Page 13 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
 
CA  Canada 
CA 
1.1.1 
Add the following paragraph and note: 
This Standard applies to the safety of such 
equipment designed to be installed and used in 
accordance with the rules of the Canadian 
Electrical Code (CEC), Part I. 
Note 4A:  Manufacturers designing products for 
use in Canada may find a helpful summary of the 
equipment-related requirement of the CEC, Part 
I, in CSA SPE-2000. 
 
1.2 
Normative references 
Where reference is made to CSA Publications, 
such reference shall be considered to refer to the 
latest edition and all amendments published to 
that edition. This Standard refers to the following 
Standards, and the years shown indicate the 
latest editions available at the time of printing. 
ANSI/IEEE Standard 
C62.1-1984, Surge Arresters for Alternating-
Current Power Circuits 
CSA Standards 
C22.1-02, Canadian Electrical Code, Part 1 
CAN/CSA-C22.2 No. 0-M91 (R2001), General 
Requirements - Canadian Electrical Code, Part II 
C22.2 No. 0.4-M1982 (R1999), Bonding and 
Grounding of Electrical Equipment (Protective 
Grounding) 
C22.2 No. 0.15-01, Adhesive Labels 
CAN/CSA-C22.2 No. 1-98, Audio, Video and 
Similar Electronic Equipment 
CAN/CSA-C22.2 No. 21-95 (R1999), Cord Sets 
and Power Supply Cords 
C22.2 No. 39-M1987 (R1999), Fuseholder 
Assemblies 
C22.2 No. 42-99, General Use Receptacles, 
Attachment Plugs, and Similar Wiring Devices 
CAN/CSA-C22.2 No. 49-98, Flexible Cords and 
Cables 
CAN/CSA-C22.2 No. 94-M91 (R2001), Special 
Purpose Enclosures 
C22.2 No. 127-99, Equipment and Lead Wires 
C22.2 No. 209-M1985 (R1999), Thermal Cut-Offs 
CAN/CSA-C22.2 No. 210.2-M90 (R2001), 
Appliance Wiring Material Products 
CAN/CSA-C22.2 No. 223-M91 (1999), Power 
 
Page 14 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
CA  Canada 
CA 
Supplies with Extra-Low-Voltage Class 2 Outputs  
CAN/CSA-C22.2 No. 228-92 (1999), Cathode 
Ray Tubes 
CAN/CSA-C22.2 No. 248.14-00, Low Voltage 
Fuses - Part 14 
Spe-2000-94, Guide for Electrical Equipment for 
Installation and Use in Canada 
IEC Standards 
60038:2002, IEC standard voltages 
60083:1975, Plug and socket-outlets for domestic 
and similar general use. 
60173:1964, Colours of the cores of flexible 
cables and cords. 
60320 (all parts), Appliance couplers for 
household and similar general purposes. 
60707:1981, Methods of test for the 
determination of the flammability of solid electrical 
insulating materials. 
60884 (all parts), Plugs and socket-outlets for 
household and similar purposes. 
60906-1:1986, IEC System of plugs and socket-
outlets for household and similar purposes - Part 
1: Plugs and socket-outlets 16A 250V ac. 
60906-2:1997, IEC System of plugs and socket-
outlets for household and similar purposes - Part 
2: Plugs and socket-outlets 15A 125V ac. 
60906-3:1994, IEC System of plugs and socket-
outlets for household and similar purposes - Part 
3: SELV plugs and socket-outlets 16A 6V, 12V, 
24V, 48V ac and dc. 
3.2A 
Add the following clause: 
A component power supply complying with 
CAN/CSA-C22.2 No. 60950 is considered to 
comply with this construction and fault conditions 
of this Standard after taking into account any 
relevant conditions of acceptability. 
 
N/A 
4.2.1 
Add the following after the fifth paragraph: 
For apparatus intended for use at nominal 120V 
ac, the apparatus shall comply with this standard 
at supply voltages between 108V and 125V.  For 
apparatus intended for use at nominal 240V ac 
the apparatus shall comply with this standard at 
supply voltages between 216V and 250V.   
 
N/A 
Page 15 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
CA  Canada 
CA 
4.2.10 
Add the following after the second paragraph:   
As an alternative, a supply apparatus for general 
use complying with CSA/CSA-C22.2 No. 223 or 
CAN/CSA-C22.2 No. 60950 shall be acceptable. 
 
N/A 
Markings and instructions 
– adhesive nameplates 
Add the following paragraph: 
Adhesive nameplates on commercial products 
shall comply with CSA C22.2 No 0.15. 
 
5.1 
Add the following item: 
j) Date of manufacture: a date or code identifying 
the period of manufacture shall be marked on the 
apparatus;  
Manufactured  May 2012 
5.3A 
Add the following clause: 
Where a loudspeaker grille, removable from the 
outside, is relied on as part of the enclosure (see 
Clause 9.2), the following marking or equivalent 
shall be visible on the enclosure after removal of 
the grille: 
"Caution - To prevent electric shock hazard, 
replace grille." 
Alternatively, the symbol in Clause 5.2 b) shall be 
visible after removal of the grille, and the caution 
wording above shall appear in the user 
instructions, accompanied by the symbol. 
Compliance is checked by inspection. 
 
N/A 
8.9 
Add the following title to this clause: 
Mains Wiring 
Add the following paragraph: 
Wiring in circuits with voltages higher than 42V 
peak shall comply with CSA C22.2 No 127 or 
CAN/CSA C22.2 No. 210.2. 
 
9.1.1A 
Class I Apparatus Leakage 
Add the following Clause: 
For cord-connected Class I apparatus, the 
leakage current through the safety earthing 
conductor expressed as voltages U1 and U2 shall 
not exceed U1 = 105V (peak) and U2 = 1.05V 
(peak) (1.5mA). 
 
N/A 
 
Apparatus having a leakage current between 0.75 
mA and 1.5 mA shall be provided with a caution 
label on the mains cord with the following, or 
equivalent: 
"CAUTION - TO REDUCE THE RISK OF 
ELECTRIC SHOCK, GROUNDING OF THE 
CENTRE PIN OF THIS PLUG MUST BE 
MAINTAINED". 
 
N/A 
Page 16 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
CA  Canada 
CA 
9.1.1.2 
Determination of accessible parts 
– loudspeaker 
enclosure parts 
Add the following after the fourth paragraph: 
Moving parts of loudspeaker systems, such as 
dust caps or cones of drivers or passive radiators 
are not regarded as preventing accessibility. 
NOTE 1A: See also Clause 13.3.1 
 
N/A 
9.2 
Removal of protective covers 
– loudspeaker 
grilles 
Add the following after the second paragraph: 
This requirement applies also to internal parts of 
loudspeaker systems that become accessible by 
removal of a loudspeaker grille from the outside 
either by hand or with the use of a tool, coin, or 
other object. In such cases, the apparatus shall 
be marked according to Clause 5.3A. 
Replace the third paragraph with the following: 
Compliance is checked by inspections and by 
application of the tests of Clause 9.1.1, except 
that the measurements are made 2s after 
removal of the cover or grille. 
 
N/A 
10.2A 
Enclosure type designation and use 
– outdoor 
enclosure 
Add the following clause: 
If equipment is installed in environments where 
the enclosure is required to prevent ingress of 
water or dust, the enclosure shall be classified as 
a type recognized by the Canadian Electrical 
Code, Part I, and shall comply with the 
requirements of CSA/CSA-C22.2 No. 94. 
 
N/A 
11.2 
Heating 
– flammable gases 
Add the following clause: 
Flammable gases shall not be emitted from a 
component for more than 10 secs. 
 
Page of 127