Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
 
MY  Malaysia 
MY 
 
Energy Commission circular no.1 year 2003 
(no.1/2003) 
States that a Certificate of Approval is required 
for manufacturing, selling, Advertising, displaying 
or importing into Malaysia, electrical/electronic 
products Listed in Annex A. 
- The supply voltage in Malaysia is 240 Vac, at 
50Hz. 
- Class 0 and 01 appliances are not allowed  
- 13A fused plug-tops shall comply to Malaysian 
standard (MS 589:Part1:1997), if applicable. 
- 2-pin plug tops shall comply to Malaysian 
standard (MS 1578:2003) if applicable. 
 
 
 
NO  Norway 
NO 
13.3.1 
To the second paragraph the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification: 
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 
Page 50 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
NO  Norway 
NO 
15.1.1 
Mains socket-outlets mounted on CLASS II apparatus shall comply with the 
specifications given in CEE Publ. 7 as fas as applicable, with the following amendments: 
§ 8 Dimensions 
a 2,5 A 250 V two-pole socket-outlets for electronic apparatus shall comply with the 
enclosed Standard Sheet I. 
 
§ 24 Mechanical strength 
a 2,5 A, 250 V socket-outlets for CLASS II electronic apparatus are tested as specified 
in 12.1.3 of EN 60065. 
Also the protecting rim shall be tested. 
Justification: 
Act of 24 May 1929 relating to supervision of electrical installation (TEA 1929/FEL 1998). 
N/A 
J2 
After Table J.1 the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification: 
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 
Page 51 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
NO  Norway 
NO 
Annex B  Replace NOTE 1 by 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 
62151). 
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph: 
NOTE - In Norway, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet. 
The marking text shall be as follows: 
"Apparatet skal tilkoples jordet stikkontakt" 
 
N/A 
Page 52 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
NO  Norway 
NO 
5.3.1 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text 
is identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the test 
voltage of 1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of the test see N.2.1). 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the 
following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 testing, 
is tested with an Impulse test of 2.5kV defined in 
IEC 62151, subclause 6.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-
14; 
 
N/A 