Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate ▷ View online
Page 28 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
G.4
Determination of required withstand voltage (V)
N/A
G.4.1
Mains transients and internal repetitive peaks ......:
N/A
G.4.2
Transients from telecommunication networks ......:
N/A
G.4.3
Combination of transients
N/A
G.4.4
Transients from cable distribution systems
N/A
G.5
Measurement of transient voltages (V)
N/A
a) Transients from a mains supply
N/A
For an a.c. mains supply
N/A
For a d.c. mains supply
N/A
b) Transients from a telecommunication network
N/A
G.6
Determination of minimum clearances .................:
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal(s) used ........................................................:
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) ........ :
N/A
K.3
Thermostat endurance test; operating voltage (V)
.............................................................................. :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) ........................................................................ :
(V) ........................................................................ :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
(see appended table 5.3)
N/A
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
P
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
Page 29 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
L.7
Other business equipment
The equipment is operated
according to the most
unfavorable way of operation
given in the operating
instructions.
according to the most
unfavorable way of operation
given in the operating
instructions.
P
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz) .....................................................:
M.3.1.2
Voltage (V) ............................................................:
M.3.1.3
Cadence; time (s), voltage (V) ..............................:
M.3.1.4
Single fault current (mA) .......................................:
M.3.2
Tripping device and monitoring voltage ................:
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V) ...........................................:
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N/A
a) Preferred climatic categories ............................:
N/A
b) Maximum continuous voltage ...........................:
N/A
c) Pulse current .....................................................:
N/A
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
Page 30 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
(see 1.1.2)
N/A
IPX2
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
INSULATION (see 2.10.5.4)
N/A
See separate test report
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1
Introduction
N/A
V.2
TN power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)
(see clause C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus ..................................................... :
N/A
Y.2
Mounting of test samples ..................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus ................... :
N/A
Y.4
Xenon-arc light exposure apparatus .................... :
N/A
Page 31 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N/A
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N/A
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
CC
ANNEX CC, Evaluation of integrated circuit (IC) current limiters
N/A
CC.1
General
N/A
CC.2
Test program 1……………………………………….:
N/A
CC.3
Test program 2……………………………………….:
N/A
DD
ANNEX DD, Requirements for the mounting means of rack-mounted
equipment
equipment
N/A
DD.1
General
N/A
DD.2
Mechanical strength test, variable N………………..:
N/A
DD.3
Mechanical strength test, 250N, including end
stops……………………………………………………:
stops……………………………………………………:
N/A
DD.4
Compliance……………………………………………:
N/A
EE
ANNEX EE, Household and home/office document/media shredders
N/A
EE.1
General
N/A
EE.2
Markings and instructions
N/A
Use of markings or symbols…………………………:
N/A
Information of user instructions, maintenance
and/or servicing instructions…………………………:
and/or servicing instructions…………………………:
N/A
EE.3
Inadvertent reactivation test…………………………:
N/A
EE.4
Disconnection of power to hazardous moving parts:
N/A
Use of markings or symbols…………………………:
N/A
EE.5
Protection against hazardous moving parts
N/A
Test with test finger (Figure 2A) ……………………:
N/A
Test with wedge probe (Figure EE1 and EE2) ……:
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.