
marked, if an apparatus contains a part more 
than 600 volts. 
 
N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirements (KSC 8300 and 8305). 
 P 
31 
Radio frequency Interference 
The apparatus shall comply with the relevant 
CISPR requirements. (EMC=EMI + EMS) 
Not checked 
N/A 
 