ATTACHMENT
 
 
National Differences
 
 
 
Page 44 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2010-05-25
 
                                                                        
Finnish National Differences
 
 
FINNISH NATIONAL DIFFERENCES 
 
1.5.9.4 
The third dashed sentence is applicable only to 
equipment as defined in 6.1.2.2 of this annex. 
 
N/A 
1.7.2.1 
CLASS I PLUGGABLE EQUIPMENT TYPE A 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
accessible parts, have a marking stating that the 
equipment must be connected to an earthed 
mains socket-outlet. 
 
The marking text shall be as follows: 
 
"Laite on liitettävä suojakoskettimilla varustettuun 
pistorasiaan" 
 
N/A 
2.3.2 
There are additional requirements for the 
insulation. See 6.1.2.1 and 6.1.2.2 of this annex. 
Remark: For 6.1.2.1 see 
"European Group Differences 
and National Differences". 
N/A 
2.10.5.13 
There are additional requirements for the 
insulation. See 6.1.2.1 and 6.1.2.2 of this annex. 
Remark: For 6.1.2.1 see 
"European Group Differences 
and National Differences". 
N/A 
5.1.7.1 
TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s. are permitted only for 
the following equipment: 
 
STATIONARY PLUGGABLE EQUIPMENT 
TYPE A that 
o
 
is intended to be used in a 
RESTRICTED ACCESS LOCATION 
where equipotential bonding has 
been applied, for example, in 
telecommunication centre; and 
o
 
has provision for a permanently 
connected PROTECTIVE 
EARTHING CONDUCTOR; and 
o
 
is provided with instructions for the 
installation of that conductor by a 
SERVICE PERSON; 
 
STATIONARY PLUGGABLE EQUIPMENT 
TYPE B; 
 
STATIONARY PERMANENTLY 
CONNECTED EQUIPMENT. 
 
N/A 
ATTACHMENT
 
 
National Differences
 
 
 
Page 45 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2010-05-25
 
                                                                        
Finnish National Differences
 
 
6.1.2.2 
The exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT, 
PLUGGABLE EQUIPMENT TYPE B and 
equipment intended to be used in a 
RESTRICTED ACCESS LOCATION where 
equipotential bonding has been applied, e.g. in a 
telecommunication centre, and which has 
provision for a permanently connected 
PROTECTIVE EARTHING CONDUCTOR and is 
provided with instructions for the installation of 
that conductor by a SERVICE PERSON. 
 
N/A 
7.2 
For requirements see 6.1.2.1 and 6.1.2.2 of this 
annex. The term TELECOMMUNICATION 
NETWORK in 6.1.2 being replaced by the term 
CABLE DISTRIBUTION SYSTEM. 
 
N/A 
 
 
 
ATTACHMENT
 
 
National Differences
 
 
 
Page 46 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2009-04-16
                                                  
European Group Differences and National Differences 
 
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES 
Differences according to ................: 
EN 60950-1:2006+A11:2009 
 
 
CENELEC COMMON MODIFICATIONS (EN) 
ZA 
Normative references to international publications with their corresponding European 
publications 
 
 
ZB 
ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) 
1.2.13.14 
In Norway and Sweden, for requirements see 
1.7.2.1 and 7.3 of this annex. 
The equipment is not 
connected to the cable 
distribution systems. 
N/A 
1.5.7.1 
Replace the existing SNC by the following: 
In Finland, Norway and Sweden, resistors 
bridging 
BASIC INSULATION 
in 
CLASS I PLUGGABLE 
EQUIPMENT TYPE A 
must comply with the 
requirements in 1.5.7.1. In addition when a single 
resistor is used, the resistor must withstand the 
resistor test in 1.5.7.2. 
No such components with the 
equipment. 
N/A 
1.7.2.1 
Add as new SNC: 
In Norway and Sweden, the screen of the cable 
distribution system is normally not earthed at the 
entrance of the building and there is normally no 
equipotential bonding system within the building. 
Therefore the protective earthing of the building 
installation need to be isolated from the screen of 
a cable distribution system. 
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer. 
The user manual shall then have the following or 
similar information in Norwegian and 
Swedish language respectively, depending on in 
what country the equipment is intended to be 
used in: 
“Equipment connected to the protective earthing 
of the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing – and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device 
providing electrical isolation below a certain 
frequency range (galvanic isolator, see EN 
The equipment is not 
connected to the cable 
distribution systems. 
N/A 
ATTACHMENT
 
 
National Differences
 
 
 
Page 47 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2009-04-16
                                                  
European Group Differences and National Differences 
 
60728-11).” 
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 
Hz, for 1 min. 
Translation to Norwegian (the Swedish text will 
also be accepted in Norway):                              
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr – 
og er tilkoplet et kabel-TV nett, kan forårsake 
brannfare. For å unngå dette skal det ved 
tilkopling av utstyret til kabel-TV nettet installeres 
en galvanisk isolator mellom utstyret og kabel- TV 
nettet.” 
Translation to Swedish:                                  
 ”Utrustning som är kopplad till skyddsjord via 
jordat vägguttag och/eller via annan utrustning 
och samtidigt är kopplad till kabel-TV nät kan i 
vissa fall medf
ı
ra risk f
ı
r brand. F
ı
r att undvika 
detta skall vid anslutning av utrustningen till 
kabel-TV nät galvanisk isolator finnas mellan 
utrustningen och kabel-TV nätet.” 
1.7.5 
Add the following paragraph to the existing SNC 
for Denmark
For 
CLASS II EQUIPMENT 
the socket outlet shall be 
in accordance with Standard Sheet DKA 1-4a. 
The equipment is Class III 
equipment and no socket outlet 
provided. 
N/A 
7.3 
Delete the existing SNC for Norway and Sweden 
(based on NOTE 1 of IEC 60950-1:2005 + corr. 
1). 
Add as new SNC (based on future NOTE 3 of 
IEC 60950-1:200X): 
In Norway and Sweden, for requirements see 
1.2.13.14 and 1.7.2.1 of this annex. 
The equipment is not 
connected to the distribution 
systems. 
N/A 
 
ZC 
ANNEX ZC, NATIONAL DEVIATIONS (EN) 
1.5.1 
Sweden 
Delete the A-deviation. 
Deleted. 
N/A 
1.7.2.1 
Denmark 
Delete the A-deviation. 
Deleted. 
N/A 
1.7.5 
Denmark 
Delete the A-deviation. 
Deleted. 
N/A 
5.1.7.1 
Denmark 
Delete the A-deviation. 
Deleted. 
N/A 
 