Harman Kardon BDS 577 EMC - CB Certificate ▷ View online

Page 21 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
CA  Canada 
CA 
17.9A 
17.9A.1 
Adhesive securement and conductive coatings 
Add the following clause: 
Adhesive securement 
The following parts, the displacement of which 
may result in a fire or shock hazard, shall not be 
secured solely by adhesive, unless the adhesive 
system complies with the resistance to external 
forces test of Clause 9.1.7, the bump test of 
Clause 12.1.1, and the impact test of Clause 
12.1.3, after conditioning in accordance with 
Clause 17.9A.2: 
a)  internal metal parts/conductive coatings; 
b)  barriers; and 
c)  required enclosure parts. 
Note: Cathode ray tubes are excluded from this 
test. 
 
N/A 
17.9A.2 
17.9A.2.1 
Adhesive and conductive coating securement 
conditioning 
General:   
Where required by Clause 17.9A.1, one sample 
of the apparatus or enclosure section shall be 
conditioned in accordance with the requirements 
of Clause 17.9A.2.2.  Equivalent ageing test data 
supplied by the manufacturer will be considered 
in lieu of ageing. 
 
N/A 
Page 22 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
CA  Canada 
CA 
17.9A.2.2  Ageing 
Day 1:  Place in oven at 100 ± 1ºC for 1 week, or 
82 ± 1ºC 
for 8 weeks at the manufacturer‘s 
option. 
Day 8 or Day 57: 
1.  Remove from oven and leave at room 
temperature for 1 h. 
2.  Place in freezer at 
–35ºC for 2 h. 
3.  Remove from freezer and allow to reach room 
temperature overnight. 
Day 9 or Day 58: 
1.  Place in a compartment at 96% relative 
humidity for 3 h. 
2.  Remove and leave at room temperature and 
humidity for 1 h. 
3.  Place in over at a temperature selected in the 
first cycle for 3 h. 
4.  Remove and allow to come to room 
temperature overnight. 
Day 10 or Day 59: 
1.  Place in freezer at 
–35ºC for 2 h. 
2.  Remove and leave at room temperature for 1 
h., 
3.  Place in humidity chamber at 96% relative 
humidity for 3 h. 
4.  Remove and allow to come to room 
temperature overnight. 
Day 11 or Day 60: 
1.  Place in oven at the temperature selected in 
the first cycle for 3 h. 
2.  Remove for 1 h. 
3.  Place in freezer at 
–35ºC for 2 h. 
4.  Remove and allow to come to room 
temperature overnight. 
Day 12 or Day 61: 
1.  Place in humidity chamber at 96% relative 
humidity for 3 h. 
2.  Remove and perform mechanical tests as 
required by Clause 17.9A.1 as applicable. 
 
N/A 
Page 23 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
CA  Canada 
CA 
18 
18.1A 
 
 
Mechanical strength of picture tubes and 
protection against the effects of implosion 
(Cathode Ray Tubes) 
Add the following clause: 
A picture tube with a maximum face dimensions 
exceeding 75mm either shall be intrinsically 
protected with respect to effects of implosion and 
to mechanical impact, in accordance with 
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or 
the enclosure of the apparatus shall provide 
adequate protection against the effects of an 
implosion of the tube (see Clause 12). 
 
N/A 
19 
Stability and Mechanical Hazards  
Add the following after the second paragraph: 
The test of 19.3 is only required for: 
Apparatus with a mass of 25 kg or more; or 
Apparatus, excluding loudspeaker systems, with 
a height of 1m or more; or 
Apparatus, including loudspeaker systems, in 
combination with a supplied or recommended 
cart of stand with a total height of 1m or more. 
 
N/A 
 
Add the following paragraph: 
Apparatus not tested because it is intended to be 
fastened in place shall be provided with the 
following warning, marked on the apparatus or on 
a durable label attached to the mains cord: 
―WARNING: This apparatus must be securely 
attached to the floor /wall per installation 
instructions. Tipping, shaking, or rocking the 
machine may cause injury / death‖ 
 
N/A 
20 
20.2.1A 
Fire enclosure 
(Projector Lamp Enclosure) 
Add the following clause: 
Enclosures of apparatus containing high voltage 
or projection lamps shall have a minimum 
flammability rating of category FV1 according to 
IEC 60707 at the minimum thickness used. 
 
N/A 
Annex B 
 
Apparatus to be connected to the 
telecommunications networks 
Replace this annex with the following: 
Apparatus intended for direct connection to a 
TELECOMMUNICATION NETWORK shall 
comply with: 
a) Clause 19 of CSA C22.2 No 1; or 
b) CAN/CSA C22.2 No. 60950.  
 
N/A 
 
Page 24 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
 
CH  Switzerland 
CH 
21 
Ordinance on environmentally hazardous 
substances SR 814.081, Annex 1.7, 
Mercury - Annex 1.7 of SR 814.81 applies for 
mercury. 
Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Ordinance on chemical hazardous risk reduction 
SR 814.81, Annex 2.15 
Batteries 
Annex 2.15 of SR 814.81 applies for batteries 
containing cadmium and mercury. 
Note: Ordinance relating to environmentally 
hazardous substances, SR 814.013 of 1986-06-
09  is not longer in force and superseded by SR 
814.81 of 2009-02-01 (ChemRRV). 
 
N/A 
24 
Supply cords of portable electrical appliances 
having a rated current 
not exceeding 10 A shall be provided with a plug 
complying with  IEC 60884-1(3.ed.) + am1, SEV 
1011 and one of the following dimension sheets: 
- SEV 6533-2:2009 Plug type 11, L + N, 250V 
10A 
- SEV 6534-2:2009 Plug type 12, L + N + PE, 
250V 10A 
- SEV 6532-2:2009 Plug type 15, 3L + N + PE, 
250/400V 10A 
Supply cords of portable electrical appliances 
having a rated current not exceeding 16 A shall 
be provided with a plug complying with IEC 
60884-1(3.ed.) +  am1, SEV 1011 and one of the 
following dimension sheets: 
- SEV 5933-2:2009 Plug type 21 L + N, 250 V, 
16A 
- SEV 5934-2:2009 Plug type 23 L + N + PE, 250 
V, 16A 
- SEV 5932-2:2009 Plug type 25 3L + N + PE, 
250/400V 16A 
NOTE 16 A plugs are not often used in Swiss 
domestic installation system. 
 
N/A 
Page of 127
Display