National Differences
 
 
 
Page 52 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2007-05-29
                                                                                                  
Canadian National Differences 
 
4.2.8.1 
Enclosures around CRTs with a face diameter of 
160 mm or more are required to reduce the risk of 
injury due to the implosion of the CRT. 
No CRT. 
N/A 
4.2.11 
For equipment intended for mounting on racks 
and provided with slide/rails allowing the 
equipment to slide away from the rack for 
installation, service and maintenance, additional 
construction, performance and marking 
requirements are applicable to determine the 
adequacy of the slide/rails. 
The equipment is not such 
equipment. 
N/A 
4.3.2 
Equipment with handles is required to comply with 
special loading tests. 
No handles provided. 
N/A 
5.1.8.3 
Equipment intended to receive telecommunication 
ringing signals is required to comply with a special 
touch current measurement tests.  
No TNV circuits within the 
equipment. 
N/A 
5.3.7 
Internal (e.g., card cage) SELV circuit connectors 
and printed wiring board connectors that are 
accessible to the operator and that deliver power 
are to be overloaded.  
During abnormal operating testing, if a circuit is 
interrupted by the opening of a component, the 
test shall be repeated twice (three tests total) 
using new components as necessary. 
See appended table 5.3 of IEC 
60950-1 test report. 
6.4 
Equipment intended for connection to 
telecommunication network outside plant cable is 
required to be protected against overvoltage from 
power line crosses in accordance with 6.4 and 
Annex NAC. 
No TNV circuits within the 
equipment. 
N/A 
M.2 
Continuous ringing signals up to 16 mA only are 
permitted if the equipment is subjected to special 
installation and performance restrictions. 
No TNV circuits within the 
equipment. 
N/A 
Annex 
NAD 
Equipment connected to a telecommunication 
and cable distribution networks and supplied with 
an earphone intended to be held against, or in the 
ear is required to comply with special acoustic 
pressure requirements. 
No TNV circuits within the 
equipment. 
N/A 
Annex 
NAF 
Document (paper) shredders likely to be used in a 
home or home office (Pluggable Equipment Type 
A plug configuration) are required to comply with 
additional requirements, including 
markings/instructions, protection against 
inadvertent reactivation of a safety interlock, 
disconnection from the mains supply (via 
provision of an isolating switch), and protection 
against operator access (accessibility determined 
via new accessibility probe & probe/wedge).  
The equipment is not such 
equipment. 
N/A 
 
 
ATTACHMENT
 
 
National Differences
 
 
 
Page 53 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2007-08-08
                                                                                                       
Korean National Differences  
 
 
Korean National Differences  
 
Corresponding National Standard: K 60950-1 
1.5.101 
Addition: 
Plugs for the connection of the apparatus to the 
supply mains shall comply with the Korean 
requirement (KSC 8305). 
Class III equipment.  
N/A 
Addition: EMC 
The apparatus shall comply with the relevant 
CISPR standards. 
The requirements of CISPR 
have to be considered during 
the national approval. 
N/A 
 
 
 
 
 
 
 
 
ATTACHMENT
 
 
National Differences
 
 
 
Page 54 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2007-08-08
                                                                                                               
US National Differences 
 
 
US National Differences 
SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS 
1.1.1  
All equipment is to be designed to allow 
installation in accordance with the National 
Electrical Code (NEC), ANSI/NFPA 70, and when 
applicable, the National Electrical Safety Code, 
IEEE C2.  Also, unless marked or otherwise 
identified, installation is allowed per the Standard 
for the Protection of Electronic Computer/Data-
Processing Equipment, ANSI/NFPA 75.  
The equipment was evaluated 
according to IEC 60950-1.   
The requirements have to be 
checked during the national 
approval. 
N/A 
1.4.14  
For Pluggable Equipment Type A, the protection 
in the installation is assumed to be 20A.  
Class III equipment.  
N/A 
1.5.5  
For lengths exceeding 3.05 m, external 
interconnecting flexible cord and cable 
assemblies are required to be a suitable cable 
type specified in the NEC. For lengths 3.05 m or 
less, external interconnecting flexible cord and 
cable assemblies that are not types specified in 
the NEC are required to have special construction 
features and identification markings.  
Shall be evaluated during the 
national approval for the 
external interconnecting flexible 
cord and cable assemblies. 
 
 
N/A 
1.7.1  
Equipment for use on a.c. mains supply systems 
with a neutral and more than one phase 
conductor (e.g. 120/240 V, 3-wire) require a 
special marking format for electrical ratings.  
Not directly connected to the 
mains.  
N/A 
2.5  
Where a fuse is used to provide Class 2, Limited 
Power Source, or TNV current limiting, it shall not 
be operator-accessible unless it is not 
interchangeable.  
No fuses used for these 
purpose. 
N/A 
2.7.1  
Suitable NEC branch circuit protection rated at 
the maximum circuit rating is required for all 
standard supply outlets and receptacles (such as 
supplied in power distribution units) if the supply 
branch circuit protection is not suitable.  Power 
distribution transformers distributing power at 100 
volts or more, and rated 10 kVA or more, require 
special transformer overcurrent protection.  
No standard supply outlets, 
receptacles, medium-base or 
smaller lampholders provided. 
N/A 
3.2  
Wiring methods (terminals, leads, etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC.  
Not directly connected to the 
mains.  
N/A 
3.2.1  
Power supply cords are required to have 
attachment plugs rated not less than 125 percent 
of the rated current of the equipment.  
 
N/A 
3.2.1.2  
Equipment connected to a centralized d.c. power 
system, and having one pole of the DC mains 
input terminal connected to the main protective 
earthing terminal in the equipment, is required to 
comply with special earthing, wiring, marking and 
installation instruction requirements.  
 
N/A 
ATTACHMENT
 
 
National Differences
 
 
 
Page 55 of 58
 
 
Report No.:
 
15039146 001
 
National Differences
 
Clause
 
Requirement 
 Test
 
Result – Remark
 
Verdict
 
 
IECEE CB Bulletin on 2007-08-08
                                                                                                               
US National Differences 
 
3.2.3  
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs.  
 
N/A 
3.2.5  
Power supply cords are required to be no longer 
than 4.5 m in length and minimum length shall be 
1.5 m. Flexible power supply cords are required to 
be compatible with Article 400 of the NEC.  
 
N/A 
3.2.9  
Permanently connected equipment must have a 
suitable wiring compartment and wire bending 
space.  
 
N/A 
3.3.3  
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm
2
).  
 
N/A 
3.3.4  
Terminals for permanent wiring, including 
protective earthing terminals, must be suitable for 
U.S wire gauge sizes, rated 125 percent of the 
equipment rating, and be specially marked when 
specified (1.7.7).  
 
N/A 
3.4.2  
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12 A, or if the motor 
has a nominal voltage rating greater than 120 V, 
or is rated more than 1/3 hp (locked rotor current 
over 43 A).  
No motor control devices. 
N/A 
3.4.8  
Vertically-mounted disconnect switches and 
circuit breakers are required to have the "on" 
position indicated by the handle in the up position.  
No such switches and circuit 
breakers. 
N/A 
3.4.11  
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit.  
No battery systems. 
N/A 
4.3.12  
The maximum quantity of flammable liquid stored 
in equipment is required to comply with NFPA 30.  
No flammable liquid. 
N/A 
4.3.13.5  
Equipment with lasers is required to meet the 
Code of Federal Regulations 21 CFR 1040.  
No Laser. 
N/A 
4.7  
For computer room applications, automated 
information storage systems with combustible 
media greater than 0.76 m3 (27 cu ft) are 
required to have a provision for connection of 
either automatic sprinklers or a gaseous agent 
extinguishing system with an extended discharge.  
Not automated information 
storage systems.  
N/A 