Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
14.4.4 
Add: High voltage isolation component insulation 
test. 
 
N/A 
14.5.1 
Delete reference to 14.5.1.3. 
 
N/A 
14.5.1.1 
Replace text with: Thermal cutouts shall comply 
with UL 873, UL 8730-2-9 or UL 60730-2-9. 
 
N/A 
14.5.1.2 
Replace text with: "Thermal links shall comply 
with UL 1020 or IEC 60691." 
 
N/A 
14.5.1.3 
Delete 
 
N/A 
14.5.2.1 
Modification: Fuse links shall comply with UL 248-
14 
 
14.5.2.2 
Delete reference to IEC 60127 and breaking 
capacity marking requirements 
 
14.5.3 
Add: As an option, a PTC thermistor may comply 
with UL 1434. Delete the 3rd and 4th paragraphs. 
 
N/A 
14.5.3A 
Add: Protective devices connected to the mains 
shall have adequate breaking capacity and 
comply with UL 873, UL 1416, UL 1417 or UL 
2111 as applicable. 
 
N/A 
14.5.4 
Reference to fuse-links is deleted 
 
N/A 
14.6.1 
Add: ―Switches and relays shall comply with UL 
1054, UL 61058-1 or UL 508 as applicable. Mains 
switch or relay shall be rated for the total current 
through the switch or relay contacts.‖ 
Replace remaining text with: ―A rating of a mains 
switch or relay, provided on a audio apparatus 
intended for commercial use, is to be equal to or 
greater than the maximum steady state current it 
controls under normal 
operating conditions except the audio output is 
adjusted to 1/3 maximum undistorted output or at 
1/3 of the manufacturer‘s rated output power, 
whichever is greater.‖ 
 
14.6.2, 
14.6.3, 
14.6.4 
deleted. 
 
N/A 
14.6.5 
Modification: A switch or relay that controls a 
mains socket-outlet shall have a rating equal to 
the rated current consumption of the apparatus 
plus the current rating of the socket-outlet. 
 
N/A 
14.6.6 
Add: A mains switch shall comply with (a), (b) or 
(c). The contacts of a mains relay shall comply 
with (a), (b) or (d). A switch that controls a mains 
receptacle shall comply with (b) and a relay that 
controls a mains receptacle shall comply with (b) 
or (d). 
 
Page 62 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
14.6.6a 
Add: Switch or relay contacts to have current 
rating equal to or greater than 1.414 times the 
inrush current of the apparatus. 
 
14.6.6b 
Add: Switch or relay to be TV rated. 
 
14.6.6c 
Add: Switch is located on the back of apparatus 
and is not operable from a remote control. 
 
14.6.6d 
Add: Relay is to be subjected to the endurance 
test. 
 
N/A 
14.6.6.1 
Add: Peak Inrush current test 
 
N/A 
14.6.6.2 
Add: Relay endurance test 
 
N/A 
14.6.7 
Add: Double pole switch controlling a.c. and d.c. 
circuits shall be suitable for the application. 
 
14.7 
Add to the end of the 2nd paragraph ―…except 
that the jointed test finger to in 9.1.1 is used to 
determine accessibility (IEC 60950, 2.8.2) and 
interlock operation (IEC 60950, 2.8.3).‖ 
 
N/A 
14.10.6 
Add: ―An apparatus intended for use with an 
external battery shall be provided with an 
overcurrent protective device in the battery-supply 
circuit.‖ 
Non-rechargeable batteries used in 
the remote controller 
N/A 
14.11 
Add: ―Component power supplies and their 
optocouplers complying with the construction and 
test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the 
test requirements on the clause.‖ 
Optocouplers bridging reinforced insulation shall 
comply with requirements for double protection as 
specified in UL 1577. 
4th paragraph reads: ―External clearances and 
creepage distances of optocouplers shall comply 
with 13.1.‖ 
 
14.12 
Replace ―IEC 61051-2‖ with ―UL 1449‖ and ―IEC 
60707‖ with ―UL 94.‖ Delete all references to ―IEC 
60151‖.  
 
15.1.1 
Add: ―Attachment plug shall have a current rating 
no less than 125% of the current drawn under 
normal operating conditions and a voltage rating 
appropriate for the rated voltage of the apparatus. 
Attachment plugs for use on more than one 
supply voltage by means of a voltage selector 
shall be rated for the voltage, which the 
apparatus is intended to be connected when it is 
shipped from the factory. Attachment plug cap 
shall be polarized when the apparatus is provided 
with a manually operated, line connected, single-
pole switch; Edison-base lampholder; or a 15 or 
20 A socket outlet.‖ 
 
Page 63 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
15.1.2 
Delete reference to ―Banana‖ plug in the Note. 
 
N/A 
15.1.3.1 
Add: ―An audio amplifier having an open-circuit 
audio output voltage not limited to 120 V that is 
permanently connected to the mains shall be 
provided with a means for connection complying 
with U.21.1.1 
–U.21.1.7 and wire-binding screws 
No. 6-32 or larger complying with U.21.3.1 
– 
U.21.3.5, or quick-connect terminals, or leads. 
Quick Connect Terminal shall comply with the 
following:  
a) Male tabs firmly mounted in place,  
b) Mating female connectors shall be provided 
with the apparatus,  
c) Strain Relief Test of Clause 16.5,  
d) Installation instructions shall be provided for 
assembly of terminal to a conductor and strain 
relief,  
e) Terminals shall be appropriate for use with the 
size and type of wire specified.‖ 
 
N/A 
15.1.3.2 
Add: "Audio amplifiers having an audio output not 
limited to 120 V that are connected to the mains 
by a flexible cord shall have suitable cord or 
provision for field installation or a receptacle for 
plug-in connections." 
 
N/A 
15.2 
Add after 3rd paragraph: ―The earthing conductor 
in a supply cord, or in an interconnecting cable 
shall have an equivalent or larger cross-sectional 
area that the current-carrying conductors in the 
supply cord or cable. With reference to earthing 
conductors, the insulation color may be green or 
green/yellow. 
 
N/A 
15.3.5 
Revise 2nd paragraph to read: ―For rated currents 
exceeding 13 A, reference is made to Article 310 
of the National Electrical Code, ANSI/NFPA 70.‖ 
Table 15 - 
Replace with: ―Nominal cross-sectional 
area AWG― and modify values. 
 
N/A 
15.4 
Add: ‖Component power supply adaptors 
complying with the construction and test 
requirements of UL1310, UL 1950 Third Edition, 
or UL 60950 are considered to fulfill the test 
requirements on the clause.‖ 
 
N/A 
16.1 
Modification: Mains supply flexible cords shall 
comply with UL 817, be marked VW-1, and have 
an ampacity not less than the current drawn by 
the apparatus. Delete references to IEC 602227, 
60245 and 60173. 
Table 17A - Add: Types of cords and cord lengths 
for various types of apparatus. 
UL approved power cord used 
Page 64 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
16.2 
An integral earthing conductor shall be at least 
the same size as the other cord conductors. 
Substitute ―IEC 60950, table 3B‖ with ―Article 400 
of the National Electrical Code‖. 
Table 18 
– Replace with ―Wire sizes of external 
flexible cords‖ Upper current limit in column 1 
increased from 16 to 30 A and ―AWG‖ wire sizes 
added. 
 
N/A 
16.3 
Add: c) Flexible cords not complying with 16.1, 
used as connection between the apparatus and 
other apparatus used in combination with it, shall 
be marked VW-1. 
 
N/A 
17.8 
Expanded to include all cart/stand parts supplied 
by the manufacturer, such as casters and 
brackets. 
Suitable assembly instructions required. Add: 
"Relevant fixing means are not required when 
installation is to be done by a skilled person." 
 
N/A 
17.10 
Add: Aluminum conductors used as internal 
wiring shall be terminated by a method capable of 
being used in the combination of metals involved 
at the connection point. 
 
N/A 
17.11 
Add: An accessory shall be investigated to 
determine that: a) The accessory, and the 
combination of the accessory and the apparatus 
shall present no hazard in the sense of this 
standard and b) The accessory is provided with 
installation instructions. 
 
17.11.1 
Add: The installation of an accessory of a skilled 
person shall be such that: a) The mechanical 
positioning is accomplished by means of tools 
normally available or by means of special tools 
provided by the organization responsible for 
providing the apparatus as part of the installation 
kit, and b) The electrical connections are made by 
using existing terminals and connections in the 
apparatus or the building wiring. 
 
N/A 
18 
Modification: Non-intrinsically protected picture 
tubes shall comply with 18.1, 18.2.2 and 18.3. 
Intrinsically protected picture tubes shall comply 
with UL 1418 or UL 61965. 
Add: ―A bulb of a picture tube having a face 
diameter of 7.5 cm or more shall be mounted in 
an enclosure. 
The enclosure shall have no opening that 
exceeds 130 mm2 unless the minor dimension of 
the opening is 10 mm or less.‖ 
 
N/A 