Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
AU  Australia 
AU 
20.201.2.
Testing of insulated parts  
Part of insulating material supporting potential ignition sources shall be subject to the 
glow-wire test of AS/NZS 64695.2.11 which shall be carried out at 750°C. 
The test shall be also carried out on other parts of insulating material which are within a 
distance of 3 mm of the connection 
NOTE 
– Contacts in components such as switch contacts are considered to be 
connections. 
For parts which withstand the glow-wire test but produce a flame, other parts above the 
connection within the envelope of a vertical cylinder having a diameter of 20 mm and a 
height of 50 mm shall be subjected to the needle-flame test. However, parts shielded by 
a barrier which meets the needle-flame test need not be tested. 
The needle-flame test shall be made in accordance with AS/NZS 4695.2.2 with the 
following modifications: 
Clause of AS/NZS 4695.2.2 
Change 
5   Severities 
Replace with: 
The duration of application of the test flame shall be 
30 s 
1 s. 
8   Test procedure 
8.2 
 
 
 
8.4 
Replace the first sentence with: 
The specimen shall be arranged so that the flame can 
be applied to a vertical or horizontal edge as shown in 
the examples of figure 1. 
The first paragraph does not apply. 
Addition: 
If possible, the flame shall be applied at least 10 mm 
from a corner. 
8.5 
Replace with: 
The test shall be made on one specimen. If the 
specimen does not withstand the test, the test may be 
repeated on two further specimens, both of which 
shall then withstand the test 
10   Evaluation of test 
results 
Replace with: 
The duration of burning (tb) shall not exceed 30 s. 
However, for printed circuit boards, it shall not exceed 
15 s. 
The needle-flame test shall not be carried out on parts of material classified as V-0 or V-
1 according to AS/NZS 60695.11.10 provided that the sample tested was not thicker 
than the relevant part. 
N/A 
Page 10 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
AU  Australia 
AU 
20.201.2.
Testing by needle-flame test 
If parts, other than enclosures, do not withstand 
the glow wire tests of 20.201.2.2, by failure to 
extinguish within 30 s after the removal of the 
glow-wire tip, the needle-flame test detailed in 
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 
50 mm or which are likely to be impinged upon by 
flame during the tests of 20.201.2.2. Parts 
shielded by a separate barrier which meets the 
needle-flame test shall not be tested. 
NOTE 1 
– If the enclosure does not withstand the 
glow-wire test the appliance is considered to have 
failed to meet the requirements of Clause 21.201 
without the need for consequential testing. 
NOTE 2 
– If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if 
this indicates that burning or glowing particles can 
fall onto an external surface underneath the 
apparatus, the apparatus is considered to have 
failed to meet the requirements of Clause 21.201 
without the need for consequential testing 
NOTE 3 
– Parts likely to be impinged upon by the 
flame are considered to be those within the 
envelope of a vertical cylinder having a radius of 
10 mm and a height equal to the height of the 
flame, positioned above the point of the material 
supporting, in contact with, or in close proximity to, 
connections. 
 
N/A 
Page 11 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
AU  Australia 
AU 
20.201.2.
Testing of printed boards 
The base material of printed boards shall be 
subject to the needle-flame test of 
Clause 21.201.2.3. The flame shall be applied to 
the edge of the board where the heatsink effect is 
lowest when the board is positioned as in normal 
use. The flame shall not be applied to an edge 
consisting of broken perforations, unless the edge 
is less than 3 mm from a potential ignition source. 
The test is not carried out if the
— 
- printed board does not carry any potential 
ignition source; 
- base material of printed boards, on which the 
available power at a connection exceeds 15 VA 
operating at a voltage exceeding 50 V and equal 
or less than 400 V (peak) a.c. or d.c. under normal 
operating conditions, is of flammability category V-
1 or better according to AS/NZS 60695.11.10, or 
the printed boards are protected by an enclosure 
meeting the flammability category V-0 according 
to AS/NZS 60695.11.10, or made of metal, having 
openings only for connecting wires which fill the 
openings completely; or 
- base material of printed boards, on which the 
available power at a connection exceeds 15 VA 
operating at a voltage exceeding 400 V (peak) a.c. 
or d.c. under normal operating conditions, and 
base material of printed boards supporting spark 
gaps which provides protection against 
overvoltages, is of flammability category V-0 
according to AS/NZS 60695.11.10 or the printed 
boards are contained in a metal enclosure, having 
openings only for connecting wires which fill the 
openings completely. 
Compliance shall be determined using the 
smallest thickness of the material. 
NOTE 
– Available power is the maximum power 
which can be drawn from the supplying circuit 
through a resistive load whose value is chosen to 
maximize the power for more than 2 min when the 
circuit supplied is disconnected. 
 
N/A 
20.201.3  For open circuit voltages greater than 4 kV 
Potential ignition sources with open circuit 
voltages exceeding 4 kV (peak) a.c. or d.c. under 
normal operating conditions shall be contained in 
a fire enclosure which shall comply with 
flammability category V-1 or better according to 
AS/NZS 60695.11.10. 
 
N/A 
Page 12 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
AU  Australia 
AU 
Annex B 
After the heading add: 
For Australia only, this Annex is replaced by the 
requirements of the Telecommunications 
Labelling Notice issued under the 
Telecommunications Act. 
NOTE 
– The Telecommunications Act is 
administered by the Australian Communications 
Authority. 
 
N/A 