Harman Kardon BDS 577 EMC - CB Certificate ▷ View online
Page 37 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
9.1.1.1
Addition:
In the last paragraph, add the following sentence
after the first sentence.
after the first sentence.
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0
mA.
CURRENT to earth shall not be more than 1.0
mA.
Class II equipment
N/A
10
Replacement:
In NOTE, r
eplace ―IEC 60664-1 and IEC 60664-4
[9]‖ by ―JIS C 0664:2003 and IEC/TR3 60664-4
[8]‖
[8]‖
P
10.1
Addition:
Add ―CLASS 0I EQUIPMENT and‖ to the head of
the first paragraph.
the first paragraph.
Class II equipment
N/A
10.3.2
Addition:
In Table 5, add the following values to the sub-
table of NOTE.
table of NOTE.
P
P
11.2.1
Addition:
Add the following after the original NOTE.
NOTE 2 Fuses except for the ones according to
IEC 60127 shall be tested in consideration of the
characteristic.
IEC 60127 shall be tested in consideration of the
characteristic.
P
11.2.3
Addition:
Add ―and CLASS 0I‖ after the words, CLASS I.
Add ―and CLASS 0I‖ after the words, CLASS I.
Class II equipment
N/A
13.4
Replacement:
In NOTE 2 of Table 11, replace
―IEC 60664-1‖ by
―JIS C 0664:2003‖ (corresponding to IEC 60664-
1).
1).
P
14.3.3.2
Addition:
In the second sentence of the first paragraph,
add
add
―or JIS C 2107, JIS C 2336 and JIS C 2338‖
after the reference, IEC 60454.
P
14.5.1.1
Addition:
In item a), add ―JIS C 9730 series or‖ before the
reference, IEC 60730 series.
reference, IEC 60730 series.
N/A
Page 38 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
14.5.1.2
Replacement:
In the first sentence of item a), replace
―IEC
60691
‖ by ―IEC 60691, JIS C 6691:2003 or
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the
Electrical Appliance and Material
stipulating technical requirements for the
Electrical Appliance and Material
‖.
N/A
Replacement:
After the second sentence of item a), replace
―IEC 60691‖ by ―JIS C 6691:2003 or IEC 60691‖.
―IEC 60691‖ by ―JIS C 6691:2003 or IEC 60691‖.
N/A
14.5.2.1
Replacement:
Replace the first and the second sentence as
follows:
follows:
Fuse-links, DIRECTLY CONNECTED TO THE
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
- the relevant part of IEC 60127 or JIS C 6575,
unless they have a rated current outside the
range specified in that standard. In the latter
case, they shall comply with the relevant part of
IEC 60127 or JIS C 6575 as far as applicable, or
range specified in that standard. In the latter
case, they shall comply with the relevant part of
IEC 60127 or JIS C 6575 as far as applicable, or
- Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the
Electrical Appliance and Material (limited to
Fuses with the rated current of 1 A or more).
Electrical Appliance and Material (limited to
Fuses with the rated current of 1 A or more).
P
14.5.2.2
Addition:
Add the following sentence before the last
paragraph.
paragraph.
For fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
P
14.5.3
Replacement:
Replace
―IEC 60730-1‖ by ―JIS C 9730-1‖
(corresponding to IEC 60730-1).
N/A
14.5.4
Replacement:
Replace
―IEC 60127‖ by ―IEC 60127 or JIS C
6575 ‖.
N/A
Page 39 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
14.6.1
Addition:
Add the following paragraph after NOTE.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
or d.c.
- the voltage across the open switch contacts
exceeds 35 Vpeak ac or 24 Vdc.
N/A
14.6.1
Replacement:
In item a), replace
―IEC 61058-1‖ by ―IEC 61058-
1 or JIS C 4526-1:199
9‖.
N/A
14.6.2
Replacement:
Replace
―IEC 61058-1‖ by ―IEC 61058-1 or JIS C
4526-
1:1999‖.
N/A
14.6.3
Replacement:
Replace
―IEC 61058-1‖ by ― IEC 61058-1 or JIS C
4526-
1:1999‖.
N/A
14.6.5
Replacement:
Replace
―IEC 61058-1‖ by ― IEC 61058-1 or JIS C
4526-
1:1999‖.
N/A
14.7
Replacement:
Replace
―IEC 60950‖ by ―JIS C 6950:2006‖.
N/A
Page 40 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
15.1.1
Replacement:
Replace the first and second paragraph by the
following.
following.
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
relevant JIS standards for plugs, socket-outlets,
appliance couplers or interconnection couplers. If
there is no appropriate JIS standard, they shall
comply with the relevant IEC standards.
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
relevant JIS standards for plugs, socket-outlets,
appliance couplers or interconnection couplers. If
there is no appropriate JIS standard, they shall
comply with the relevant IEC standards.
Appliance connectors, interconnection outlets and
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating
technical
requirements
for
the
Electrical Appliance and Material are accepted. In
that case, if due to the shape the contact parts
are connectable to those specified in standard
sheets of IEC 60320-1, they shall comply with
dimensions and ratings specified in the relevant
standard sheets of IEC 60320-1.
that case, if due to the shape the contact parts
are connectable to those specified in standard
sheets of IEC 60320-1, they shall comply with
dimensions and ratings specified in the relevant
standard sheets of IEC 60320-1.
Examples
of
relevant
specifications
and
standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
the
Ministerial
Ordinance
on
stipulating
technical requirements for the Electrical
Appliance. Article 2 (corresponding to IEC
60884) of the Ordinance.
Appliance. Article 2 (corresponding to IEC
60884) of the Ordinance.
- Appliance couplers: Appendix 4 of Article 1 of
the
Ministerial
Ordinance
on
stipulating
technical requirements for the Electrical
Appliance. Article 2 (corresponding to IEC
60320-1) of the Ordinance.
Appliance. Article 2 (corresponding to IEC
60320-1) of the Ordinance.
- Appliance inlets: IEC 60320-1
- Appliance outlets: Appendix 4 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. IEC
60320-2-2.
requirements for the Electrical Appliance. IEC
60320-2-2.
- Plug connectors: Appendix 4 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance.
requirements for the Electrical Appliance.
Delete NOTE 1 and NOTE 2.
Should be evaluated during
national approval
national approval
N/A
Click on the first or last page to see other BDS 577 service manuals if exist.