DOWNLOAD Harman Kardon HKTS 7 (serv.man3) Service Manual ↓ Size: 1.9 MB | Pages: 59 in PDF or view online for FREE

Model
HKTS 7 (serv.man3)
Pages
59
Size
1.9 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-7-sm3.pdf
Date

Harman Kardon HKTS 7 (serv.man3) EMC - CB Certificate ▷ View online

 
Page 11 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. 
after surge test for basic and 4 MΩ min. for 
reinforced insulation .......................................... :
No antenna terminal 
N/A 
10.2 
Humidity treatment 48 h or 120 h  ..................... : 48 h  
10.3 
Insulation resistance and dielectric strength 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
 
No flaming more than 10s 
 
 
Soldered terminations not used as protective 
mechanism 
 N/A 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards 
(PCB) exceeding the limits of table 3 by max. 
100 K for max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards 
(PCB) to 20.1.3, exceeding the limits of table 3 
by not more than 100 K for an area not greater 
than 2 cm² 
 N/A 
 
b) Temperature rise of printed circuit boards 
(PCB) to 20.1.3 up to 300 K for an area not 
greater than 2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
At Uin=198V, voltage across 
interruption <50Vp  (see table 11) 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 Table 3 e) "Other Parts" 
 P 
 
 
Page 12 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
12 MECHANICAL 
STRENGTH 
12.1.1 
Bump test where mass >7 kg 
 
12.1.2 
Vibration test (portable, metal, musical amps) 
No connection or part which might 
impair safety can become loose. 
12.1.3 
Impact hammer test  
 
 
Steel ball test (for non-ventilated solid areas) 
3.5J   top, sides, back , front 
12.1.4 
Drop test for portable apparatus where mass ≤ 
7 kg 
 N/A 
12.1.5 
Thermoplastic enclosures stress relief test 
 
N/A 
12.2 
Fixing of knobs, push buttons, keys and levers   
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
Page 13 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
Prim – sec. >10mm 
Prim – acc. metal parts : >10mm 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
See TABLE 13 
13.3 
Clearances 
 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable,  
table 9 
 P 
13.3.3 
Circuits not conductively connected to the 
mains comply with table 10 
Circuits not conductively connected to 
the mains cannot cause any shock 
hazard. 
N/A 
13.3.4 
Measurement of transient voltages 
 
13.4 
Creepage distances 
 
 
 
Creepage distances greater than table 11 
minima 
 P 
13.5 
Printed boards 
 
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of 
which may be conductively connected to the 
mains, as in fig. 10 
 N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply 
with 13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed 
parts: not conductively connected to the mains: 
clearances and creepage distances as in 
table 12 
 N/A 
13.8 Parts 
filled with insulating compound, meeting 
the requirements of 8.8 
 N/A 
 
 
Page 14 of 46 
Report Ref No.: 615278 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
14 COMPONENTS 
 
14.1 
Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
Resistors separately approved ......................... :  
N/A 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
 
N/A 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition ................................................................ :
 N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition ................................................................ :
  
N/A 
14.2.3 
Capacitors operating at mains frequency but 
not connected to the mains: tests for X2 .......... :
 N/A 
14.2.5     
a) 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B 
or better  ................................................................
 N/A 
b) 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source 
than table 5 permits: compliance with 
IEC 60 384-1, 4.38 category B or better ........... :
 N/A 
 
Shielded by a barrier per Table 21 .................... :  
N/A 
14.3 
Inductors and windings 
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ......................... :
Transtec TT0869803320 alt. 
TT0869803320-E 
 
Transformers and inductors separately 
approved ............................................................ :
No 
N/A 
14.3.2 
General 
 
 
14.3.3 
Constructional requirements (complete 
appended tables or include manufacturers 
constructional insulation descriptions) 
 P 
14.3.3.1 
Clearances and creepage distances comply 
with clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Prim.-sec: 8.1mm 
 
Page of 59