Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
1.1.1
Add the following paragraph and note:
This Standard applies to the safety of such
equipment designed to be installed and used in
accordance with the rules of the Canadian
Electrical Code (CEC), Part I.
equipment designed to be installed and used in
accordance with the rules of the Canadian
Electrical Code (CEC), Part I.
Note 4A: Manufacturers designing products for
use in Canada may find a helpful summary of the
equipment-related requirement of the CEC, Part
I, in CSA SPE-2000.
use in Canada may find a helpful summary of the
equipment-related requirement of the CEC, Part
I, in CSA SPE-2000.
P
1.2
Normative references
Where reference is made to CSA Publications,
such reference shall be considered to refer to the
latest edition and all amendments published to
that edition. This Standard refers to the following
Standards, and the years shown indicate the
latest editions available at the time of printing.
such reference shall be considered to refer to the
latest edition and all amendments published to
that edition. This Standard refers to the following
Standards, and the years shown indicate the
latest editions available at the time of printing.
ANSI/IEEE Standard
C62.1-1984, Surge Arresters for Alternating-
Current Power Circuits
Current Power Circuits
CSA Standards
C22.1-02, Canadian Electrical Code, Part 1
CAN/CSA-C22.2 No. 0-M91 (R2001), General
Requirements - Canadian Electrical Code, Part II
Requirements - Canadian Electrical Code, Part II
C22.2 No. 0.4-M1982 (R1999), Bonding and
Grounding of Electrical Equipment (Protective
Grounding)
Grounding of Electrical Equipment (Protective
Grounding)
C22.2 No. 0.15-01, Adhesive Labels
CAN/CSA-C22.2 No. 1-98, Audio, Video and
Similar Electronic Equipment
Similar Electronic Equipment
CAN/CSA-C22.2 No. 21-95 (R1999), Cord Sets
and Power Supply Cords
and Power Supply Cords
C22.2 No. 39-M1987 (R1999), Fuseholder
Assemblies
Assemblies
C22.2 No. 42-99, General Use Receptacles,
Attachment Plugs, and Similar Wiring Devices
Attachment Plugs, and Similar Wiring Devices
CAN/CSA-C22.2 No. 49-98, Flexible Cords and
Cables
Cables
CAN/CSA-C22.2 No. 94-M91 (R2001), Special
Purpose Enclosures
Purpose Enclosures
C22.2 No. 127-99, Equipment and Lead Wires
C22.2 No. 209-M1985 (R1999), Thermal Cut-Offs
CAN/CSA-C22.2 No. 210.2-M90 (R2001),
Appliance Wiring Material Products
Appliance Wiring Material Products
CAN/CSA-C22.2 No. 223-M91 (1999), Power
P
Page 14 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
Supplies with Extra-Low-Voltage Class 2 Outputs
CAN/CSA-C22.2 No. 228-92 (1999), Cathode
Ray Tubes
Ray Tubes
CAN/CSA-C22.2 No. 248.14-00, Low Voltage
Fuses - Part 14
Fuses - Part 14
Spe-2000-94, Guide for Electrical Equipment for
Installation and Use in Canada
Installation and Use in Canada
IEC Standards
60038:2002, IEC standard voltages
60083:1975, Plug and socket-outlets for domestic
and similar general use.
and similar general use.
60173:1964, Colours of the cores of flexible
cables and cords.
cables and cords.
60320 (all parts), Appliance couplers for
household and similar general purposes.
household and similar general purposes.
60707:1981, Methods of test for the
determination of the flammability of solid electrical
insulating materials.
determination of the flammability of solid electrical
insulating materials.
60884 (all parts), Plugs and socket-outlets for
household and similar purposes.
household and similar purposes.
60906-1:1986, IEC System of plugs and socket-
outlets for household and similar purposes - Part
1: Plugs and socket-outlets 16A 250V ac.
outlets for household and similar purposes - Part
1: Plugs and socket-outlets 16A 250V ac.
60906-2:1997, IEC System of plugs and socket-
outlets for household and similar purposes - Part
2: Plugs and socket-outlets 15A 125V ac.
outlets for household and similar purposes - Part
2: Plugs and socket-outlets 15A 125V ac.
60906-3:1994, IEC System of plugs and socket-
outlets for household and similar purposes - Part
3: SELV plugs and socket-outlets 16A 6V, 12V,
24V, 48V ac and dc.
outlets for household and similar purposes - Part
3: SELV plugs and socket-outlets 16A 6V, 12V,
24V, 48V ac and dc.
3.2A
Add the following clause:
A component power supply complying with
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
N/A
4.2.1
Add the following after the fifth paragraph:
For apparatus intended for use at nominal 120V
ac, the apparatus shall comply with this standard
at supply voltages between 108V and 125V. For
apparatus intended for use at nominal 240V ac
the apparatus shall comply with this standard at
supply voltages between 216V and 250V.
ac, the apparatus shall comply with this standard
at supply voltages between 108V and 125V. For
apparatus intended for use at nominal 240V ac
the apparatus shall comply with this standard at
supply voltages between 216V and 250V.
N/A
Page 15 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
4.2.10
Add the following after the second paragraph:
As an alternative, a supply apparatus for general
use complying with CSA/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
use complying with CSA/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
N/A
5
Markings and instructions
– adhesive nameplates
Add the following paragraph:
Adhesive nameplates on commercial products
shall comply with CSA C22.2 No 0.15.
shall comply with CSA C22.2 No 0.15.
P
5.1
Add the following item:
j) Date of manufacture: a date or code identifying
the period of manufacture shall be marked on the
apparatus;
the period of manufacture shall be marked on the
apparatus;
Manufactured May 2012
P
5.3A
Add the following clause:
Where a loudspeaker grille, removable from the
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:
"Caution - To prevent electric shock hazard,
replace grille."
replace grille."
Alternatively, the symbol in Clause 5.2 b) shall be
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
Compliance is checked by inspection.
N/A
8.9
Add the following title to this clause:
Mains Wiring
Add the following paragraph:
Wiring in circuits with voltages higher than 42V
peak shall comply with CSA C22.2 No 127 or
CAN/CSA C22.2 No. 210.2.
peak shall comply with CSA C22.2 No 127 or
CAN/CSA C22.2 No. 210.2.
P
9.1.1A
Class I Apparatus Leakage
Add the following Clause:
Add the following Clause:
For cord-connected Class I apparatus, the
leakage current through the safety earthing
conductor expressed as voltages U1 and U2 shall
not exceed U1 = 105V (peak) and U2 = 1.05V
(peak) (1.5mA).
leakage current through the safety earthing
conductor expressed as voltages U1 and U2 shall
not exceed U1 = 105V (peak) and U2 = 1.05V
(peak) (1.5mA).
N/A
Apparatus having a leakage current between 0.75
mA and 1.5 mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:
mA and 1.5 mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:
"CAUTION - TO REDUCE THE RISK OF
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
N/A
Page 16 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
9.1.1.2
Determination of accessible parts
– loudspeaker
enclosure parts
Add the following after the fourth paragraph:
Moving parts of loudspeaker systems, such as
dust caps or cones of drivers or passive radiators
are not regarded as preventing accessibility.
dust caps or cones of drivers or passive radiators
are not regarded as preventing accessibility.
NOTE 1A: See also Clause 13.3.1
N/A
9.2
Removal of protective covers
– loudspeaker
grilles
Add the following after the second paragraph:
This requirement applies also to internal parts of
loudspeaker systems that become accessible by
removal of a loudspeaker grille from the outside
either by hand or with the use of a tool, coin, or
other object. In such cases, the apparatus shall
be marked according to Clause 5.3A.
loudspeaker systems that become accessible by
removal of a loudspeaker grille from the outside
either by hand or with the use of a tool, coin, or
other object. In such cases, the apparatus shall
be marked according to Clause 5.3A.
Replace the third paragraph with the following:
Compliance is checked by inspections and by
application of the tests of Clause 9.1.1, except
that the measurements are made 2s after
removal of the cover or grille.
application of the tests of Clause 9.1.1, except
that the measurements are made 2s after
removal of the cover or grille.
N/A
10.2A
Enclosure type designation and use
– outdoor
enclosure
Add the following clause:
If equipment is installed in environments where
the enclosure is required to prevent ingress of
water or dust, the enclosure shall be classified as
a type recognized by the Canadian Electrical
Code, Part I, and shall comply with the
requirements of CSA/CSA-C22.2 No. 94.
the enclosure is required to prevent ingress of
water or dust, the enclosure shall be classified as
a type recognized by the Canadian Electrical
Code, Part I, and shall comply with the
requirements of CSA/CSA-C22.2 No. 94.
N/A
11.2
Heating
– flammable gases
Add the following clause:
Flammable gases shall not be emitted from a
component for more than 10 secs.
component for more than 10 secs.