Harman Kardon HKTS 7 (serv.man3) EMC - CB Certificate ▷ View online

 
Page 23 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
20 RESISTANCE 
TO 
FIRE 
 
20.1 
Electrical components and mechanical parts 
 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined 
in 20.1 
Close-end connector 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4 
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. 
meets V-1 or better to IEC60707, unless used 
in a fire enclosure 
PCB P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
>400 V (peak) a.c. or d.c. meets V-0 to 
IEC 60707 
 N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source 
than the distances in Table 21 comply with the 
relevant flammability category in Table 21 
Bobbin; Plastic enclosure; 
Fuse holder; Mains switch; Switch and 
Fuse holder tubing; 
Sec. connector P103 (see list of 
critical. components and materials) 
 
Components and parts as above but shielded 
from a potential ignition source, with the barrier 
area in accordance with Table 21 and fig. 13 
 N/A 
 
Apparatus with voltages > 4 kV under normal 
conditions, and distances to enclosure exceed 
those specified by Table 21, HB40 min 
enclosure 
 N/A 
20.2 
Fire enclosure 
 
20.2.1 
Potential ignition sources with open circuit 
voltage > 4 kV (peak) a.c. or d.c. contained in a 
fire enclosure to V-1 
 N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
 
 
 
Page 24 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH PROTECTION 
AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does 
not apply 
 N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N/A 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
N/A 
 
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1 
 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 
3.5.4 modified to 2.4.10 of this standard 
 N/A 
 
Complies with IEC 62151 clause 4 but with 
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance 
with annex B of this standard 
 N/A 
 
Complies with IEC 62151 clause 5 but with 
5.3.1 modified in accordance with annex B of 
this standard 
 N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
 
 
Page 25 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
7.1 TABLE: 
temperature 
rise measurements: Conditions 
 
Power consumption in the OFF/Stand-by mode   
 
 
of the functional switch (W) ................................: 0W in OFF mode 
— 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
253 
50 
0.45 
77 
9.1 
21 
1/8 of max non-clipping output 
power (pink noise). Input signal 
connected to ’Line in L/R’ 
 
 
Loudspeaker impedance (Ω) .............................: 4 
— 
 
Several loudspeaker systems 
Built-in speaker 
 
 
Marking of loudspeaker terminals 
High Level  in/out 
 
Temperature Rise dT of Part
 
dT (K) 
Limit dT (K) 
Test Condition No. 
No 1 
No ___ 
No ___ 
 
Core of transformer                                             
51 
 
 
Transformer support (rubber)                             
51 
 
 
Supply cords (Not under mechanical stress) 
27 
 
 
60   
Mains switch 
26 
 
 
60  
Mains fuse 
26 
 
 
60  
Enclosure (wood) 
24 
 
 
60  
PCB 63 
 
 
85  
Buttons (plastic) 
18 
 
 
50 
Heat sink, on rear panel 
40 
 
 
40 
Rear panel, near knobs 
38 
 
 
40  
Knobs (plastic) 
18 
 
 
50  
 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ............................. :
21 
— 
— 
— 
— 
Ambient temperature t2 (
o
C) ............................. :
22 
— 
— 
— 
— 
Temperature rise dT of winding: 
(
) (
)
1
2
1
5
,
234
1
1
2
t
t
t
R
-R
R
dT
+
×
=


 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT 
(K) 
Insulation 
class 
Prim. winding 
9.267 
11.498 
61 
85  
Sec. winding red-red 
1.252 1.528  55  85  E 
Sec. winding yellow-yellow 
0.701 0.855  55  85  E 
 
Page 26 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
9.1 
Shock Hazard  
 
Under normal operating conditions: > 35Vpk ac / 60V dc 
 
Notes:  Reference Annex D  
 
CLASS I: (single phase) 
 
AC DC 
 
 
 
U1: - 
Vpk 
mA 
rms
 
U1: 
V  
- mA
 
 
 
 
 
 
U2: - 
Vpk 
 
- mA rms
 
 
 
 
 
CLASS II: (single phase)  
 
AC DC 
 
 
 
U1: 0.05V 
pk 
 
- mA rms
 
U1: - 
 
- mA 
 
 
 
 
 
U2: 0.01V 
pk 
 
- mA rms
 
 
- mA
 
 
10.3 
TABLE: Insulation Resistance Measurements 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ)
Between the poles of the circuit directly connected to 
the supply mains. 
>10 Min. 
Reinforced insulation. 
>10 Min. 
 
 
10.3 
TABLE: Electric Strength Measurements 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
Page of 59