DOWNLOAD Harman Kardon GO PLAY MICRO (serv.man2) Service Manual ↓ Size: 1.93 MB | Pages: 70 in PDF or view online for FREE

Model
GO PLAY MICRO (serv.man2)
Pages
70
Size
1.93 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-play-micro-sm2.pdf
Date

Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate ▷ View online

 
Page 20 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
4.3.8 
Batteries 
(see appended tables 4.3.8) 
 
- Overcharging of a rechargeable battery 
Non-rechargeable batteries 
used.  
N/A 
 
- Unintentional charging of a non-rechargeable 
battery 
Tested and complied.  
 
- Reverse charging of a rechargeable battery 
 
N/A 
 
- Excessive discharging rate for any battery 
Tested and complied.  
4.3.9 
Oil and grease 
 
N/A 
4.3.10 
Dust, powders, liquids and gases 
No dangerous concentration, 
vaporization, leakage, spillage 
or corrosion likely. 
4.3.11 
Containers for liquids or gases 
 
N/A 
4.3.12 
Flammable liquids .................................................: 
 
N/A 
 
Quantity of liquid (l)  ...............................................: 
 
N/A 
 
Flash point (
°
C) .....................................................: 
 
N/A 
4.3.13 
Radiation 
See below. 
4.3.13.1 
General 
See below. 
4.3.13.2 
Ionizing radiation  
 
N/A 
 
Measured radiation (pA/kg)  ............................... : 
 
N/A 
 
Measured high-voltage (kV) ............................... : 
 
N/A 
 
 
Measured focus voltage (kV) ............................. : 
 
N/A 
 
CRT markings .................................................... : 
 
N/A 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
 
N/A 
 
Part, property, retention after test, flammability 
classification  .........................................................: 
 
N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation .......: 
 
N/A 
4.3.13.5 
Lasers (including laser diodes) and LEDs 
Indicating lights used only. 
4.3.13.5.1  Lasers (including laser laser diodes) 
 
N/A 
 
Laser class ............................................................: 
 
 
4.3.13.5.2  Light emitting diodes (LEDs) 
Far lower than AEL of class 1.  
4.3.13.6 
Other types  ...........................................................: 
 
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 
General 
 
N/A 
4.4.2 
Protection in operator access areas  .................... : 
 
N/A 
 
Household and home/office document/media 
shredders 
(see Annex EE) 
N/A 
 
Page 21 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
4.4.3 
Protection in restricted access locations  ............. : 
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
4.4.5 
Protection against moving fan blades 
 
N/A 
4.4.5.1 
General 
 
N/A 
 
Not considered to cause pain or injury. a)………….:   
N/A 
 
Is considered to cause pain, not injury. b) …………:   
N/A 
 
Considered to cause injury.                   c) …………:    
N/A 
4.4.5.2 
Protection for users 
 
N/A 
 
Use of symbol or warning ……………………………:   
N/A 
4.4.5.3 
Protection for service persons 
 
N/A 
 
Use of symbol or warning ……………………………:   
N/A 
 
 
 
 
4.5 
Thermal requirements 
4.5.1 
General 
4.5.2 
Temperature tests 
No exceeding temperature. 
 
Normal load condition per Annex L ...................... : 
 
 
4.5.3 
Temperature limits for materials 
(see appended table 4.5) 
4.5.4 
Touch temperature limits 
(see appended table 4.5) 
4.5.5 
Resistance to abnormal heat  ............................... : 
 
N/A 
 
 
 
 
4.6 
Openings in enclosures 
4.6.1 
Top and side openings 
No openings.  
 
Dimensions (mm)  ................................................ : 
 
 
4.6.2 
Bottoms of fire enclosures 
No openings.  
 
Construction of the bottomm, dimensions (mm)  . : 
 
 
4.6.3 
Doors or covers in fire enclosures 
 
N/A 
4.6.4 
Openings in transportable equipment 
 
N/A 
4.6.4.1 
Constructional design measures 
 
N/A 
 
Dimensions (mm)  ................................................ : 
 
 
4.6.4.2 
Evaluation measures for larger openings 
 
N/A 
4.6.4.3 
Use of metallized parts 
 
N/A 
4.6.5 
Adhesives for constructional purposes 
 
N/A 
 
Conditioning temperature (
°
C), time (weeks) ....... : 
 
 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame 
See below.  
 
Page 22 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
 
Method 1, selection and application of components 
wiring and materials 
(see appended table 4.7) 
 
Method 2, application of all of simulated fault 
condition tests 
(see appended table 5.3) 
4.7.2 
Conditions for a fire enclosure 
See below.  
4.7.2.1 
Parts requiring a fire enclosure 
See below.  
N/A 
4.7.2.2 
Parts not requiring a fire enclosure 
Following parts do not require 
a fire enclosure: 
 
Connectors in secondary 
circuits supplied by limited 
power source. 
 
Other components in 
secondary circuits supplied 
by limited power source 
and mounted on V-1 
material. 
4.7.3 
Materials 
 
4.7.3.1 
General 
Those components are 
mounted on V-1 material and 
separated from material of a 
class lower than V-1 by at 
least 13 mm of air. 
4.7.3.2 
Materials for fire enclosures 
 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
 
N/A 
4.7.3.4 
Materials for components and other parts inside fire 
enclosures 
 
N/A 
4.7.3.5 
Materials for air filter assemblies 
 
N/A 
4.7.3.6 
Materials used in high-voltage components 
 
N/A 
 
 
 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
Class III equipment.  
N/A 
5.1.1 
General 
 
N/A 
5.1.2 
Configuration of equipment under test (EUT) 
 
N/A 
5.1.2.1 
Single connection to an a.c. mains supply 
 
N/A 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 
N/A 
5.1.2.3 
Simultaneous multiple connections to an a.c. mains 
supply 
 
N/A 
5.1.3 
Test circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
 
Page 23 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
5.1.5 
Test procedure 
 
N/A 
5.1.6 
Test measurements 
 
N/A 
 
Supply voltage (V) .................................................: 
 
 
 
Measured touch current (mA) ...............................: 
 
 
 
Max. allowed touch current (mA)  ..........................: 
 
 
 
Measured protective conductor current (mA)  .......: 
 
 
 
Max. allowed protective conductor current (mA) ...: 
 
 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
N/A 
5.1.7.1 
General  .................................................................: 
 
N/A 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
N/A 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable distribution 
system 
 
N/A 
 
Supply voltage (V) .................................................: 
 
 
 
Measured touch current (mA) ...............................: 
 
 
 
Max. allowed touch current (mA)  ..........................: 
 
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks 
 
N/A 
 
a) EUT with earthed telecommunication ports ......: 
 
N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 
N/A 
 
 
 
 
5.2 
Electric strength 
Class III equipment 
N/A 
5.2.1 
General 
(see appended table 5.2) 
N/A 
5.2.2 
Test procedure  
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal operation  (see appended table 5.3)  
5.3.2 
Motors 
(see appended Annex B)  
N/A 
5.3.3 
Transformers 
(see appended Annex C)  
N/A 
5.3.4 
Functional insulation ..............................................: 
Functional insulation complied 
with the requirements c). 
5.3.5 
Electromechanical components 
 
N/A 
5.3.6 
Audio amplifiers in ITE ..........................................: 
(see appended table 5.3) 
Page of 70
Display