Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
17.9A
17.9A.1
Adhesive securement and conductive coatings
Add the following clause:
Adhesive securement
The following parts, the displacement of which
may result in a fire or shock hazard, shall not be
secured solely by adhesive, unless the adhesive
system complies with the resistance to external
forces test of Clause 9.1.7, the bump test of
Clause 12.1.1, and the impact test of Clause
12.1.3, after conditioning in accordance with
Clause 17.9A.2:
may result in a fire or shock hazard, shall not be
secured solely by adhesive, unless the adhesive
system complies with the resistance to external
forces test of Clause 9.1.7, the bump test of
Clause 12.1.1, and the impact test of Clause
12.1.3, after conditioning in accordance with
Clause 17.9A.2:
a) internal metal parts/conductive coatings;
b) barriers; and
c) required enclosure parts.
b) barriers; and
c) required enclosure parts.
Note: Cathode ray tubes are excluded from this
test.
test.
N/A
17.9A.2
17.9A.2.1
Adhesive and conductive coating securement
conditioning
conditioning
General:
Where required by Clause 17.9A.1, one sample
of the apparatus or enclosure section shall be
conditioned in accordance with the requirements
of Clause 17.9A.2.2. Equivalent ageing test data
supplied by the manufacturer will be considered
in lieu of ageing.
of the apparatus or enclosure section shall be
conditioned in accordance with the requirements
of Clause 17.9A.2.2. Equivalent ageing test data
supplied by the manufacturer will be considered
in lieu of ageing.
N/A
Page 22 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
17.9A.2.2 Ageing
Day 1: Place in oven at 100 ± 1ºC for 1 week, or
82 ± 1ºC
82 ± 1ºC
for 8 weeks at the manufacturer‘s
option.
Day 8 or Day 57:
1. Remove from oven and leave at room
temperature for 1 h.
temperature for 1 h.
2. Place in freezer at
–35ºC for 2 h.
3. Remove from freezer and allow to reach room
temperature overnight.
temperature overnight.
Day 9 or Day 58:
1. Place in a compartment at 96% relative
humidity for 3 h.
humidity for 3 h.
2. Remove and leave at room temperature and
humidity for 1 h.
humidity for 1 h.
3. Place in over at a temperature selected in the
first cycle for 3 h.
first cycle for 3 h.
4. Remove and allow to come to room
temperature overnight.
temperature overnight.
Day 10 or Day 59:
1. Place in freezer at
–35ºC for 2 h.
2. Remove and leave at room temperature for 1
h.,
h.,
3. Place in humidity chamber at 96% relative
humidity for 3 h.
humidity for 3 h.
4. Remove and allow to come to room
temperature overnight.
temperature overnight.
Day 11 or Day 60:
1. Place in oven at the temperature selected in
the first cycle for 3 h.
the first cycle for 3 h.
2. Remove for 1 h.
3. Place in freezer at
–35ºC for 2 h.
4. Remove and allow to come to room
temperature overnight.
temperature overnight.
Day 12 or Day 61:
1. Place in humidity chamber at 96% relative
humidity for 3 h.
2. Remove and perform mechanical tests as
required by Clause 17.9A.1 as applicable.
humidity for 3 h.
2. Remove and perform mechanical tests as
required by Clause 17.9A.1 as applicable.
N/A
Page 23 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
18
18.1A
Mechanical strength of picture tubes and
protection against the effects of implosion
protection against the effects of implosion
(Cathode Ray Tubes)
Add the following clause:
Add the following clause:
A picture tube with a maximum face dimensions
exceeding 75mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
exceeding 75mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
N/A
19
Stability and Mechanical Hazards
Add the following after the second paragraph:
Add the following after the second paragraph:
The test of 19.3 is only required for:
Apparatus with a mass of 25 kg or more; or
Apparatus, excluding loudspeaker systems, with
a height of 1m or more; or
a height of 1m or more; or
Apparatus, including loudspeaker systems, in
combination with a supplied or recommended
cart of stand with a total height of 1m or more.
combination with a supplied or recommended
cart of stand with a total height of 1m or more.
N/A
Add the following paragraph:
Apparatus not tested because it is intended to be
fastened in place shall be provided with the
following warning, marked on the apparatus or on
a durable label attached to the mains cord:
fastened in place shall be provided with the
following warning, marked on the apparatus or on
a durable label attached to the mains cord:
―WARNING: This apparatus must be securely
attached to the floor /wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury / death‖
attached to the floor /wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury / death‖
N/A
20
20.2.1A
Fire enclosure
(Projector Lamp Enclosure)
Add the following clause:
Add the following clause:
Enclosures of apparatus containing high voltage
or projection lamps shall have a minimum
flammability rating of category FV1 according to
IEC 60707 at the minimum thickness used.
or projection lamps shall have a minimum
flammability rating of category FV1 according to
IEC 60707 at the minimum thickness used.
N/A
Annex B
Apparatus to be connected to the
telecommunications networks
telecommunications networks
Replace this annex with the following:
Apparatus intended for direct connection to a
TELECOMMUNICATION NETWORK shall
comply with:
a) Clause 19 of CSA C22.2 No 1; or
b) CAN/CSA C22.2 No. 60950.
TELECOMMUNICATION NETWORK shall
comply with:
a) Clause 19 of CSA C22.2 No 1; or
b) CAN/CSA C22.2 No. 60950.
N/A
Page 24 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CH Switzerland
CH
21
Ordinance on environmentally hazardous
substances SR 814.081, Annex 1.7,
substances SR 814.081, Annex 1.7,
Mercury - Annex 1.7 of SR 814.81 applies for
mercury.
mercury.
Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
Ordinance on chemical hazardous risk reduction
SR 814.81, Annex 2.15
SR 814.81, Annex 2.15
Batteries
Annex 2.15 of SR 814.81 applies for batteries
containing cadmium and mercury.
containing cadmium and mercury.
Note: Ordinance relating to environmentally
hazardous substances, SR 814.013 of 1986-06-
09 is not longer in force and superseded by SR
814.81 of 2009-02-01 (ChemRRV).
hazardous substances, SR 814.013 of 1986-06-
09 is not longer in force and superseded by SR
814.81 of 2009-02-01 (ChemRRV).
N/A
24
Supply cords of portable electrical appliances
having a rated current
having a rated current
not exceeding 10 A shall be provided with a plug
complying with IEC 60884-1(3.ed.) + am1, SEV
1011 and one of the following dimension sheets:
complying with IEC 60884-1(3.ed.) + am1, SEV
1011 and one of the following dimension sheets:
- SEV 6533-2:2009 Plug type 11, L + N, 250V
10A
10A
- SEV 6534-2:2009 Plug type 12, L + N + PE,
250V 10A
250V 10A
- SEV 6532-2:2009 Plug type 15, 3L + N + PE,
250/400V 10A
250/400V 10A
Supply cords of portable electrical appliances
having a rated current not exceeding 16 A shall
be provided with a plug complying with IEC
60884-1(3.ed.) + am1, SEV 1011 and one of the
following dimension sheets:
having a rated current not exceeding 16 A shall
be provided with a plug complying with IEC
60884-1(3.ed.) + am1, SEV 1011 and one of the
following dimension sheets:
- SEV 5933-2:2009 Plug type 21 L + N, 250 V,
16A
16A
- SEV 5934-2:2009 Plug type 23 L + N + PE, 250
V, 16A
V, 16A
- SEV 5932-2:2009 Plug type 25 3L + N + PE,
250/400V 16A
250/400V 16A
NOTE 16 A plugs are not often used in Swiss
domestic installation system.
domestic installation system.
N/A