Harman Kardon BDS 577 EMC - CB Certificate ▷ View online
Page 25 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CN China
CN
1.1.3
Amended the first paragraph:
This standard applies to apparatus
intended to be used basically at
altitudes not exceeding 5 000 m, dry
climate at warm temperate zone or
tropical climates.
This standard applies to apparatus
intended to be used basically at
altitudes not exceeding 5 000 m, dry
climate at warm temperate zone or
tropical climates.
N/A
The fourth paragraph replaced by
following:
For apparatus intended to be used in
vehicles, ships or aircraft, or at altitudes
exceeding
5 000m, additional requirements may
be necessary.
following:
For apparatus intended to be used in
vehicles, ships or aircraft, or at altitudes
exceeding
5 000m, additional requirements may
be necessary.
N/A
5
At the end of the first paragraph ,added
following:
For apparatus intended to be used at
altitude not exceeding 2000m, a
warning label containing the following or
a similar appropriate wording or a
symbol as in annex R(see following)
shall fixed to the equipment at readily
visible place.
"Only used at altitude not exceeding
2000m."
following:
For apparatus intended to be used at
altitude not exceeding 2000m, a
warning label containing the following or
a similar appropriate wording or a
symbol as in annex R(see following)
shall fixed to the equipment at readily
visible place.
"Only used at altitude not exceeding
2000m."
If only symbol used, the explanation of
the symbol shall be contained in the
instruction manual.
the symbol shall be contained in the
instruction manual.
For apparatus intended to be used in
not-tropical climate regions, a warning
label containing the following or a
similar appropriate wording or a symbol
as in annex R shall fixed to the
equipment at readily visible place.
"Only used in not-tropical climate
regions."
not-tropical climate regions, a warning
label containing the following or a
similar appropriate wording or a symbol
as in annex R shall fixed to the
equipment at readily visible place.
"Only used in not-tropical climate
regions."
If only symbol used, the explanation of
the symbol shall be contained in the
instruction manual.
the symbol shall be contained in the
instruction manual.
Should be evaluated during national
approval
approval
N/A
Page 26 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CN China
CN
The statements above shall be given in
a language acceptable to the regions
where the apparatus is intended to be
used.
a language acceptable to the regions
where the apparatus is intended to be
used.
5.1 e)
After the last paragraph, added:
…….For single rated voltage, ―220 V‖ or
three-
…….For single rated voltage, ―220 V‖ or
three-
phase ―380V‖ shall be marked
only. For a rating range, 220 V or three-
phase 380V shall be covered. For
multiple rated voltages, one of them
shall be 220 V or three-phase 380V and
which default setting from manufacture
shall be 220 V or three-phase 380V as
well.
phase 380V shall be covered. For
multiple rated voltages, one of them
shall be 220 V or three-phase 380V and
which default setting from manufacture
shall be 220 V or three-phase 380V as
well.
Should be evaluated during national
approval
approval
N/A
5.1 f)
After the first sentence, Added:
……for Rated MAINS frequency or
frequency range shall be 50Hz or
covered 50Hz.
……for Rated MAINS frequency or
frequency range shall be 50Hz or
covered 50Hz.
Should be evaluated during
national approval
national approval
N/A
5.4
Replaced the second sentence of the
first paragraph:
This information shall be given in
normative Chinese.
first paragraph:
This information shall be given in
normative Chinese.
N/A
5.4.1i)
Added new paragraph i),after the h)
paragraph:
i) For apparatus incorporating antenna
coaxial sockets witch is non-separated
with CATV network, a warning wording
or a similar shall be given in the
instructions manual:
―The CATV network connecting to this
apparatus shall separate from
protective earth, otherwise it may cause
fire or other
paragraph:
i) For apparatus incorporating antenna
coaxial sockets witch is non-separated
with CATV network, a warning wording
or a similar shall be given in the
instructions manual:
―The CATV network connecting to this
apparatus shall separate from
protective earth, otherwise it may cause
fire or other
hazard.‖
N/A
7 ,Table3
Note a) of table 3 replaced:
This standard applies to apparatus
intended to be used in tropical climates,
permissible temperature rises are 10 K
less than those specified in the table.
For apparatus intended to be used in
non-tropical climates the limits in Table
3 are satisfactory.
This standard applies to apparatus
intended to be used in tropical climates,
permissible temperature rises are 10 K
less than those specified in the table.
For apparatus intended to be used in
non-tropical climates the limits in Table
3 are satisfactory.
N/A
7.1
Added Note 3:
For apparatus intended to be operated
at altitudes between 2 000m and 5
000m, temperature measuring
For apparatus intended to be operated
at altitudes between 2 000m and 5
000m, temperature measuring
N/A
Page 27 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CN China
CN
conditions and maximum temperature
limits are under consideration.
limits are under consideration.
9.1.1.1
Delete the note 3 and renumber the
existing note 4 as 3.
existing note 4 as 3.
N/A
9.1.1.1
After the paragraph of d), added a
paragraph:
For apparatus intended to be used in
tropical climates, the limits should be
halved than the values given in a) and
b) above.
paragraph:
For apparatus intended to be used in
tropical climates, the limits should be
halved than the values given in a) and
b) above.
N/A
10
Added a paragraph after the second
paragraph :
The Insulation resistance between
CATV antenna coaxial sockets and
protective earth of apparatus shall
comply with BASIC INSULATION. If it‘s
possible that CLASS II apparatus with
CATV antenna coaxial sockets connect
with protective earth of another CLASS
I apparatus by other terminals, the
insulation resistance between them
shall comply with BASIC INSULATION
as well.
Added Note:
if antenna cable separated from the
protective earth before connection to
the apparatus, there is no requirements
of Insulation resistance between them
but 5.4.1i) requirements shall be meet.
paragraph :
The Insulation resistance between
CATV antenna coaxial sockets and
protective earth of apparatus shall
comply with BASIC INSULATION. If it‘s
possible that CLASS II apparatus with
CATV antenna coaxial sockets connect
with protective earth of another CLASS
I apparatus by other terminals, the
insulation resistance between them
shall comply with BASIC INSULATION
as well.
Added Note:
if antenna cable separated from the
protective earth before connection to
the apparatus, there is no requirements
of Insulation resistance between them
but 5.4.1i) requirements shall be meet.
N/A
10.1
Delete ―on CLASS II apparatus‖ in the
first paragraph.
first paragraph.
Should be evaluated during national
approval
approval
N/A
10.2
Replaced the fifth to seventh
paragraphs by the following:
The humidity treatment is carried out in
a chamber containing air with a relative
humidity of 93%±3 %.
For apparatus, temperature of 40℃±2℃
and a relative humidity of 93%±3% shall
be subjected.
Apparatus intended to be used in non-
tropical climates are subjected to a
relative humidity of 93%±3%.
The temperature in the chamber, at all
places where samples located, shall be
paragraphs by the following:
The humidity treatment is carried out in
a chamber containing air with a relative
humidity of 93%±3 %.
For apparatus, temperature of 40℃±2℃
and a relative humidity of 93%±3% shall
be subjected.
Apparatus intended to be used in non-
tropical climates are subjected to a
relative humidity of 93%±3%.
The temperature in the chamber, at all
places where samples located, shall be
N/A
Page 28 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CN China
CN
maintained within 2℃of any convenient
value between 20℃ and 30℃, as long
as no condensation occur.
value between 20℃ and 30℃, as long
as no condensation occur.
Added Note 4: For apparatus intended
to be operated at altitudes between 2
000m and 5 000m , the requirements
for treatment of the insulating material
are under consideration.
to be operated at altitudes between 2
000m and 5 000m , the requirements
for treatment of the insulating material
are under consideration.
N/A
11.1
Delete note 2.
N/A
11.1
After the ninth paragraph added a
paragraph:
For apparatus intended to be used in
tropical climates, halve the values given
above.
paragraph:
For apparatus intended to be used in
tropical climates, halve the values given
above.
N/A
12.5
Amended the first paragraph :
Antenna coaxial sockets to be mounted
on the apparatus shall subject to
mechanical stress caused in use, and
the sockets incorporate with parts or
components which isolated
HAZARDOUS LIVE parts from
ACCESSIBLE parts or protective earth
from other terminals.
Antenna coaxial sockets to be mounted
on the apparatus shall subject to
mechanical stress caused in use, and
the sockets incorporate with parts or
components which isolated
HAZARDOUS LIVE parts from
ACCESSIBLE parts or protective earth
from other terminals.
N/A
13.3.2
Table 8 、
Table 9 、
Table1 0
Table 8 、
Table 9 、
Table1 0
After the first paragraph, added a
paragraph:
The requirements apply to apparatus
intended to be used at altitude not
exceeding 2 000 m . For apparatus
intended to be operated at altitudes
between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with
multiplication factor 1.48 in table A.2 of
GB/T 16935.1. For apparatus intended
to be operated at altitude more than 5
000m , Minimum CLEARANCES limit
shall multiply with relevant multiplication
factor in table A.2 of GB/T 16935.1.
paragraph:
The requirements apply to apparatus
intended to be used at altitude not
exceeding 2 000 m . For apparatus
intended to be operated at altitudes
between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with
multiplication factor 1.48 in table A.2 of
GB/T 16935.1. For apparatus intended
to be operated at altitude more than 5
000m , Minimum CLEARANCES limit
shall multiply with relevant multiplication
factor in table A.2 of GB/T 16935.1.
N/A
Bellow the headings of Table 8 Table 9
and Table 10 ,added :
―(Applicable for altitude up to
2000m)
and Table 10 ,added :
―(Applicable for altitude up to
2000m)
‖ .
N/A
Amended Table 9 Note 2:
For operating voltage values exceeding
For operating voltage values exceeding
N/A
Click on the first or last page to see other BDS 577 service manuals if exist.