Harman Kardon GO PLAY MICRO (serv.man2) EMC - CB Certificate ▷ View online
Page 4 of 58
Report No. 15039146 001
TRF No. IEC60950_1B
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
the respective NCBs that own these marks.
Page 5 of 58
Report No. 15039146 001
TRF No. IEC60950_1B
Test item particulars...................................................:
Equipment mobility.....................................................: [X] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................: [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition ....................................................: [X] continuous
[] rated operating / resting time:
Access location .........................................................: [X] operator accessible
[] restricted access location
Over voltage category (OVC) ....................................: [] OVC I [] OVC II [] OVC III [] OVC IV
[X] other: Not directly connected to the mains
Mains supply tolerance (%) or absolute mains supply
values ........................................................................:
values ........................................................................:
N/A
Tested for IT power systems ....................................: [] Yes [] No
IT testing, phase-phase voltage (V) ..........................: N/A
Class of equipment ...................................................: [] Class I [] Class II [X] Class III
[] Not classified
Considered current rating of protective device as part
of the building installlation (A) ...................................:
of the building installlation (A) ...................................:
Pollution degree (PD) ................................................: [] PD 1 [X] PD 2 [] PD 3
IP protection class .....................................................: IPX0
Altitude during operation (m) .....................................: Up to 2000
Altitude of test laboratory (m) ....................................: Less than 2000
Mass of equipment (kg) ............................................: 3.9
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A (or N)
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement................. : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ............................................ : August, 2010
Date(s) of performance of tests.................................... : August, 2010
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Additional tests were carried out according to EN 60950-1: 2006 + A11: 2009 + A1: 2010.
Page 6 of 58
Report No. 15039146 001
TRF No. IEC60950_1B
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided.................................................................:
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided.................................................................:
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Guoguang Electric Company., Limited. (GGEC)
No 8 Jinghu Road, Xinhua Street, Huadu Reg,
Guangzhou, Guangdong 510800, P. R. China
Guangzhou, Guangdong 510800, P. R. China
General product information:
The EUT is a computer stereo system speaker for the use within the scope of IEC/EN 60950-1.
The EUT is supplied power from DC input jack by a switching power supply adapter which was compliance
with sub-clause 2.5 as Limited Power Source. It can also be powered by 8 C size batteries.
with sub-clause 2.5 as Limited Power Source. It can also be powered by 8 C size batteries.
The switching power supply adapters were tested and approved by Intertek ETL SEMKO (for details see
Table 1.5.1), adapter was not evaluated as a part in this report and a sample of the equipment was
subjected to a construction check and accepted during this approval.
Table 1.5.1), adapter was not evaluated as a part in this report and a sample of the equipment was
subjected to a construction check and accepted during this approval.
The test samples are engineering samples without serial number.
Engineering Considerations
•
The product was submitted and tested for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 25°C
permitted by the manufacturer’s specification of: 25°C
•
The means of connection to the mains supply is not directly connected to the mains
MARKINGS AND INSTRUCTIONS
The product also marked with:
•
(IEC 60417-5009) for the stand-by condition. (See subclause 1.7.8.3)
Abbreviations used in the report:
- normal conditions
N.C.
- single fault conditions
S.F.C
- functional insulation
OP
- basic insulation
BI
- double insulation
DI
- supplementary insulation
SI
- between parts of opposite
polarity
polarity
BOP
- reinforced insulation
RI
- short-circuit S-C - equipment under test
EUT
Indicate used abbreviations (if any)
Page 7 of 58
Report No. 15039146 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1
GENERAL
P
1.5
Components
P
1.5.1
General
See below.
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended tables 1.5.1)
P
1.5.2
Evaluation and testing of components
Components certified to EN
standards and/or their
harmonized standards, are
used within their ratings and
are checked for correct
application.
standards and/or their
harmonized standards, are
used within their ratings and
are checked for correct
application.
P
1.5.3
Thermal controls
Not used.
N/A
1.5.4
Transformers
Not used.
N/A
1.5.5
Interconnecting cables
Interconnection cable
provided with the equipment is
carrying signals on energy
level below 240 VA.
provided with the equipment is
carrying signals on energy
level below 240 VA.
Besides for the insulation
materials, there are not other
requirements for the
interconnection cable.
materials, there are not other
requirements for the
interconnection cable.
P
1.5.6
Capacitors bridging insulation
No such capacitors.
N/A
1.5.7
Resistors bridging insulation
No such resistors.
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9
Surge suppressors
Not used.
N/A
1.5.9.1
General
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
N/A
1.6
Power interface
P
1.6.1
AC power distribution systems
Class III equipment.
P
Click on the first or last page to see other GO PLAY MICRO (serv.man2) service manuals if exist.