Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate ▷ View online
Page 16 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
- Basic insulation not under stress .........................:
N/A
- Supplemetary, reinforced insulation ....................:
N/A
2.10.6
Construction of printed boards
N/A
2.10.6.1
Uncoated printed boards
(see appended table 2.10.3
and 2.10.4)
and 2.10.4)
N/A
2.10.6.2
Coated printed boards
(see appended table 2.10.3
and 2.10.4)
and 2.10.4)
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
surface of a printed board
(see appended table 2.10.3
and 2.10.4)
and 2.10.4)
N/A
2.10.6.4
Insulation between conductors on different layers of
a printed board
a printed board
N/A
Distance through insulation
(see appended table 2.10.5)
N/A
Number of insulation layers (pcs) ...........................:
N/A
2.10.7
Component external terminations
(see appended table 2.10.3
and 2.10.4)
and 2.10.4)
N/A
2.10.8
Tests on coated printed boards and coated
components
components
N/A
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
(see appended table 5.2)
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
See below.
P
3.1.1
Current rating and overcurrent protection
The cross-sectional area of the
wires is adequate and
complied with the tests of 4.5.2
and 4.5.3.
wires is adequate and
complied with the tests of 4.5.2
and 4.5.3.
P
3.1.2
Protection against mechanical damage
The wireways (including
holes) are smooth and free
from sharp edges.
holes) are smooth and free
from sharp edges.
P
3.1.3
Securing of internal wiring
No excessive strain on wire
and on terminal connections,
loosing of terminal
connections and damage of
conductor insulation.
and on terminal connections,
loosing of terminal
connections and damage of
conductor insulation.
P
Page 17 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
3.1.4
Insulation of conductors
The insulation of the individual
conductors is suitable for the
application and the working
voltage. For the insulation
material see 3.1.1.
conductors is suitable for the
application and the working
voltage. For the insulation
material see 3.1.1.
P
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
N/A
10 N pull test
N/A
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
N/A
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
conduits (mm) ....................................................... :
3.2.4
Appliance inlets
N/A
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type ...................................................................... :
Rated current (A), cross-sectional area (mm
2
),
AWG ..................................................................... :
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................... :
Longitudinal displacement (mm) ........................... :
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
Radius of curvature of cord (mm).......................... :
3.2.9
Supply wiring space
N/A
Page 18 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
)............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ..................................................................... :
(mm) ..................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
N/A
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
See below.
P
3.5.2
Types of interconnection circuits .......................... :
SELV circuit.
P
3.5.3
ELV circuits as interconnection circuits
N/A
3.5.4
Data ports for additional equipment
No power on data ports.
P
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N/A
Angle of 10
°
Mass less than 7 kg ( 3.9 kg )
N/A
Page 19 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
Test force (N) .........................................................: Not a floor-standing unit.
N/A
4.2
Mechanical strength
N/A
4.2.1
General
Class III equipment.
N/A
Rack-mounted equipment.
(see Annex DD)
N/A
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
N/A
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test; height (mm) ...........................................:
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................: (see separate test report or
attached certificate)
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) .......:
N/A
4.2.11
Rotating solid media
N/A
Test to cover on the door…………………………….:
N/A
4.3
Design and construction
Class III equipment
Class III equipment
P
4.3.1
Edges and corners
All edges or corners
accessible to operator are
rounded and smoothed.
accessible to operator are
rounded and smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
N/A
4.3.3
Adjustable controls
N/A
4.3.4
Securing of parts
No loosen.
P
4.3.5
Connection by plugs and sockets
No misconnection likely.
P
4.3.6
Direct plug-in equipment
N/A
Torque ..................................................................:
Compliance with the relevant mains plug standard
...............................................................................:
N/A
4.3.7
Heating elements in earthed equipment
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.