Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2007-05-29
Canadian National Differences
4.2.8.1
Enclosures around CRTs with a face diameter of
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
No CRT.
N/A
4.2.11
For equipment intended for mounting on racks
and provided with slide/rails allowing the
equipment to slide away from the rack for
installation, service and maintenance, additional
construction, performance and marking
requirements are applicable to determine the
adequacy of the slide/rails.
and provided with slide/rails allowing the
equipment to slide away from the rack for
installation, service and maintenance, additional
construction, performance and marking
requirements are applicable to determine the
adequacy of the slide/rails.
The equipment is not such
equipment.
equipment.
N/A
4.3.2
Equipment with handles is required to comply with
special loading tests.
special loading tests.
No handles provided.
N/A
5.1.8.3
Equipment intended to receive telecommunication
ringing signals is required to comply with a special
touch current measurement tests.
ringing signals is required to comply with a special
touch current measurement tests.
No TNV circuits within the
equipment.
equipment.
N/A
5.3.7
Internal (e.g., card cage) SELV circuit connectors
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.
and printed wiring board connectors that are
accessible to the operator and that deliver power
are to be overloaded.
During abnormal operating testing, if a circuit is
interrupted by the opening of a component, the
test shall be repeated twice (three tests total)
using new components as necessary.
interrupted by the opening of a component, the
test shall be repeated twice (three tests total)
using new components as necessary.
See appended table 5.3 of IEC
60950-1 test report.
60950-1 test report.
P
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV circuits within the
equipment.
equipment.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuits within the
equipment.
equipment.
N/A
Annex
NAD
NAD
Equipment connected to a telecommunication
and cable distribution networks and supplied with
an earphone intended to be held against, or in the
ear is required to comply with special acoustic
pressure requirements.
and cable distribution networks and supplied with
an earphone intended to be held against, or in the
ear is required to comply with special acoustic
pressure requirements.
No TNV circuits within the
equipment.
equipment.
N/A
Annex
NAF
NAF
Document (paper) shredders likely to be used in a
home or home office (Pluggable Equipment Type
A plug configuration) are required to comply with
additional requirements, including
markings/instructions, protection against
inadvertent reactivation of a safety interlock,
disconnection from the mains supply (via
provision of an isolating switch), and protection
against operator access (accessibility determined
via new accessibility probe & probe/wedge).
home or home office (Pluggable Equipment Type
A plug configuration) are required to comply with
additional requirements, including
markings/instructions, protection against
inadvertent reactivation of a safety interlock,
disconnection from the mains supply (via
provision of an isolating switch), and protection
against operator access (accessibility determined
via new accessibility probe & probe/wedge).
The equipment is not such
equipment.
equipment.
N/A
ATTACHMENT
National Differences
Page 53 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2007-08-08
Korean National Differences
Korean National Differences
P
Corresponding National Standard: K 60950-1
P
1.5.101
Addition:
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305).
supply mains shall comply with the Korean
requirement (KSC 8305).
Class III equipment.
N/A
8
Addition: EMC
The apparatus shall comply with the relevant
CISPR standards.
CISPR standards.
The requirements of CISPR
have to be considered during
the national approval.
have to be considered during
the national approval.
N/A
ATTACHMENT
National Differences
Page 54 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2007-08-08
US National Differences
US National Differences
P
SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS
1.1.1
All equipment is to be designed to allow
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, and when
applicable, the National Electrical Safety Code,
IEEE C2. Also, unless marked or otherwise
identified, installation is allowed per the Standard
for the Protection of Electronic Computer/Data-
Processing Equipment, ANSI/NFPA 75.
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, and when
applicable, the National Electrical Safety Code,
IEEE C2. Also, unless marked or otherwise
identified, installation is allowed per the Standard
for the Protection of Electronic Computer/Data-
Processing Equipment, ANSI/NFPA 75.
The equipment was evaluated
according to IEC 60950-1.
according to IEC 60950-1.
The requirements have to be
checked during the national
approval.
checked during the national
approval.
N/A
1.4.14
For Pluggable Equipment Type A, the protection
in the installation is assumed to be 20A.
in the installation is assumed to be 20A.
Class III equipment.
N/A
1.5.5
For lengths exceeding 3.05 m, external
interconnecting flexible cord and cable
assemblies are required to be a suitable cable
type specified in the NEC. For lengths 3.05 m or
less, external interconnecting flexible cord and
cable assemblies that are not types specified in
the NEC are required to have special construction
features and identification markings.
interconnecting flexible cord and cable
assemblies are required to be a suitable cable
type specified in the NEC. For lengths 3.05 m or
less, external interconnecting flexible cord and
cable assemblies that are not types specified in
the NEC are required to have special construction
features and identification markings.
Shall be evaluated during the
national approval for the
external interconnecting flexible
cord and cable assemblies.
national approval for the
external interconnecting flexible
cord and cable assemblies.
N/A
1.7.1
Equipment for use on a.c. mains supply systems
with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
with a neutral and more than one phase
conductor (e.g. 120/240 V, 3-wire) require a
special marking format for electrical ratings.
Not directly connected to the
mains.
mains.
N/A
2.5
Where a fuse is used to provide Class 2, Limited
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
Power Source, or TNV current limiting, it shall not
be operator-accessible unless it is not
interchangeable.
No fuses used for these
purpose.
purpose.
N/A
2.7.1
Suitable NEC branch circuit protection rated at
the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable. Power
distribution transformers distributing power at 100
volts or more, and rated 10 kVA or more, require
special transformer overcurrent protection.
the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable. Power
distribution transformers distributing power at 100
volts or more, and rated 10 kVA or more, require
special transformer overcurrent protection.
No standard supply outlets,
receptacles, medium-base or
smaller lampholders provided.
receptacles, medium-base or
smaller lampholders provided.
N/A
3.2
Wiring methods (terminals, leads, etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC.
the connection of the equipment to the mains
shall be in accordance with the NEC.
Not directly connected to the
mains.
mains.
N/A
3.2.1
Power supply cords are required to have
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instruction requirements.
N/A
ATTACHMENT
National Differences
Page 55 of 58
Report No.:
15039146 001
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
IECEE CB Bulletin on 2007-08-08
US National Differences
3.2.3
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
N/A
3.2.5
Power supply cords are required to be no longer
than 4.5 m in length and minimum length shall be
1.5 m. Flexible power supply cords are required to
be compatible with Article 400 of the NEC.
than 4.5 m in length and minimum length shall be
1.5 m. Flexible power supply cords are required to
be compatible with Article 400 of the NEC.
N/A
3.2.9
Permanently connected equipment must have a
suitable wiring compartment and wire bending
space.
suitable wiring compartment and wire bending
space.
N/A
3.3.3
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm
conductors larger than 10 AWG (5.3 mm
2
).
N/A
3.3.4
Terminals for permanent wiring, including
protective earthing terminals, must be suitable for
U.S wire gauge sizes, rated 125 percent of the
equipment rating, and be specially marked when
specified (1.7.7).
protective earthing terminals, must be suitable for
U.S wire gauge sizes, rated 125 percent of the
equipment rating, and be specially marked when
specified (1.7.7).
N/A
3.4.2
Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V,
or is rated more than 1/3 hp (locked rotor current
over 43 A).
connected equipment with a motor if the
equipment is rated more than 12 A, or if the motor
has a nominal voltage rating greater than 120 V,
or is rated more than 1/3 hp (locked rotor current
over 43 A).
No motor control devices.
N/A
3.4.8
Vertically-mounted disconnect switches and
circuit breakers are required to have the "on"
position indicated by the handle in the up position.
circuit breakers are required to have the "on"
position indicated by the handle in the up position.
No such switches and circuit
breakers.
breakers.
N/A
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
No battery systems.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment is required to comply with NFPA 30.
in equipment is required to comply with NFPA 30.
No flammable liquid.
N/A
4.3.13.5
Equipment with lasers is required to meet the
Code of Federal Regulations 21 CFR 1040.
Code of Federal Regulations 21 CFR 1040.
No Laser.
N/A
4.7
For computer room applications, automated
information storage systems with combustible
media greater than 0.76 m3 (27 cu ft) are
required to have a provision for connection of
either automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
information storage systems with combustible
media greater than 0.76 m3 (27 cu ft) are
required to have a provision for connection of
either automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
Not automated information
storage systems.
storage systems.
N/A