Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
12.3A.1
Television Impact Test: For television sets and
similar apparatus using a cathode ray tube larger
than 160mm diagonally, the top, sides, front and
rear of the enclosure, including the safety screen
where provided, shall be capable of withstanding
a single impact of 7J in accordance with Clause
12.3A.2 without developing any opening larger
than 130mm2 in the enclosure of the cathode ray
tube unless the minor dimension of any opening
is not more than 7mm.
similar apparatus using a cathode ray tube larger
than 160mm diagonally, the top, sides, front and
rear of the enclosure, including the safety screen
where provided, shall be capable of withstanding
a single impact of 7J in accordance with Clause
12.3A.2 without developing any opening larger
than 130mm2 in the enclosure of the cathode ray
tube unless the minor dimension of any opening
is not more than 7mm.
When applied to a safety screen, the impact shall
neither result in damage to its mounting to the
extent it is mechanically unsuitable for reuse nor
shall tempered glass, if used, be cracked.
neither result in damage to its mounting to the
extent it is mechanically unsuitable for reuse nor
shall tempered glass, if used, be cracked.
When applied to the face of a directly viewed
cathode ray tube, the impact shall not develop
any opening in the face of the tube. Scaling and
cracking of the glass is permissible. A cathode
ray tube that has been shown to comply with
CAN/CSA-C22.2 No 228 or CAN/CSA-E61965
shall be considered acceptable with no further
tests.
cathode ray tube, the impact shall not develop
any opening in the face of the tube. Scaling and
cracking of the glass is permissible. A cathode
ray tube that has been shown to comply with
CAN/CSA-C22.2 No 228 or CAN/CSA-E61965
shall be considered acceptable with no further
tests.
N/A
12.3A.2
Television Impact Object:
The impact specified in Clause 12.3A.1 shall be
caused by allowing a solid, smooth, steel sphere
51mm in diameter and weighing approximately
0.5kg to strike the enclosure with the specified
impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the
enclosure shall be tested with the proper cathode
ray tube mounted.
caused by allowing a solid, smooth, steel sphere
51mm in diameter and weighing approximately
0.5kg to strike the enclosure with the specified
impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the
enclosure shall be tested with the proper cathode
ray tube mounted.
N/A
13.3.1
General
– loudspeaker voice coil
Add the following after the third paragraph:
CLEARANCES between a loudspeaker voice coil
and adjacent conductive parts shall be
disregarded.
and adjacent conductive parts shall be
disregarded.
N/A
14.2.1
(Y-Capacitors)
Add the following paragraph:
Add the following paragraph:
As an alternative an isolating capacitor complying
with applicable requirements of CSA C22.2 No 1,
shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
with applicable requirements of CSA C22.2 No 1,
shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
CY501, CY502, CY504, CY506
P
14.2.2
(X-Capacitors)
Add the following paragraph:
Add the following paragraph:
As an alternative an across-line capacitor
complying with applicable requirements of CSA
C22.2 No 1, shall be acceptable.
complying with applicable requirements of CSA
C22.2 No 1, shall be acceptable.
CX501, CX502
P
Page 18 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
14.5.1.2
Thermal releases
Add the following paragraph:
Add the following paragraph:
As an alternative a THERMAL LINK complying
with CSA C22.2 No 209 shall be acceptable.
with CSA C22.2 No 209 shall be acceptable.
N/A
14.5.2
14.5.2.1
Fuse-links and fuse holders
Add the following paragraph:
As an alternative, a fuse-link complying with CSA
C22.2 No 248.14 shall be acceptable.
C22.2 No 248.14 shall be acceptable.
P
14.5.2.4
Add the following paragraph:
As an alternative a Fuseholder Assembly
complying with CSA C22.2 No 39 shall be
acceptable.
complying with CSA C22.2 No 39 shall be
acceptable.
N/A
14.6.1 to
14.6.5
14.6.5
Switches:
Add the following to each of the Clauses:
As an alternative, a TV-Rated Switch complying
with CSA C22.2 No 1-98, Cl 9 shall be
acceptable.
with CSA C22.2 No 1-98, Cl 9 shall be
acceptable.
P
14.11
Optocouplers
Add the following paragraph:
Add the following paragraph:
As an alternative, an optocoupler complying with
CSA C22.2 No. 1 shall be acceptable.
CSA C22.2 No. 1 shall be acceptable.
P
14.12
Surge suppression varistors
Add the following paragraph:
Add the following paragraph:
As an alternative, a varistor complying with CSA
C22.2 No. 1 shall be acceptable.
C22.2 No. 1 shall be acceptable.
P
14.12A
Gas discharge tubes
Add New Clause 14.12A:
Add New Clause 14.12A:
Gas discharge tubes complying with the following
tests may be connected to bridge BASIC or
REINFORCED INSULATION.
tests may be connected to bridge BASIC or
REINFORCED INSULATION.
Ten samples of gas discharge tubes isolating the
ac supply from exposed parts shall be subjected
to the varistor pulse tests of Clause 14.12.
Following the pulses, the device shall be allowed
to return to room temperature. The dielectric
breakdown voltage of the gas tube shall not
decrease by more than 50% and the gas
discharge tube shall comply with the electric
strength test of Clause 10.3, with the test voltage
reduced to twice the mains voltage.
ac supply from exposed parts shall be subjected
to the varistor pulse tests of Clause 14.12.
Following the pulses, the device shall be allowed
to return to room temperature. The dielectric
breakdown voltage of the gas tube shall not
decrease by more than 50% and the gas
discharge tube shall comply with the electric
strength test of Clause 10.3, with the test voltage
reduced to twice the mains voltage.
N/A
Page 19 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
15.1
15.1.1
Plugs and sockets
(Convenience Receptacle Type)
Add the Following Clause:
Add the Following Clause:
A receptacle provided for general purpose mains
output shall comply with the requirements of CSA
Standard C22.2 No 42 (dimensional requirements
are also specified in IEC 60906-2). The
attachment plug cap shall be polarized type when
the apparatus is provided with a manually
operated, MAINS connected single pole switch
for apparatus on-off operation, a socket
screwshell lampholder, or a 15 or 20 A socket
outlet.
output shall comply with the requirements of CSA
Standard C22.2 No 42 (dimensional requirements
are also specified in IEC 60906-2). The
attachment plug cap shall be polarized type when
the apparatus is provided with a manually
operated, MAINS connected single pole switch
for apparatus on-off operation, a socket
screwshell lampholder, or a 15 or 20 A socket
outlet.
P
15.1.2
(Audio Terminals)
Add the following paragraph:
Add the following paragraph:
Banana plugs shall be acceptable.
N/A
15.1.3
Adapter output connectors
Replace the first paragraph with the following:
Replace the first paragraph with the following:
Terminals and connectors used in output circuits
of supply apparatus, whose output is not a
standard nominal mains voltage according to IEC
60038, Table 1, shall not be compatible with
those specified for household and similar general
purposes, for example those described in IEC
60083[1], IEC 60320, IEC 60884, IEC 60906
(parts 1, 2, and 3), and CSA C22.2 No 42.
of supply apparatus, whose output is not a
standard nominal mains voltage according to IEC
60038, Table 1, shall not be compatible with
those specified for household and similar general
purposes, for example those described in IEC
60083[1], IEC 60320, IEC 60884, IEC 60906
(parts 1, 2, and 3), and CSA C22.2 No 42.
N/A
15.2
Provisions for protective earthing - Bond
Impedance
Impedance
Replace the third paragraph with the following:
Earthing connections shall comply with the test
requirements of CSA C22.2 No 0.4.
requirements of CSA C22.2 No 0.4.
N/A
15.3
15.3.1A
Terminals for external flexible cords and
permanent connections to the mains supply
permanent connections to the mains supply
(Permanent Wiring)
Add the following clauses:
Add the following clauses:
Equipment intended for permanent connection to
the mains shall have provisions for connection to
the wiring system in accordance with the
Canadian Electrical Code, Part I.
the mains shall have provisions for connection to
the wiring system in accordance with the
Canadian Electrical Code, Part I.
N/A
The terminal parts and all other provisions for
permanent connection to fixed wiring shall comply
with CSA Standard CAN/CSA-C22.2 No 0.
permanent connection to fixed wiring shall comply
with CSA Standard CAN/CSA-C22.2 No 0.
N/A
Page 20 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
CA Canada
CA
15.4.2
(Mains Plugs
– Type)
Add the following paragraphs:
Mains plugs of non-permanently installed
equipment shall comply with:
equipment shall comply with:
a) CSA C22.2 No 21 for moulded-on type
attachment plugs; and
attachment plugs; and
b) CSA C22.2 No 42 for disassembly type
attachment plugs (dimensional requirements are
also specified in IEC 60906-2).
attachment plugs (dimensional requirements are
also specified in IEC 60906-2).
N/A
Class II equipment provided with a general
purpose mains outlet, or lampholder, shall be
provided with a polarized-type plug.
purpose mains outlet, or lampholder, shall be
provided with a polarized-type plug.
N/A
If the plug is a polarized type, single pole
switches or over current protectors shall not be
connected in the identified conductor.
switches or over current protectors shall not be
connected in the identified conductor.
N/A
16
16.1
External flexible cords
Replace this clause with the following:
Flexible cord used for mains supply shall comply
with the requirements of CSA C22.2 No 49. The
cord type shall be in accordance with Table 4 of
CSA C22.2 No 1.
with the requirements of CSA C22.2 No 49. The
cord type shall be in accordance with Table 4 of
CSA C22.2 No 1.
The attachment plug shall be rated not less than
125% of the apparatus rated current.
125% of the apparatus rated current.
Cord sets shall comply with the requirements of
CSA C22.2 No 21.
CSA C22.2 No 21.
Non-detachable flexible cables and cords of
Class I apparatus shall be provided with a
green/yellow core connected to the protective
earthing terminal of the apparatus and, if a plug is
provided, to the protective earthing contact of the
plug.
Class I apparatus shall be provided with a
green/yellow core connected to the protective
earthing terminal of the apparatus and, if a plug is
provided, to the protective earthing contact of the
plug.
Compliance is checked by inspection.
Note: The colour of cores of flexible mains cords
is contained in IEC 60173[4].
is contained in IEC 60173[4].
Approved power cord used
P