Harman Kardon BDS 577 EMC - CB Certificate ▷ View online

 
Page 11 of 18 
 
Report No.: 211-2012016-000 
Attachment No. 1
 
 
IEC60065K - ATTACHMENT 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
Z1 
(A11:2008) 
 
Add the following new clause after Clause 20: 
Z1 Resistance to candle flame ignition 
A television set shall be so designed that the 
likelihood of ignition and the spread of fire caused 
by a candle flame is reduced. 
NOTE 1 An apparatus with a viewing screen is not 
regarded to be a television set if it is declared not to 
be so by the manufacturer. 
This requirement does not apply to the display 
screen of rear projection TV’s. 
NOTE 2 This exemption has been allowed because 
this technology is falling out of use and it is 
expected that within a few years it will no longer 
exist. This exemption will not be extended to other 
technologies. 
NOTE 3 The frame around the screen is not 
exempted from the requirements. 
Wood and WOOD-BASED MATERIAL with a 
thickness of at least 6 mm is considered to fulfil the 
V-1 requirement when applying CLC/TS 62441. 
Compliance is checked according to CLC/TS 
62441. 
NOTE 4 The term vertical, as used in the first dash 
of clause 5.2 of CLC/TS 62441, does not mean a 
perfectly vertical position. It should be interpreted 
as any surface that can be touched by the flame of 
a candle of 150 mm height and 20mm diameter 
while the candle is still touching the supporting 
surface. A typical candle used in the home is 
assumed to be 20 mm diameter. 
NOTE 5 It is expected that CLC/TS 62441 will in 
the future be replaced by a standard, at which time 
that standard will become applicable, subject to a 
vote by National Committees at the time. 
 
N/A 
 
 
 
 
 
 
 
 
 
General 
13.3.1 
Delete note 4. 
14  
Delete note 4 and note 5. 
15.1.1 
Delete notes 1 and 2. 
15.2 
Delete note 2. 
16.1 
Delete note 1. 
16.2 
Delete the note. 
20 
Delete note 2. 
Annex B  
Replace note 1 by: In the CENELEC countries listed in IEC 62151, 
 
special national conditions apply. 
Annex G  
Delete the note. 
Annex J.2 
Delete the notes of Table J.1. 
Annex N  
Add after the introduction: For ROUTINE TEST reference is made to 
 
EN 50333. (Replaced by EN 50514) 
 
Page 12 of 18 
 
Report No.: 211-2012016-000 
Attachment No. 1
 
 
IEC60065K - ATTACHMENT 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
General 
(A2:2010) 
In IEC 60065:2001/A2 
Delete 
all the “country” notes according to the following list: 
5.3  
Note 
5.4.1   Note 
20  
Note 
For special national conditions, see Annex ZB. 
Bibliography  Additional EN standards. 
 
ZA 
Normative references to international publications 
with their corresponding European publications 
-- 
 
ZB 
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN) 
 
2.6.1 
 
DK: The following is added
Certain types of CLASS I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Justification: Heavy Current Regulations, Section 
107. 
 
N/A 
3.Z1 
(A2:2010) 
Denmark 
Add to the end of the subclause 
Due to many existing installations where the 
socket-outlets can be protected with 
fuses with higher rating than the rating of the 
socket-outlets the protection for 
pluggable equipment type A shall be an integral 
part of the equipment. 
Justification
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse. 
 
N/A 
 
Page 13 of 18 
 
Report No.: 211-2012016-000 
Attachment No. 1
 
 
IEC60065K - ATTACHMENT 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
5.3 
(A2:2010) 
Finland, Norway and Sweden 
To the end of the subclause the following is added
CLASS I 
apparatus which is intended for connection 
to the building installation wiring 
via a plug or an appliance coupler, or both and in 
addition is intended for connection 
to other apparatus or a network shall, if safety 
relies on connection to protective earth 
or if surge suppressors are connected between the 
network 
TERMINALS 
and 
ACCESSIBLE 
parts, have a marking stating that the 
apparatus must be connected to an 
earthed 
MAINS 
socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
In Finland: "Laite on liitettävä suojakoskettimilla 
varustettuun pistorasiaan" 
In Norway
: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden
: “Apparaten skall anslutas till jordat 
uttag” 
 
N/A 
5.4 
(A11:2008) 
 
Finland, Norway and Sweden 
To the end of 5.4 the following is added
CLASS I apparatus which is intended for 
connection to the building installation wiring via a 
plug or an appliance coupler, or both and in 
addition is intended for connection to other 
apparatus or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
TERMINALS and ACCESSIBLE parts, have a 
marking stating that the apparatus must be 
connected to an MAINS socket-outlet with 
protective earth. 
The marking text in the applicable countries shall 
be as follows: 
In Finland: “Laite on liitettävä 
suojamaadoituskoskettimilla varustettuun 
pistorasiaan” 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: "Apparaten skall anslutas till jordat 
uttag" 
 
N/A 
 
Page 14 of 18 
 
Report No.: 211-2012016-000 
Attachment No. 1
 
 
IEC60065K - ATTACHMENT 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
5.4.1 
(A11:2008) 
 
Norway and Sweden  
To the end of 5.4.1 (after the compliance 
statement) the following is added:  
The screen of the cable distribution system is 
normally not earthed at the entrance of the building 
and there is normally no equipotential bonding 
system within the building. Therefore the protective 
earthing of the building installation need to be 
isolated from the screen of a cable distribution 
system.  
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer.  
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in:  
“Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing 
– and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-
11)”  
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min.  
Translation to Norwegian (the Swedish text will also 
be accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr 
– og 
er tilkoplet et kabel-TV nett, kan forårsake 
brannfare. For å unngå dette skal det ved tilkopling 
av utstyret til kabel-TV nettet installeres en 
galvanisk isolator mellom utstyret og kabel-TV 
nettet.”  
 
N/A 