Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate ▷ View online

 
Page 12 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
N/A 
 
d) Overcurrent protective device limited output 
 
N/A 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA)......................................: 
 
 
 
Current rating of overcurrent protective device (A) .:   
 
 
Use of integrated circuit (IC) current limiters 
(See Annex CC) 
 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
 
N/A 
2.6.2 
Functional earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .......................................................................: 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG .......................................................................: 
 
 
 
Protective current rating (A), cross-sectional area 
(mm
2
), AWG ...........................................................: 
 
N/A 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (
), voltage drop (V), test 
current (A), duration (min) ......................................: 
 
N/A 
2.6.3.5 
Colour of insulation .................................................: 
 
N/A 
2.6.4 
Terminals 
 
N/A 
2.6.4.1 
General 
 
N/A 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 
 
Rated current (A), type, nominal thread diameter 
(mm) .......................................................................: 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors and 
protective bonding conductors 
 
N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 
2.6.5.4 
Parts that can be removed by an operator 
 
N/A 
2.6.5.5 
Parts removed during servicing 
 
N/A 
 
Page 13 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
2.6.5.6 
Corrosion resistance 
 
N/A 
2.6.5.7 
Screws for protective bonding 
 
N/A 
2.6.5.8 
Reliance on telecommunication network or cable 
distribution system 
 
N/A 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
N/A 
2.7.1 
Basic requirements 
 
N/A 
 
Instructions when protection relies on building 
installation 
 
N/A 
2.7.2 
Faults not simulated in 5.3.7 
 
N/A 
2.7.3 
Short-circuit backup protection 
 
N/A 
2.7.4 
Number and location of protective devices ........... : 
 
N/A 
2.7.5 
Protection by several devices 
 
N/A 
2.7.6 
Warning to service personnel ................................ : 
 
N/A 
 
2.8 
Safety interlocks 
N/A 
2.8.1 
General principles 
 
N/A 
2.8.2 
Protection requirements 
 
N/A 
2.8.3 
Inadvertent reactivation 
 
N/A 
2.8.4 
Fail-safe operation 
 
N/A 
 
Protection against extreme hazard 
 
N/A 
2.8.5 
Moving parts 
 
N/A 
2.8.6 
Overriding  
 
N/A 
2.8.7 
Switches, relays and their related circuits 
 
N/A 
2.8.7.1 
Separation distances for contact gaps and their 
related circuits (mm)  ..............................................: 
 
N/A 
2.8.7.2 
Overload test 
 
N/A 
2.8.7.3 
Endurance test 
 
N/A 
2.8.7.4 
Electric strength test  
(see appended table 5.2)   
N/A 
2.8.8 
Mechanical actuators 
 
N/A 
 
2.9 
Electrical insulation 
The unit is supplied from an approved power supply that provides SELV. Only SELV 
and limited current circuit inside the unit.
 
2.9.1 
Properties of insulating materials 
 
2.9.2 
Humidity conditioning 
Natural rubber, asbestos or 
hygroscopic materials are not 
used. 
 
Relative humidity (%), temperature (°C) .......... ..... : 
 
 
 
Page 14 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
2.9.3 
Grade of insulation 
Functional insulation. 
2.9.4 
Separation from hazardous voltages 
 
N/A 
 
Method(s) used ..................................................... : 
 
 
 
2.10 
Clearances, creepage distances and distances through insulation 
2.10.1 
General  
Only SELV inside the unit. 
2.10.1.1 
Frequency ..............................................................:   
N/A 
2.10.1.2 
Pollution degrees  ...................................................:  2 
2.10.1.3 
Reduced values for functional insualtion 
See 5.3.4. 
2.10.1.4 
Intervening unconnected conductive parts 
 
N/A 
2.10.1.5 
Insulation with varying dimensions 
 
N/A 
2.10.1.6 
Special separation requirements 
 
N/A 
2.10.1.7 
Insulation in circuits generating starting pulses 
 
N/A 
2.10.2 
Determination of working voltage 
 
N/A 
2.10.2.1 
General 
 
N/A 
2.10.2.2 
RMS working voltage 
 
N/A 
2.10.2.3 
Peak working voltage 
 
N/A 
2.10.3 
Clearances 
 
N/A 
2.10.3.1 
General 
 
N/A 
2.10.3.2 
Mains transient voltages 
 
N/A 
 
a) AC mains supply ................................................:   
N/A 
 
b) Earthed d.c. mains supplies  ..............................:   
N/A 
 
c) Unearthed d.c. mains supplies  ..........................:   
N/A 
 
d) Battery operation  ...............................................:   
N/A 
2.10.3.3 
Clearances in primary circuits 
(see appended table 2.10.3 
and 2.10.4)   
N/A 
2.10.3.4 
Clearances in secondary circuits 
(see appended table 2.10.3 
and 2.10.4)   
N/A 
2.10.3.5 
Clearances in circuits having starting pulses 
(see appended table 2.10.3 
and 2.10.4)   
N/A 
2.10.3.6 
Transients from a.c. mains supply .........................:   
N/A 
2.10.3.7 
Transients from d.c. mains supply .........................:   
N/A 
2.10.3.8 
Transients from telecommunication networks and 
cable distribution systems ......................................: 
 
N/A 
2.10.3.9 
Measurement of transient voltage levels 
 
N/A 
 
a) Transients from a mains suplply 
 
N/A 
 
For an a.c. mains supply ........................................:   
N/A 
 
Page 15 of 58 
Report No. 15039146 001 
 
 
 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
 
For a d.c. mains supply ..........................................:   
N/A 
 
b) Transients from a telecommunication network : 
 
N/A 
2.10.4 
Creepage distances 
 
N/A 
2.10.4.1 
General 
 
N/A 
2.10.4.2 
Material group and caomparative tracking index 
 
N/A 
 
CTI tests .................................................................:  Material group IIIb is assumed 
to be used 
 
2.10.4.3 
Minimum creepage distances 
(see appended table 2.10.3 
and 2.10.4) 
N/A 
2.10.5 
Solid insulation 
 
N/A 
2.10.5.1 
General 
 
N/A 
2.10.5.2 
Distances through insulation 
(see appended table 2.10.5)  
N/A 
2.10.5.3 
Insulating compound as solid insulation 
 
N/A 
2.10.5.4 
Semiconductor devices 
 
N/A 
2.10.5.5. 
Cemented joints 
(see appended table 2.10.3 
and 2.10.4) 
N/A 
2.10.5.6 
Thin sheet material – General 
 
N/A 
2.10.5.7 
Separable thin sheet material 
 
N/A 
 
Number of layers (pcs) ...........................................:   
 
2.10.5.8 
Non-separable thin sheet material 
 
N/A 
2.10.5.9 
Thin sheet material – standard test procedure 
 
N/A 
 
Electric strength test 
(see appended table 2.10.5)  
 
2.10.5.10 
Thin sheet material – alternative test procedure 
 
N/A 
 
Electric strength test 
(see appended table 2.10.5)  
 
2.10.5.11 
Insulation in wound components 
 
N/A 
2.10.5.12 
Wire in wound components 
 
N/A 
 
Working voltage .....................................................:   
N/A 
 
a) Basic insulation not under stress .......................:   
N/A 
 
b) Basic, supplemetary, reinforced insulation  ........:   
N/A 
 
c) Compliance with Annex U  .................................:   
N/A 
 
Two wires in contact inside wound component; 
angle between 45
°
 and 90
°
 ....................................: 
 
N/A 
2.10.5.13 
Wire with solvent-based enamel in wound 
components 
 
N/A 
 
Electric strength test 
(see appended table 2.10.5)  
 
 
Routine test  
 
N/A 
2.10.5.14 
Additional insulation in wound components 
 
N/A 
 
Working voltage .....................................................:   
N/A 
Page of 70