Harman Kardon BDS 577 EMC - CB Certificate ▷ View online

Page 65 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
18.1 
All tubes shall be mounted such that the 
enclosure of the apparatus protects the tube 
against the effects of implosion. Delete reference 
to clause 18.2. 
 
N/A 
18.2, 
18.2.1, 
18.2.3 
deleted 
 
N/A 
19 
Add reference to 19.2.1. The test of 19.3 is 
conducted on 1) apparatus with direct view CRT 
with 48 cm diagonal min., 2) apparatus, other 
than a speaker, with a mass greater than 47 kg, 
and 3) apparatus, other than a speaker, with a 
mass or 25 kg or greater and a height of 1 m or 
more. The tests in 19.1, 19.2 and 19.3 shall not 
cause the apparatus to overturn. During the test 
of 19.2.1, the apparatus shall not slide. 
 
N/A 
19.2.1 
Add: Slide test requirements. 
 
N/A 
19.3 
Replace by Horizontal force stability test 
requirements. 
 
N/A 
Table 20  Add values for horizontal force test 
 
N/A 
19.6 
Add: ―or equipment rack mounting‖. 
 
N/A 
20.1a 
Delete 
 
N/A 
20.1b 
Replace ―IEC 60707‖ with ―UL 94‖ 
Add: ―-parts such as protection TV lenses, 
loudspeaker parts, external accessories, and 
fibrous materials less then 0.25 mm thick.‖ 
 
N/A 
20.1.2 
Revise text to read: ―Sleeving, extruded tubing 
and insulation on wiring shall be rated VW-1 
under following conditions: a) wiring located in a 
circuit that is considered a potential ignition 
source‖ or b) wiring not located in a circuit that is 
a potential ignition source but is in contact with 
wiring located in a circuit that is a potential 
ignition source. ‖Tape should be flame retardant.‖ 
Delete Note and add: ―Tape in contact with parts 
of circuits that are potential ignition sources shall 
be flame retardant. 
 
Page 66 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
20.1.3 
Replace 1st paragraph with: ―Base material of 
printed wiring boards, on which the available 
power as the connection exceeds 15 W or the 
operating voltage exceeds 50 V a.c. or d.c under 
normal operating conditions, shall be of 
flammability category V-1 or better according to 
UL 94.‖ 
In 2nd paragraph replace ―IEC 60707‖ with ―UL 
94‖ and remove exception for printed boards 
housed in metal enclosures. 
In 3rd paragraph replace ―IEC 60707‖ with ―UL 
94‖ and delete option to use Clause G.1 of Annex 
G. 
 
20.1.4 
Replace with: ―Components and parts shall 
comply with the relevant flammability category 
according to UL 94 as specified in Table 21. 
Delete all other text. 
Add: ―Component power supplies complying with 
the construction and test requirements of UL 
1310, UL 1950 Third Edition, or UL 60950 are 
considered to fulfill the test requirements on the 
clause.‖ 
Table 21 - Replace complete table with new table 
for ―Flammability categories for components and 
parts.‖ 
 
20.2.1 
Modification: 1st paragraph: ―Fire enclosure 
required for 1) circuits and components where the 
available power exceeds 15 W, 2) inductors and 
windings conductively connected to the mains 
and 3) high-voltage products. The fire enclosure 
shall comply with the flammability requirements of 
Table 22 according to UL 94 and 746C. 2nd, 3rd, 
and 4th paragraphs are deleted. 
In 5th paragraph replace ―IEC 60707 or clause 
G.1 of Annex G‖ with ―UL 94 or UL 746C.‖ 
Table 22 
– Add‖ Flammability categories for fire 
enclosures. 
 
20.2.2 
Revise text to read: ―Internal fire enclosures shall 
not have openings that permit accessibility to 
components, wiring, connections, or printed 
wiring board conductive patterns where the 
available power exceeds 15 W and to inductors 
and windings conductively connected to the 
mains and shall comply with the material 
requirements in Table 22. Compliance is checked 
by inspection and measurement and using the 
jointed test finger.‖ 
 
N/A 
20.2.3 
Modification: Outer enclosures shall have a 
minimum flammability rating of HB, per UL 94, 
when an internal fire enclosure is provided. 
 
N/A 
Page 67 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
Figures 
Modifications to Figures: 
Fig 14 - Illustrates the articulated finger probe. 
Fig 15 - Illustrates the shock hazard marking and 
associated graphical symbols. 
Fig 16 - Illustrates the shock hazard graphical 
symbol. 
Fig 17 - Illustrates portable cart marking. 
Fig 18 - High voltage spacings graph. 
Fig 19 - Class 105 insulation aging temperature 
graph. 
Fig 20 - Flowchart for horizontal force test. 
 
Annex A 
Modification: Apparatus intended for outdoor use 
or wet locations has any of the following 
attributes: a) provided with a means to make it 
transportable, b) has a mass less than 35 kg, c) 
can be battery operated, d) associated literature 
states or implies such use 
 
N/A 
 
Add: Apparatus in a), b), or c) above is not 
considered for outdoor use or in wet locations if 
marked as specified in 5.4.  
 
N/A 
A.5, 
A.5.1, 
A.5.4.1 
deleted. 
 
N/A 
A.9.1.1 
Add: Touch current test shall be conducted after 
the water spray test described in A.11.1.1 and the 
touch current shall not be more than 0.5 MIU 
when the open-circuit potential between any 
accessible part and earth or any other accessible 
part is more than 21.2 V peak. 
 
N/A 
A.10, 
A10.2, 
A.10.2.1, 
A.10.2.2 
Deleted 
 
N/A 
A.11.1.1 
Add: Apparatus shall be subjected to the water 
spray test according to UL 1571. 
 
N/A 
A.16.1 
Add: Flexible cords shall be suitable for outdoor 
use. 
 
N/A 
A.20.2.1 
Add: Enclosures for an apparatus intended for 
permanent outdoor location shall comply with 
requirements for Type 3 enclosures in UL 50. 
 
N/A 
Annex B 
 
5th paragraph - add reference to clause 4.2.1.1 in 
IEC 62151. 
Add to 12th paragraph: ―The requirements of 
4.2.1.1 shall be replaced by the requirements or 
2.3.1 of UL 60950, Third Edition.‖ 
 
N/A 
Page 68 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
 
13th paragraph, 2nd dash replace with: ―In the 
event of a single insulation fault, the voltages on 
the TNV-0 circuits, TNV-1 circuits and accessible 
conductive parts shall not exceed the values 
given in clause 9.1.1.1a of this standard for more 
than 0.2 s. Moreover, the limits values as given in 
11.1 shall not be exceeded. After 0.2 s the 
voltage limits of 4.1.2 (35 V peak, or 60 V d.c.) 
shall apply.‖ 
 
N/A 
 
Add to 19th paragraph: ―Apparatus intended to be 
connected to telecommunication networks and 
having ringing voltages applied to the apparatus 
is subjected to touch current limits in accordance 
with clause 5.1.8.1.1 of UL 60950, Third Edition‖  
 
N/A 
 
Add to 21st paragraph: ―Telecommunication 
network that uses outside cable shall comply with 
the requirements for protection against 
overvoltage from power line crosses per 6.4 of 
UL 60950, Third Edition‖ 
 
N/A 
 
Add to 22nd paragraph: ―Acoustic tests per 6.5 of 
UL 60950, Third Edition for apparatus containing 
earphone held against the ear.‖ 
 
N/A 
 
Add to 24th par
agraph: ―Apparatus shall be 
provided with appropriate markings and 
instructions as described in Annex NAA of UL 
60950, Third Edition.‖ 
 
N/A 
Annex D  Figure D.1 & Note delete reference to IEC 60990 
and add reference to ANSI C101. Add touch 
current value in MIU where MIU = U2 x 2 (r.m.s. 
value) 
 
Annex G  Deleted 
 
 
N/A 
Annex Q  Add: Safety requirements for video apparatus for 
use in health care facilities 
 
N/A 
Annex R  Add: Safety requirements for undercabinet 
apparatus 
 
N/A 
Annex S 
Add: Safety requirements for in-wall mounted 
apparatus 
 
N/A 
Annex T 
Add: Safety requirements for apparatus with 
projection lamps 
 
N/A 
Annex U  Add: Safety requirements for permanently 
connected apparatus 
 
N/A 
Annex V 
Add: Safety requirements for carts, stands, and 
similar apparatus for use with specific apparatus 
covered by this standard 
 
N/A 
Annex W  Add: Construction details for a 0.02-ohm shunt 
for use in the peak inrush-current measurement 
described in 14.6.11.1 
 