Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N/A
15.3.5
Terminals allow connection of appropriate
cross-sectional area of conductors, for the rated
current of the equipment
cross-sectional area of conductors, for the rated
current of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by
table 16
table 16
N/A
15.3.7
Terminals clamp conductors between metal
and have adequate pressure
and have adequate pressure
N/A
Terminals designed to avoid conductor slipping
out when tightened or loosened
out when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions
of mains plugs
of mains plugs
N/A
15.4.3
Device has adequate mechanical strength
(tests a,b,c)
(tests a,b,c)
N/A
Page 20 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
16 EXTERNAL
FLEXIBLE
CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ...................................................... :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ...................................................... :
PVC P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of
the equipment
sectional area for rated current consumption of
the equipment
2 x 0.75mm
2
P
16.3
a) Flexible cords not complying with 16.1, used
for interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate
dielectric strength
for interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate
dielectric strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2
of IEC 60227-2)
withstand bending and mechanical stress (3.2
of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional
areas to avoid temperature rise under normal
and fault conditions
equipment have adequate cross-sectional
areas to avoid temperature rise under normal
and fault conditions
N/A
16.5
Adequate strain relief on external flexible cords Strain relief bushing under
compression
P
Not possible to push cord back into equipment
P
Strain relief device unlikely to damage flexible
cord
cord
P
For mains cords of Class I equipment,
hazardous live conductors become taut before
earth conductor
hazardous live conductors become taut before
earth conductor
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or
movement in use
damage to the cord during assembly or
movement in use
P
16.7
Transportable musical instruments and
amplifiers fitted with detachable cord set with
appliance inlet to IEC 60320-1
amplifiers fitted with detachable cord set with
appliance inlet to IEC 60320-1
N/A
Transportable musical instruments and
amplifiers fitted with detachable cord sets or
with means of stowage to protect the cord
amplifiers fitted with detachable cord sets or
with means of stowage to protect the cord
N/A
Page 21 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
- screws into metal: 5 times
N/A
- screws into non-metallic material: 10 times
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
P
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times
its diameter
replaced by a screw whose length is 10 times
its diameter
P
17.4
No loosening of conductive parts carrying a
current > 0,2 A
current > 0,2 A
N/A
17.5
Contact pressure not transmitted through
plastic other than ceramic for connections
carrying a current > 0,2 A
plastic other than ceramic for connections
carrying a current > 0,2 A
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals
not consolidated by solder
carrying a current > 0,2 A with screw terminals
not consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
2N P
Page 22 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
N/A
Picture tube separately approved to 18.1 .........
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used
with protective screen
with protective screen
N/A
18.2
Intrinsically protected tubes: tests on
12 samples
12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test
(steel ball): 6
(steel ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ............ : >13 kg
P
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
Apparatus mass > 25 kg or height > 1 m or
supplied with cart or stand
supplied with cart or stand
N/A
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces with an area exceeding 0,1 m²
or maximum dimension > 450 mm, pass the
test of 19.5.1
or maximum dimension > 450 mm, pass the
test of 19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A