Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate ▷ View online
ATTACHMENT
National Differences
Page 44 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2010-05-25
Finnish National Differences
FINNISH NATIONAL DIFFERENCES
1.5.9.4
The third dashed sentence is applicable only to
equipment as defined in 6.1.2.2 of this annex.
equipment as defined in 6.1.2.2 of this annex.
N/A
1.7.2.1
CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed
mains socket-outlet.
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed
mains socket-outlet.
The marking text shall be as follows:
"Laite on liitettävä suojakoskettimilla varustettuun
pistorasiaan"
pistorasiaan"
N/A
2.3.2
There are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
Remark: For 6.1.2.1 see
"European Group Differences
and National Differences".
"European Group Differences
and National Differences".
N/A
2.10.5.13
There are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
Remark: For 6.1.2.1 see
"European Group Differences
and National Differences".
"European Group Differences
and National Differences".
N/A
5.1.7.1
TOUCH CURRENT measurement results
exceeding 3,5 mA r.m.s. are permitted only for
the following equipment:
exceeding 3,5 mA r.m.s. are permitted only for
the following equipment:
•
STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
TYPE A that
o
is intended to be used in a
RESTRICTED ACCESS LOCATION
where equipotential bonding has
been applied, for example, in
telecommunication centre; and
RESTRICTED ACCESS LOCATION
where equipotential bonding has
been applied, for example, in
telecommunication centre; and
o
has provision for a permanently
connected PROTECTIVE
EARTHING CONDUCTOR; and
connected PROTECTIVE
EARTHING CONDUCTOR; and
o
is provided with instructions for the
installation of that conductor by a
SERVICE PERSON;
installation of that conductor by a
SERVICE PERSON;
•
STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
TYPE B;
•
STATIONARY PERMANENTLY
CONNECTED EQUIPMENT.
CONNECTED EQUIPMENT.
N/A
ATTACHMENT
National Differences
Page 45 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2010-05-25
Finnish National Differences
6.1.2.2
The exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT,
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
PERMANENTLY CONNECTED EQUIPMENT,
PLUGGABLE EQUIPMENT TYPE B and
equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has
provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR and is
provided with instructions for the installation of
that conductor by a SERVICE PERSON.
N/A
7.2
For requirements see 6.1.2.1 and 6.1.2.2 of this
annex. The term TELECOMMUNICATION
NETWORK in 6.1.2 being replaced by the term
CABLE DISTRIBUTION SYSTEM.
annex. The term TELECOMMUNICATION
NETWORK in 6.1.2 being replaced by the term
CABLE DISTRIBUTION SYSTEM.
N/A
ATTACHMENT
National Differences
Page 46 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2009-04-16
European Group Differences and National Differences
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Differences according to ................:
EN 60950-1:2006+A11:2009
CENELEC COMMON MODIFICATIONS (EN)
P
ZA
Normative references to international publications with their corresponding European
publications
publications
ZB
ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN)
P
1.2.13.14
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
1.7.2.1 and 7.3 of this annex.
The equipment is not
connected to the cable
distribution systems.
connected to the cable
distribution systems.
N/A
1.5.7.1
Replace the existing SNC by the following:
In Finland, Norway and Sweden, resistors
bridging
bridging
BASIC INSULATION
in
CLASS I PLUGGABLE
EQUIPMENT TYPE A
must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
No such components with the
equipment.
equipment.
N/A
1.7.2.1
Add as new SNC:
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and
similar information in Norwegian and
Swedish language respectively, depending on in
what country the equipment is intended to be
used in:
what country the equipment is intended to be
used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
The equipment is not
connected to the cable
distribution systems.
connected to the cable
distribution systems.
N/A
ATTACHMENT
National Differences
Page 47 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2009-04-16
European Group Differences and National Differences
60728-11).”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60
Hz, for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel- TV
nettet.”
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medf
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medf
ı
ra risk f
ı
r brand. F
ı
r att undvika
detta skall vid anslutning av utrustningen till
kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
1.7.5
Add the following paragraph to the existing SNC
for Denmark:
for Denmark:
For
CLASS II EQUIPMENT
the socket outlet shall be
in accordance with Standard Sheet DKA 1-4a.
The equipment is Class III
equipment and no socket outlet
provided.
equipment and no socket outlet
provided.
N/A
7.3
Delete the existing SNC for Norway and Sweden
(based on NOTE 1 of IEC 60950-1:2005 + corr.
1).
(based on NOTE 1 of IEC 60950-1:2005 + corr.
1).
Add as new SNC (based on future NOTE 3 of
IEC 60950-1:200X):
IEC 60950-1:200X):
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.
1.2.13.14 and 1.7.2.1 of this annex.
The equipment is not
connected to the distribution
systems.
connected to the distribution
systems.
N/A
ZC
ANNEX ZC, NATIONAL DEVIATIONS (EN)
P
1.5.1
Sweden
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
1.7.2.1
Denmark
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
1.7.5
Denmark
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
5.1.7.1
Denmark
Delete the A-deviation.
Delete the A-deviation.
Deleted.
N/A
Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.