Harman Kardon HKTS 7 (serv.man3) EMC - CB Certificate ▷ View online
Page 15 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Coil formers and partition walls ≥ 0,4 mm
1.3mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
Prim.-iron core: 7.0mm
P
Coil formers and partition walls = 0,4 mm
1.3mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
N/A
Winding wires connected to protective earth
have adequate current-carrying capacity
have adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested
as part of the submission
as part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances
meet requirement of clause 13 for the voltage
across the device when opened
meet requirement of clause 13 for the voltage
across the device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the
submission
submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder . T1.25AL 250V
P
14.5.2.3
Not possible to connect fuses in parallel .......... : No
P
Page 16 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
14.5.2.4
Not possible to touch hazardous live parts
when replacing fuse-links without the use of a
tool ..................................................................... :
when replacing fuse-links without the use of a
tool ..................................................................... :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush............................... :
Mains switch, (MOMS)
16(4) 8/128A
250VAC
23A (calculated)
P
14.6.1 b)
Tested in the apparatus:
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has
making/breaking action independent of speed
of actuation
61058-1 subclause 13.1 and has
making/breaking action independent of speed
of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate
dielectric strength
dielectric strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
Page 17 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric
strength
test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation
of flammable gases
of flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse
currents within the manufacturers limits
currents within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
14.12
Surge suppression varistors
Comply with IEC 61051-2
N/A
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
Page 18 of 46
Report Ref No.: 615278
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar
devices not compatible with household mains
socket-outlets
devices not compatible with household mains
socket-outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class I
equipment reliably connected to earth terminal,
within equipment
equipment reliably connected to earth terminal,
within equipment
N/A
Class I supply equipment with non-hazardous
live output voltage: output circuit not connected
to earth
live output voltage: output circuit not connected
to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Earthing connection of parts removable by
hand.
hand.
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ............. : N/A
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of
permanent wiring
permanent wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
Not soldered to conductors of a printed circuit
board
board
P
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
Connected by Close-end connector to
internal wire and bended around pin
before soldering.
internal wire and bended around pin
before soldering.
P