Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
Not hand-held equipment.
N/A
1.6.4
Neutral conductor
N/A
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
See below.
P
1.7.1.1
Power rating marking
See below
P
Multiple mains supply connections..........................: Not directly connected to the
mains.
N/A
Rated voltage(s) or voltage range(s) (V) ...............: 24V
P
Symbol for nature of supply, for d.c. only ...............: IEC 60417-5031 used.
See above.
P
Rated frequency or rated frequency range (Hz) ....: DC source.
N/A
Rated current (mA or A) ........................................: 2.3A
P
1.7.1.2
Identification markings
See below.
P
Manufacturer’s name or trade-mark or identification
mark .......................................................................:
mark .......................................................................:
P
Model identification or type reference ....................: Go + Play micro
P
Symbol for Class II equipment only .......................: Class III equipment.
N/A
Other markings and symbols .................................: Other markings and symbols
do not give rise to
misunderstanding.
misunderstanding.
P
1.7.2
Safety instructions and marking
Provided with marking
regarding use of specified
power supply, refer to copy of
marking plate.
regarding use of specified
power supply, refer to copy of
marking plate.
P
1.7.2.1
General
Instructions are available.
P
1.7.2.2
Disconnect devices
Not directly connected to the
mains.
mains.
N/A
1.7.2.3
Overcurrent protective device
Not directly connected to the
mains.
mains.
N/A
1.7.2.4
IT power distribution systems
Not directly connected to the
mains.
mains.
N/A
1.7.2.5
Operator access with a tool
N/A
1.2.7.6
Ozone
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ....................................:
No supply voltage adjustment.
N/A
Page 9 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
Methods and means of adjustment; reference to
installation instructions ..........................................:
installation instructions ..........................................:
N/A
1.7.5
Power outlets on the equipment ...........................:
No standard power outlet.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) ..........................:
characteristics, cross-reference) ..........................:
No fuses.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ...........:
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
See below.
P
1.7.8.1
Identification, location and marking ......................:
Indication located on stand-by
switch.
switch.
P
1.7.8.2
Colours ................................................................:
For functional control only.
P
1.7.8.3
Symbols according to IEC 60417 .........................:
Push-push switch used.
(IEC 60417-5009) for the
stand-by condition.
P
1.7.8.4
Markings using figures ........................................:
Not used.
N/A
1.7.9
Isolation of multiple power sources .....................:
Class III equipment.
N/A
1.7.10
Thermostats and other regulating devices ..........:
Not used.
N/A
1.7.11
Durability
The label was rubbed with
cloth soaked with water for
15s and then again for 15s
with the cloth soaked with
petroleum spirit.
cloth soaked with water for
15s and then again for 15s
with the cloth soaked with
petroleum spirit.
After this test there was no
damage to the label. The
marking on the label did not
fade. There was neither
curling nor lifting of the label
edge.
damage to the label. The
marking on the label did not
fade. There was neither
curling nor lifting of the label
edge.
P
1.7.12
Removable parts
Not put on removable parts.
P
1.7.13
Replaceable batteries ...........................................:
8 C size batteries used. The
battery compartment prevents
from replacing wrong type
batteries.
battery compartment prevents
from replacing wrong type
batteries.
P
Language(s) ..........................................................:
1.7.14
Equipment for restricted access locations .............:
Not intended for installation in
restricted access locations.
restricted access locations.
N/A
2
PROTECTION FROM HAZARDS
Supply from power adaptor that is considered to carry SELV at below 240VA only. No
risk of electrical shock or energy hazards.
Supply from power adaptor that is considered to carry SELV at below 240VA only. No
risk of electrical shock or energy hazards.
P
Page 10 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
Only SELV inside the unit. No
electrical shock or energy
hazards.
electrical shock or energy
hazards.
P
2.1.1.1
Access to energized parts
Compliance of protection
against contact with
hazardous energized parts
checked:
against contact with
hazardous energized parts
checked:
P
Test by inspection .................................................:
Complied.
P
Test with test finger (Figure 2A) ...........................:
P
Test with test pin (Figure 2B) ................................:
N/A
Test with test probe (Figure 2C) ...........................:
N/A
2.1.1.2
Battery compartments
No TNV circuits.
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
(see appended tables 2.10.2
and 2.10.5)
and 2.10.5)
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ......................................................: No energy hazard in operator
access area.
P
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
Measured voltage (V); time-constant (s) ................:
2.1.1.8
Energy hazards – d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains supply ...:
N/A
b) Internal battery connected to the d.c. mains
supply .....................................................................:
supply .....................................................................:
N/A
2.1.1.9
Audio amplifiers .....................................................: No parts of audio amplifier are
accessible for the users.
P
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
The unit not intended to be
used in restricted locations.
used in restricted locations.
N/A
2.2
SELV circuits
Supply from power adaptor that is considered to carry SELV at below 240VA only. No
risk of electrical shock or energy hazards.
Supply from power adaptor that is considered to carry SELV at below 240VA only. No
risk of electrical shock or energy hazards.
P
2.2.1
General requirements
See below.
P
2.2.2
Voltages under normal conditions (V) ...................:
42.4V peak or 60V d.c. are
not exceeded in SELV circuit
under normal operation.
not exceeded in SELV circuit
under normal operation.
See appended table 2.2.2.
P
Page 11 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
2.2.3
Voltages under fault conditions (V) ........................:
Single fault did not cause
excessive voltage in
accessible SELV circuits.
Limits of 71V peak and 120V
d.c. were not exceeded within
0.2s and limits 42.4V peak
and 60V d.c. were not
exceeded for longer than 0.2s.
excessive voltage in
accessible SELV circuits.
Limits of 71V peak and 120V
d.c. were not exceeded within
0.2s and limits 42.4V peak
and 60V d.c. were not
exceeded for longer than 0.2s.
P
2.2.4
Connection of SELV circuits to other circuits .......:
No direct connection between
SELV and any primary circuits
SELV and any primary circuits
P
2.3
TNV circuits
N/A
2.3.1
Limits
N/A
Type of TNV circuits ...............................................:
2.3.2
Separation from other circuits and from accessible
parts
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ..........................:
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed................................................:
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation employed................................................:
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
N/A
2.4.1
General requirements
N/A
2.4.2
Limit values
N/A
Frequency (Hz) .......................................................:
Measured current (mA)...........................................:
Measured voltage (V) .............................................:
Measured circuit capacitance (nF or µF) ................:
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5
Limited power sources
(see appended table 2.5)
N/A
a) Inherently limited output
N/A
b) Impedance limited output
N/A